    Minimizing Human Tracking Error for Robotic Rehabilitation Device

    Source: Journal of Medical Devices:;2015:;volume( 009 ):;issue: 004::page 41003
    Author:
    Homich, Andrew J.
    ,
    Doerzbacher, Megan A.
    ,
    Tschantz, Eric L.
    ,
    Piazza, Stephen J.
    ,
    Hills, Everett C.
    ,
    Moore, Jason Z.
    DOI: 10.1115/1.4030275
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper explores the design of a novel robotic device for gait training and rehabilitation, a method to estimate a human's orientation within the rehabilitation device, as well as an optimal state space controller to actuate the rehabilitation device. The robotic parallel bars (RPBs) were designed to address the shortcomings of currently available assistive devices. The RPB device moves in response to a human occupant to maintain a constant distance and orientation to the human. To minimize the error in tracking the human, a complementary filter was optimized to estimate the human's orientation within the device using a magnetometer and gyroscope. Experimental measurements of complementary filter performance on a test platform show that the filter estimates orientation with an average error of 0.62 deg over a range of angular velocities from 22.5 deg/s to 180 deg/s. The RPB device response was simulated, and an optimal state space controller was implemented using a linear quadratic regulator (LQR). The controller has an average position error of 14.1 cm and an average orientation error of 14.3 deg when tracking a human, while the simulation predicted an average error of 10.5 cm and 5.6 deg. The achieved level of accuracy in following a human user is sufficiently sensitive for the RPB device to conduct more advanced, realistic gait training and rehabilitation techniques for mobility impaired patients able to safely support their body weight with their legs and arms.
    • Download: (1.705Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Minimizing Human Tracking Error for Robotic Rehabilitation Device

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/159180
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorHomich, Andrew J.
    contributor authorDoerzbacher, Megan A.
    contributor authorTschantz, Eric L.
    contributor authorPiazza, Stephen J.
    contributor authorHills, Everett C.
    contributor authorMoore, Jason Z.
    date accessioned2017-05-09T01:21:55Z
    date available2017-05-09T01:21:55Z
    date issued2015
    identifier issn1932-6181
    identifier othermed_009_04_041003.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/159180
    description abstractThis paper explores the design of a novel robotic device for gait training and rehabilitation, a method to estimate a human's orientation within the rehabilitation device, as well as an optimal state space controller to actuate the rehabilitation device. The robotic parallel bars (RPBs) were designed to address the shortcomings of currently available assistive devices. The RPB device moves in response to a human occupant to maintain a constant distance and orientation to the human. To minimize the error in tracking the human, a complementary filter was optimized to estimate the human's orientation within the device using a magnetometer and gyroscope. Experimental measurements of complementary filter performance on a test platform show that the filter estimates orientation with an average error of 0.62 deg over a range of angular velocities from 22.5 deg/s to 180 deg/s. The RPB device response was simulated, and an optimal state space controller was implemented using a linear quadratic regulator (LQR). The controller has an average position error of 14.1 cm and an average orientation error of 14.3 deg when tracking a human, while the simulation predicted an average error of 10.5 cm and 5.6 deg. The achieved level of accuracy in following a human user is sufficiently sensitive for the RPB device to conduct more advanced, realistic gait training and rehabilitation techniques for mobility impaired patients able to safely support their body weight with their legs and arms.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleMinimizing Human Tracking Error for Robotic Rehabilitation Device
    typeJournal Paper
    journal volume9
    journal issue4
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4030275
    journal fristpage41003
    journal lastpage41003
    identifier eissn1932-619X
    treeJournal of Medical Devices:;2015:;volume( 009 ):;issue: 004
    contenttypeFulltext