    Docking Robustness of Patient Specific Surgical Guides for Joint Replacement Surgery

    Source: Journal of Mechanical Design:;2015:;volume( 137 ):;issue: 006::page 62301
    Author:
    Mattheijer, Joost
    ,
    Herder, Just L.
    ,
    Tuijthof, Gabriأ«lle J. M.
    ,
    Valstar, Edward R.
    DOI: 10.1115/1.4029665
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: In joint replacement surgery, patient specific surgical guides (PSSGs) are used for accurate alignment of implant components. PSSGs are designed preoperatively to have a geometric fit with the patient's bone such that the incorporated guidance for drilling and cutting is instantly aligned. The surgeon keeps the PSSG in position with a pushing force, and it is essential that this position is maintained while drilling or cutting. Hence, the influence of the location and direction of the pushing force should be minimal. The extent that the pushing force may vary is what we refer to as docking robustness. In this article, we present a docking robustness framework comprising the following quantitative measures and graphical tool. Contact efficiency خ·c is used for the quantification of the selected bone–guide contact. Guide efficiency خ·g is used for the quantification of the whole guide including an application surface whereon the surgeon can push. Robustness maps are used to find a robust location for the application surface based on gradient colors. Robustness R is a measure indicating what angular deviation is minimally allowed at the worst point on the application surface. The robustness framework is utilized in an optimization of PSSG dimensions for the distal femur. This optimization shows that 12 contacts already result in a relatively high contact efficiency of 0.74 آ±â€‰0.02 (where the maximum of 1.00 is obtained when the guide is designed for full bone–guide contact). Six contacts seem to be insufficient as the obtained contact efficiency is only 0.18 آ±â€‰0.02.
    • Download: (3.819Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Docking Robustness of Patient Specific Surgical Guides for Joint Replacement Surgery

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/158838
    Collections
    • Journal of Mechanical Design

    Show full item record

    contributor authorMattheijer, Joost
    contributor authorHerder, Just L.
    contributor authorTuijthof, Gabriأ«lle J. M.
    contributor authorValstar, Edward R.
    date accessioned2017-05-09T01:20:57Z
    date available2017-05-09T01:20:57Z
    date issued2015
    identifier issn1050-0472
    identifier othermd_137_06_062301.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/158838
    description abstractIn joint replacement surgery, patient specific surgical guides (PSSGs) are used for accurate alignment of implant components. PSSGs are designed preoperatively to have a geometric fit with the patient's bone such that the incorporated guidance for drilling and cutting is instantly aligned. The surgeon keeps the PSSG in position with a pushing force, and it is essential that this position is maintained while drilling or cutting. Hence, the influence of the location and direction of the pushing force should be minimal. The extent that the pushing force may vary is what we refer to as docking robustness. In this article, we present a docking robustness framework comprising the following quantitative measures and graphical tool. Contact efficiency خ·c is used for the quantification of the selected bone–guide contact. Guide efficiency خ·g is used for the quantification of the whole guide including an application surface whereon the surgeon can push. Robustness maps are used to find a robust location for the application surface based on gradient colors. Robustness R is a measure indicating what angular deviation is minimally allowed at the worst point on the application surface. The robustness framework is utilized in an optimization of PSSG dimensions for the distal femur. This optimization shows that 12 contacts already result in a relatively high contact efficiency of 0.74 آ±â€‰0.02 (where the maximum of 1.00 is obtained when the guide is designed for full bone–guide contact). Six contacts seem to be insufficient as the obtained contact efficiency is only 0.18 آ±â€‰0.02.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDocking Robustness of Patient Specific Surgical Guides for Joint Replacement Surgery
    typeJournal Paper
    journal volume137
    journal issue6
    journal titleJournal of Mechanical Design
    identifier doi10.1115/1.4029665
    journal fristpage62301
    journal lastpage62301
    identifier eissn1528-9001
    treeJournal of Mechanical Design:;2015:;volume( 137 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian