Effect of Channel Confinement on Mixed Convective Flow Past an Equilateral Triangular CylinderSource: Journal of Heat Transfer:;2015:;volume( 137 ):;issue: 012::page 121013DOI: 10.1115/1.4030960Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The present work investigates the mixed convective flow and heat transfer characteristics past a triangular cylinder placed symmetrically in a vertical channel. At a representative Reynolds number, Re = 100, simulations are carried out for the blockage ratios خ²=1/3,1/4, and 1/6. Effect of aiding and opposing buoyancy is brought about by varying the Richardson number in the range 1.0≤Ri≤1.0. At a blockage ratio of 1/3, suppression of vortex shedding is found at Ri = 1, whereas von Kأ،rmأ،n vortex street is seen both at خ²=1/4 and 1/6, respectively. This is the first time that such behavior of blockage ratio past a triangular cylinder in the present flow configuration is reported. Drag coefficient increases progressively with increasing Ri and a slightly higher value is noticed at خ²=1/3. For all خ², heat transfer increases with increasing Ri. Flattening of Nuavg –Ri curve beyond Ri>0.75 is observed at خ²=1/3.
|
Collections
Show full item record
| contributor author | Varma, Nitish | |
| contributor author | Dulhani, Jay P. | |
| contributor author | Dalal, Amaresh | |
| contributor author | Sarkar, Sandip | |
| contributor author | Ganguly, Suvankar | |
| date accessioned | 2017-05-09T01:20:06Z | |
| date available | 2017-05-09T01:20:06Z | |
| date issued | 2015 | |
| identifier issn | 0022-1481 | |
| identifier other | ht_137_12_121013.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/158606 | |
| description abstract | The present work investigates the mixed convective flow and heat transfer characteristics past a triangular cylinder placed symmetrically in a vertical channel. At a representative Reynolds number, Re = 100, simulations are carried out for the blockage ratios خ²=1/3,1/4, and 1/6. Effect of aiding and opposing buoyancy is brought about by varying the Richardson number in the range 1.0≤Ri≤1.0. At a blockage ratio of 1/3, suppression of vortex shedding is found at Ri = 1, whereas von Kأ،rmأ،n vortex street is seen both at خ²=1/4 and 1/6, respectively. This is the first time that such behavior of blockage ratio past a triangular cylinder in the present flow configuration is reported. Drag coefficient increases progressively with increasing Ri and a slightly higher value is noticed at خ²=1/3. For all خ², heat transfer increases with increasing Ri. Flattening of Nuavg –Ri curve beyond Ri>0.75 is observed at خ²=1/3. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Effect of Channel Confinement on Mixed Convective Flow Past an Equilateral Triangular Cylinder | |
| type | Journal Paper | |
| journal volume | 137 | |
| journal issue | 12 | |
| journal title | Journal of Heat Transfer | |
| identifier doi | 10.1115/1.4030960 | |
| journal fristpage | 121013 | |
| journal lastpage | 121013 | |
| identifier eissn | 1528-8943 | |
| tree | Journal of Heat Transfer:;2015:;volume( 137 ):;issue: 012 | |
| contenttype | Fulltext |