Show simple item record

contributor authorWu, John Z.
contributor authorSinsel, Erik W.
contributor authorZhao, Kristin D.
contributor authorAn, Kai
contributor authorBuczek, Frank L.
date accessioned2017-05-09T01:15:21Z
date available2017-05-09T01:15:21Z
date issued2015
identifier issn0148-0731
identifier otherbio_137_08_084501.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/157171
description abstractDynamic loading on articular joints is essential for the evaluation of the risk of the articulation degeneration associated with occupational activities. In the current study, we analyzed the dynamic constraint loading for the thumb during pipetting. The constraint loading is considered as the loading that has to be carried by the connective tissues of the joints (i.e., the cartilage layer and the ligaments) to maintain the kinematic constraints of the system. The joint loadings are solved using a classic freebody approach, using the external loading and muscle forces, which were obtained in an inverse dynamic approach combined with an optimization procedure in anybody. The constraint forces in the thumb joint obtained in the current study are compared with those obtained in the pinch and grasp tests in a previous study (Cooney and Chao, 1977, “Biomechanical Analysis of Static Forces in the Thumb During Hand Function,â€‌ J. Bone Joint Surg. Am., 59(1), pp. 27–36). The maximal compression force during pipetting is approximately 83% and 60% greater than those obtained in the tip pinch and key pinch, respectively, while substantially smaller than that obtained during grasping. The maximal lateral shear force is approximately six times, 32 times, and 90% greater than those obtained in the tip pinch, key pinch, and grasp, respectively. The maximal dorsal shear force during pipetting is approximately 3.2 and 1.4 times greater than those obtained in the tip pinch and key pinch, respectively, while substantially smaller than that obtained during grasping. Our analysis indicated that the thumb joints are subjected to repetitive, intensive loading during pipetting, compared to other daily activities.
publisherThe American Society of Mechanical Engineers (ASME)
titleAnalysis of the Constraint Joint Loading in the Thumb During Pipetting
typeJournal Paper
journal volume137
journal issue8
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4030311
journal fristpage84501
journal lastpage84501
identifier eissn1528-8951
treeJournal of Biomechanical Engineering:;2015:;volume( 137 ):;issue: 008