    Infarcted Left Ventricles Have Stiffer Material Properties and Lower Stiffness Variation: Three Dimensional Echo Based Modeling to Quantify In Vivo Ventricle Material Properties

    Source: Journal of Biomechanical Engineering:;2015:;volume( 137 ):;issue: 008::page 81005
    Author:
    Fan, Longling
    ,
    Yao, Jing
    ,
    Yang, Chun
    ,
    Tang, Dalin
    ,
    Xu, Di
    DOI: 10.1115/1.4030668
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Methods to quantify ventricle material properties noninvasively using in vivo data are of great important in clinical applications. An ultrasound echobased computational modeling approach was proposed to quantify left ventricle (LV) material properties, curvature, and stress/strain conditions and find differences between normal LV and LV with infarct. Echo image data were acquired from five patients with myocardial infarction (IGroup) and five healthy volunteers as control (HGroup). Finite element models were constructed to obtain ventricle stress and strain conditions. Material stiffening and softening were used to model ventricle active contraction and relaxation. Systolic and diastolic material parameter values were obtained by adjusting the models to match echo volume data. Young's modulus (YM) value was obtained for each material stress–strain curve for easy comparison. LV wall thickness, circumferential and longitudinal curvatures (Cand Lcurvature), material parameter values, and stress/strain values were recorded for analysis. Using the mean value of HGroup as the base value, at enddiastole, IGroup mean YM value for the fiber direction stress–strain curve was 54% stiffer than that of HGroup (136.24 kPa versus 88.68 kPa). At endsystole, the mean YM values from the two groups were similar (175.84 kPa versus 200.2 kPa). More interestingly, HGroup endsystole mean YM was 126% higher that its enddiastole value, while IGroup endsystole mean YM was only 29% higher that its enddiastole value. This indicated that HGroup had much greater systole–diastole material stiffness variations. At beginningofejection (BE), LV ejection fraction (LVEF) showed positive correlation with Ccurvature, stress, and strain, and negative correlation with LV volume, respectively. At beginningoffilling (BF), LVEF showed positive correlation with Ccurvature and strain, but negative correlation with stress and LV volume, respectively. Using averaged values of two groups at BE, IGroup stress, strain, and wall thickness were 32%, 29%, and 18% lower (thinner), respectively, compared to those of HGroup. Lcurvature from IGroup was 61% higher than that from HGroup. Difference in Ccurvature between the two groups was not statistically significant. Our results indicated that our modeling approach has the potential to determine in vivo ventricle material properties, which in turn could lead to methods to infer presence of infarct from LV contractibility and material stiffness variations. Quantitative differences in LV volume, curvatures, stress, strain, and wall thickness between the two groups were provided.
    • Download: (2.616Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Infarcted Left Ventricles Have Stiffer Material Properties and Lower Stiffness Variation: Three Dimensional Echo Based Modeling to Quantify In Vivo Ventricle Material Properties

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/157160
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorFan, Longling
    contributor authorYao, Jing
    contributor authorYang, Chun
    contributor authorTang, Dalin
    contributor authorXu, Di
    date accessioned2017-05-09T01:15:19Z
    date available2017-05-09T01:15:19Z
    date issued2015
    identifier issn0148-0731
    identifier otherbio_137_08_081005.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/157160
    description abstractMethods to quantify ventricle material properties noninvasively using in vivo data are of great important in clinical applications. An ultrasound echobased computational modeling approach was proposed to quantify left ventricle (LV) material properties, curvature, and stress/strain conditions and find differences between normal LV and LV with infarct. Echo image data were acquired from five patients with myocardial infarction (IGroup) and five healthy volunteers as control (HGroup). Finite element models were constructed to obtain ventricle stress and strain conditions. Material stiffening and softening were used to model ventricle active contraction and relaxation. Systolic and diastolic material parameter values were obtained by adjusting the models to match echo volume data. Young's modulus (YM) value was obtained for each material stress–strain curve for easy comparison. LV wall thickness, circumferential and longitudinal curvatures (Cand Lcurvature), material parameter values, and stress/strain values were recorded for analysis. Using the mean value of HGroup as the base value, at enddiastole, IGroup mean YM value for the fiber direction stress–strain curve was 54% stiffer than that of HGroup (136.24 kPa versus 88.68 kPa). At endsystole, the mean YM values from the two groups were similar (175.84 kPa versus 200.2 kPa). More interestingly, HGroup endsystole mean YM was 126% higher that its enddiastole value, while IGroup endsystole mean YM was only 29% higher that its enddiastole value. This indicated that HGroup had much greater systole–diastole material stiffness variations. At beginningofejection (BE), LV ejection fraction (LVEF) showed positive correlation with Ccurvature, stress, and strain, and negative correlation with LV volume, respectively. At beginningoffilling (BF), LVEF showed positive correlation with Ccurvature and strain, but negative correlation with stress and LV volume, respectively. Using averaged values of two groups at BE, IGroup stress, strain, and wall thickness were 32%, 29%, and 18% lower (thinner), respectively, compared to those of HGroup. Lcurvature from IGroup was 61% higher than that from HGroup. Difference in Ccurvature between the two groups was not statistically significant. Our results indicated that our modeling approach has the potential to determine in vivo ventricle material properties, which in turn could lead to methods to infer presence of infarct from LV contractibility and material stiffness variations. Quantitative differences in LV volume, curvatures, stress, strain, and wall thickness between the two groups were provided.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleInfarcted Left Ventricles Have Stiffer Material Properties and Lower Stiffness Variation: Three Dimensional Echo Based Modeling to Quantify In Vivo Ventricle Material Properties
    typeJournal Paper
    journal volume137
    journal issue8
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4030668
    journal fristpage81005
    journal lastpage81005
    identifier eissn1528-8951
    treeJournal of Biomechanical Engineering:;2015:;volume( 137 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian