| contributor author | Marie Bailey, Ann | |
| contributor author | Christopher, John J. | |
| contributor author | Salzar, Robert S. | |
| contributor author | Brozoski, Frederick | |
| date accessioned | 2017-05-09T01:15:09Z | |
| date available | 2017-05-09T01:15:09Z | |
| date issued | 2015 | |
| identifier issn | 0148-0731 | |
| identifier other | bio_137_05_051009.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/157116 | |
| description abstract | Response of the human body to highrate vertical loading, such as military vehicle underbody blast (UBB), is not well understood because of the chaotic nature of such events. The purpose of this research was to compare the response of postmortem human surrogates (PMHS) and the HybridIII anthropomorphic test device (ATD) to simulated UBB loading ranging from 100 to 860 g seat and floor acceleration. Data from 13 whole body PMHS tests were used to create response corridors for vertical loading conditions for the pelvis, T1, head, femur, and tibia; these responses were compared to HybridIII responses under matched loading conditions. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Comparison of Hybrid III and Postmortem Human Surrogate Response to Simulated Underbody Blast Loading | |
| type | Journal Paper | |
| journal volume | 137 | |
| journal issue | 5 | |
| journal title | Journal of Biomechanical Engineering | |
| identifier doi | 10.1115/1.4029981 | |
| journal fristpage | 51009 | |
| journal lastpage | 51009 | |
| identifier eissn | 1528-8951 | |
| tree | Journal of Biomechanical Engineering:;2015:;volume( 137 ):;issue: 005 | |
| contenttype | Fulltext | |