YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Comparison Between Healthy and Reduced Hand Function Using Ranges of Motion and a Weighted Fingertip Space Model

    Source: Journal of Biomechanical Engineering:;2015:;volume( 137 ):;issue: 004::page 41003
    Author:
    Leitkam, Samuel T.
    ,
    Reid Bush, Tamara
    DOI: 10.1115/1.4029215
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Detection and quantification of changes in hand function are important for patients with loss of function and clinicians who are treating them. A recently developed model, the weighted fingertip space (WFS) quantifies the hand function of individuals in threedimensional space and applies kinematic weighting parameters to identify regions of reachable space with high and low hand function. The goal of this research was to use the WFS model to compare and contrast the functional abilities of healthy individuals with the abilities of individuals with reduced functionality due to arthritis (RFA). Twenty two individuals with no reported issues with hand function and 21 individuals with arthritis affecting the hand were included in the research. Functional models were calculated from the ranges of motion and hand dimension data for each individual. Each model showed the volume of reachable space for each fingertip of each hand, the number of ways to reach a point in space, the range of fingertip orientations possible at each point, and the range of possible force application directions (FADs) at each point. In addition, two group models were developed that showed how many individuals in both the healthy and RFA groups were able to reach the same points in space. The results showed differences between the two groups for the range of motion (ROM) measurements, the individual model calculations, and the group models. The ROM measurements showed significant differences for the joints of the thumb, extension of the nonthumb metacarpophalangeal (MCP) joints, and flexion of the distal interphalangeal (DIP) joints. Comparing the models, the two groups qualitatively showed similar patterns of functional measures in space, but with the RFA group able to reach a smaller volume of space. Quantitatively, the RFA group showed trends of smaller values for all of the calculated functional weighting parameters and significantly smaller reachable volume for all of the fingers. The group models showed that all healthy individuals were able to reach an overlapping space, while 18 of 21 RFA individuals were able to reach similar spaces. Combined, the results showed that the WFS model presents the abilities of the hand in ways that can be quantitatively and qualitatively compared. Thus, the potential of this hand model is that it could be used to assess and document the changes that occur in hand function due to rehabilitation or surgery, or as a guide to determine areas most accessible by various populations.
    • Download: (2.777Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Comparison Between Healthy and Reduced Hand Function Using Ranges of Motion and a Weighted Fingertip Space Model

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/157097
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorLeitkam, Samuel T.
    contributor authorReid Bush, Tamara
    date accessioned2017-05-09T01:15:05Z
    date available2017-05-09T01:15:05Z
    date issued2015
    identifier issn0148-0731
    identifier otherbio_137_04_041003.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/157097
    description abstractDetection and quantification of changes in hand function are important for patients with loss of function and clinicians who are treating them. A recently developed model, the weighted fingertip space (WFS) quantifies the hand function of individuals in threedimensional space and applies kinematic weighting parameters to identify regions of reachable space with high and low hand function. The goal of this research was to use the WFS model to compare and contrast the functional abilities of healthy individuals with the abilities of individuals with reduced functionality due to arthritis (RFA). Twenty two individuals with no reported issues with hand function and 21 individuals with arthritis affecting the hand were included in the research. Functional models were calculated from the ranges of motion and hand dimension data for each individual. Each model showed the volume of reachable space for each fingertip of each hand, the number of ways to reach a point in space, the range of fingertip orientations possible at each point, and the range of possible force application directions (FADs) at each point. In addition, two group models were developed that showed how many individuals in both the healthy and RFA groups were able to reach the same points in space. The results showed differences between the two groups for the range of motion (ROM) measurements, the individual model calculations, and the group models. The ROM measurements showed significant differences for the joints of the thumb, extension of the nonthumb metacarpophalangeal (MCP) joints, and flexion of the distal interphalangeal (DIP) joints. Comparing the models, the two groups qualitatively showed similar patterns of functional measures in space, but with the RFA group able to reach a smaller volume of space. Quantitatively, the RFA group showed trends of smaller values for all of the calculated functional weighting parameters and significantly smaller reachable volume for all of the fingers. The group models showed that all healthy individuals were able to reach an overlapping space, while 18 of 21 RFA individuals were able to reach similar spaces. Combined, the results showed that the WFS model presents the abilities of the hand in ways that can be quantitatively and qualitatively compared. Thus, the potential of this hand model is that it could be used to assess and document the changes that occur in hand function due to rehabilitation or surgery, or as a guide to determine areas most accessible by various populations.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleComparison Between Healthy and Reduced Hand Function Using Ranges of Motion and a Weighted Fingertip Space Model
    typeJournal Paper
    journal volume137
    journal issue4
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4029215
    journal fristpage41003
    journal lastpage41003
    identifier eissn1528-8951
    treeJournal of Biomechanical Engineering:;2015:;volume( 137 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian