Simulation and Measurement of Through–Wall Residual Stresses in a Structural Weld Overlaid Pressurizer NozzleSource: Journal of Pressure Vessel Technology:;2014:;volume( 136 ):;issue: 005::page 51401Author:Marlette, Stephen
,
Freyer, Paula
,
Smith, Michael
,
Goodfellow, Andrew
,
Pitoiset, Xavier
,
Voigt, Bradley
,
Rishel, Rick
,
Kingston, Ed
DOI: 10.1115/1.4024657Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Full structural weld overlays (FSWOLs) have been used extensively as a repair/mitigation technique for primary water stress corrosion cracking in pressurizer nozzle dissimilar metal (DM) welds. To support an approved FSWOL design and safety submission for British Energy pressurized water reactor (PWR) nozzles, an indepth evaluation was performed to assess the effects of a FSWOL on the through wall residual stress distribution in safety/relief pressurizer nozzles. Two safety/relief pressurizer nozzle mockups were fabricated based on British Energy’s PWR nozzle design. One mockup included the nozzle to safeend DM weld and the safeend to stainless steel weld, while the second mockup included the DM weld, the stainless steel weld, and a Westinghouse designed structural weld overlay. The mockups were fabricated utilizing materials and techniques that represented the plant specific nozzles as closely as possible and detailed welding parameters were recorded during fabrication. All welds were subsequently nondestructively evaluated (NDE). A thorough review of the detailed fabrication records and the NDE results was performed and several circumferential positions were selected on each mockup for subsequent residual stress measurement. The through wall residual stress profiles were experimentally measured through the DM weld centerline at the selected circumferential positions using both the deephole drilling (DHD) and incremental deephole drilling (iDHD) measurement techniques. In addition to experimental residual stress measurements, the throughwall residual stress profiles were simulated using a 2D axisymmetric ansys™ finite element (FE) model. The model utilized the application of temperature constraints on the weld elements to simulate the thermal welding cycle which greatly simplified the simulation as compared with detailed heat source modeling methods. Kinematic strain hardening was used for material modeling of the weld and base metals. A range of residual weld stress profiles was calculated by varying the time at which the temperature constraints were applied to the model. The simulation results were compared with the measurement results. It was found that the effects of the FSWOL were principally threefold. Specifically, the FSWOL causes a much deeper compressive stress field, i.e., the overlay shifts tension out toward the outside diameter (OD) surface. Furthermore, the FSWOL reduces tension in the underlying dissimilar metal weld, and finally, the FSWOL causes higher peak compressive and tensile residual stresses, both of which move deeper into the nozzle wall after the overlay is applied. Relatively good agreement was observed between the FE results and the measurements results.
|
Collections
Show full item record
| contributor author | Marlette, Stephen | |
| contributor author | Freyer, Paula | |
| contributor author | Smith, Michael | |
| contributor author | Goodfellow, Andrew | |
| contributor author | Pitoiset, Xavier | |
| contributor author | Voigt, Bradley | |
| contributor author | Rishel, Rick | |
| contributor author | Kingston, Ed | |
| date accessioned | 2017-05-09T01:12:08Z | |
| date available | 2017-05-09T01:12:08Z | |
| date issued | 2014 | |
| identifier issn | 0094-9930 | |
| identifier other | pvt_136_05_051401.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/156192 | |
| description abstract | Full structural weld overlays (FSWOLs) have been used extensively as a repair/mitigation technique for primary water stress corrosion cracking in pressurizer nozzle dissimilar metal (DM) welds. To support an approved FSWOL design and safety submission for British Energy pressurized water reactor (PWR) nozzles, an indepth evaluation was performed to assess the effects of a FSWOL on the through wall residual stress distribution in safety/relief pressurizer nozzles. Two safety/relief pressurizer nozzle mockups were fabricated based on British Energy’s PWR nozzle design. One mockup included the nozzle to safeend DM weld and the safeend to stainless steel weld, while the second mockup included the DM weld, the stainless steel weld, and a Westinghouse designed structural weld overlay. The mockups were fabricated utilizing materials and techniques that represented the plant specific nozzles as closely as possible and detailed welding parameters were recorded during fabrication. All welds were subsequently nondestructively evaluated (NDE). A thorough review of the detailed fabrication records and the NDE results was performed and several circumferential positions were selected on each mockup for subsequent residual stress measurement. The through wall residual stress profiles were experimentally measured through the DM weld centerline at the selected circumferential positions using both the deephole drilling (DHD) and incremental deephole drilling (iDHD) measurement techniques. In addition to experimental residual stress measurements, the throughwall residual stress profiles were simulated using a 2D axisymmetric ansys™ finite element (FE) model. The model utilized the application of temperature constraints on the weld elements to simulate the thermal welding cycle which greatly simplified the simulation as compared with detailed heat source modeling methods. Kinematic strain hardening was used for material modeling of the weld and base metals. A range of residual weld stress profiles was calculated by varying the time at which the temperature constraints were applied to the model. The simulation results were compared with the measurement results. It was found that the effects of the FSWOL were principally threefold. Specifically, the FSWOL causes a much deeper compressive stress field, i.e., the overlay shifts tension out toward the outside diameter (OD) surface. Furthermore, the FSWOL reduces tension in the underlying dissimilar metal weld, and finally, the FSWOL causes higher peak compressive and tensile residual stresses, both of which move deeper into the nozzle wall after the overlay is applied. Relatively good agreement was observed between the FE results and the measurements results. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Simulation and Measurement of Through–Wall Residual Stresses in a Structural Weld Overlaid Pressurizer Nozzle | |
| type | Journal Paper | |
| journal volume | 136 | |
| journal issue | 5 | |
| journal title | Journal of Pressure Vessel Technology | |
| identifier doi | 10.1115/1.4024657 | |
| journal fristpage | 51401 | |
| journal lastpage | 51401 | |
| identifier eissn | 1528-8978 | |
| tree | Journal of Pressure Vessel Technology:;2014:;volume( 136 ):;issue: 005 | |
| contenttype | Fulltext |