A New Laparoscopic Morcellator Using an Actuated Wire Mesh and BagSource: Journal of Medical Devices:;2014:;volume( 008 ):;issue: 001::page 11009Author:Isakov, Alexander
,
Murdaugh, Kimberly M.
,
Burke, William C.
,
Zimmerman, Sloan
,
Roche, Ellen
,
Holland, Donal
,
Einarsson, Jon I.
,
Walsh, Conor J.
DOI: 10.1115/1.4026294Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Laparoscopic morcellation is a technique used in gynecological surgeries such as hysterectomy and myomectomy to remove uteri and uterine fibroids (leiomyomas) through a small abdominal incision. Current morcellators use blades or bipolar energy to cut tissue into small pieces that are then removed through laparoscopic ports in a piecewise manner. These existing approaches have several limitations; (1) they are time consuming as the tissue must be manually moved over the devices during the cutting step and removal is piecewise, (2) they can lead to accidental damage to surrounding healthy tissue inside the body and (3) they do not provide safe containment of tissue during the morcellation process which can lead to seeding (spreading and regrowth) of benign or potentially cancerous tissue. This paper describes a laparoscopic morcellator that overcomes these limitations through a new design that is based on an enclosed, motoractuated mesh that applies only an inwarddirected cutting force to the tissue after it has been loaded into the protective mesh and bag. The deterministic design approach that led to this concept is presented along with the detailed electromechanical design. The prototype is tested on soft vegetables and an animal model to demonstrate successful morcellation and how the device would be compatible with current clinical practice. Results show that the time required to morcellate with the new device for a set of tests on animal tissue is relatively uniform across samples with widely varying parameters. Including tissue manipulation and extraction time, the new device is shown to have an improvement in terms of speed over current morcellators. The mean time for cutting animal tissue ranging from 100 g to 360 g was 30 s with small variations due to initial conditions. The time for cutting is expected to remain approximately constant as tissue size increases. There is also minimal risk of the protective bag ripping due to the inwardcutting action of the mesh, thereby potentially significantly reducing the risk of seeding during clinical procedures; thus, further increasing patient safety. Finally, this design may be applicable to other procedures involving removal of tissue in nongynecologic surgeries, such as full or partial kidney or spleen removal.
|
Collections
Show full item record
| contributor author | Isakov, Alexander | |
| contributor author | Murdaugh, Kimberly M. | |
| contributor author | Burke, William C. | |
| contributor author | Zimmerman, Sloan | |
| contributor author | Roche, Ellen | |
| contributor author | Holland, Donal | |
| contributor author | Einarsson, Jon I. | |
| contributor author | Walsh, Conor J. | |
| date accessioned | 2017-05-09T01:11:02Z | |
| date available | 2017-05-09T01:11:02Z | |
| date issued | 2014 | |
| identifier issn | 1932-6181 | |
| identifier other | med_008_01_011009.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/155806 | |
| description abstract | Laparoscopic morcellation is a technique used in gynecological surgeries such as hysterectomy and myomectomy to remove uteri and uterine fibroids (leiomyomas) through a small abdominal incision. Current morcellators use blades or bipolar energy to cut tissue into small pieces that are then removed through laparoscopic ports in a piecewise manner. These existing approaches have several limitations; (1) they are time consuming as the tissue must be manually moved over the devices during the cutting step and removal is piecewise, (2) they can lead to accidental damage to surrounding healthy tissue inside the body and (3) they do not provide safe containment of tissue during the morcellation process which can lead to seeding (spreading and regrowth) of benign or potentially cancerous tissue. This paper describes a laparoscopic morcellator that overcomes these limitations through a new design that is based on an enclosed, motoractuated mesh that applies only an inwarddirected cutting force to the tissue after it has been loaded into the protective mesh and bag. The deterministic design approach that led to this concept is presented along with the detailed electromechanical design. The prototype is tested on soft vegetables and an animal model to demonstrate successful morcellation and how the device would be compatible with current clinical practice. Results show that the time required to morcellate with the new device for a set of tests on animal tissue is relatively uniform across samples with widely varying parameters. Including tissue manipulation and extraction time, the new device is shown to have an improvement in terms of speed over current morcellators. The mean time for cutting animal tissue ranging from 100 g to 360 g was 30 s with small variations due to initial conditions. The time for cutting is expected to remain approximately constant as tissue size increases. There is also minimal risk of the protective bag ripping due to the inwardcutting action of the mesh, thereby potentially significantly reducing the risk of seeding during clinical procedures; thus, further increasing patient safety. Finally, this design may be applicable to other procedures involving removal of tissue in nongynecologic surgeries, such as full or partial kidney or spleen removal. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | A New Laparoscopic Morcellator Using an Actuated Wire Mesh and Bag | |
| type | Journal Paper | |
| journal volume | 8 | |
| journal issue | 1 | |
| journal title | Journal of Medical Devices | |
| identifier doi | 10.1115/1.4026294 | |
| journal fristpage | 11009 | |
| journal lastpage | 11009 | |
| identifier eissn | 1932-619X | |
| tree | Journal of Medical Devices:;2014:;volume( 008 ):;issue: 001 | |
| contenttype | Fulltext |