contributor authorNguyen, Hung
contributor authorWang, Shoubo
contributor authorMohan, Ram S.
contributor authorShoham, Ovadia
contributor authorKouba, Gene
date accessioned2017-05-09T01:07:06Z
date available2017-05-09T01:07:06Z
date issued2014
identifier issn0195-0738
identifier otherjert_136_02_022902.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/154552
description abstractEven though there have been several studies conducted by the industry on the use of different inlet devices for gas–liquid separation, there have been limited laboratory and field evaluations on the use of external piping configurations as flow conditioning devices upstream of a separator inlet. The results of a systematic study of droplet deposition and coalescence in curved pipe and pipe fittings are reported in this paper. A facility has been designed consisting of two main test sections: a fixed horizontal straight pipe section and an interchangeable 180 deg return pipe section (or curved pipe section) of the same length. Both inlet and outlet to the 180 deg return are horizontal, but the plane of the 180 deg return pipe section can pivot about the axis of the inlet horizontal pipe to an angle as much as 10 deg downwards allowing downward flow in the return section. Various pipe fittings of different radius of curvature can be installed for comparison in the 180 deg return. Fittings evaluated in this study included: 180 deg pipe bend, short elbow bend (with standard radius of curvature of 1.5D), long elbow bend (with custom radius of curvature of 6D), target tee bend, and cushion tee bend. Experiments have been carried out using water and air, and varying gas velocities and liquid loadings. In order to compare the performance of geometries, Droplet Deposition Fractions (DDF) were measured in the horizontal straight pipe section and in the 180 deg return pipe section as a measure of coalescence efficiency. The results demonstrate that higher DDF occurs for curved fittings as compared to the straight pipe section. The short elbow bend has approximately 10% DDF higher, whereas long elbow bend along with 180 deg pipe bend perform better (by 15–20% DDF) than straight pipe. It was found that the cushion tee and target tee bends can coalesce droplets at lower gas velocities but break up droplets at higher gas velocities. Additionally, no significant differences between DDF's in three different inclination angles of a curved pipe were observed. It can be concluded that 180 deg pipe bend or two 6D long radius elbow bend can serve as a droplet coalescer; a pair of cushion tees or target tees can also work as coalescers at low kinetic energy but as atomizers at high kinetic energy.
publisherThe American Society of Mechanical Engineers (ASME)
titleExperimental Investigations of Droplet Deposition and Coalescence in Curved Pipes
typeJournal Paper
journal volume136
journal issue2
journal titleJournal of Energy Resources Technology
identifier doi10.1115/1.4026916
journal fristpage22902
journal lastpage22902
identifier eissn1528-8994
treeJournal of Energy Resources Technology:;2014:;volume( 136 ):;issue: 002
contenttypeFulltext