YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Ultrasound Assessment of Ex Vivo Lung Tissue Properties Using a Fluid Filled Negative Pressure Bath

    Source: Journal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 007::page 74504
    Author:
    Duenwald
    ,
    Bates, Melissa L.
    ,
    Cortes, Sonia Y.
    ,
    Eldridge, Marlowe W.
    ,
    Vanderby, Ray
    DOI: 10.1115/1.4027611
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A relationship between tendon stress and strain and ultrasonic echo intensity has previously been defined in tendons, demonstrating a correlation between tissue stiffness and echo intensity. An analogous relationship between volumedependent pressure changes and echo intensity changes in inflating lungs would indicate a correlation between lung compliance and echo intensity. Lung compliance is an important metric to diagnose pathologies which affect lung tissue mechanics, such as emphysema and cystic fibrosis. The goal of this study is to demonstrate a correlation between ultrasound echo intensity and lung tissue mechanics in an ex vivo model using a fluidfilled negative pressure bath design which provides a controlled environment for ultrasonic and mechanical measurements. Lungs from 4 male SpragueDawley rats were removed and mechanically tested via inflation and deflation in a negative pressure chamber filled with hetastarch. Specific volumes (1, 2, 3, and 4 mL) were removed from the chamber using a syringe to create negative pressure, which resulted in lung inflation. A pressure transducer recorded the pressure around the lungs. From these data, lung compliance was calculated. Ultrasound images were captured through the chamber wall to determine echo intensity (grayscale brightness in the ultrasound image), which was then related to mechanical parameters. Ultrasound images of the lung were successfully captured through the chamber wall with sufficient resolution to deduce echo intensity changes in the lung tissue. Echo intensity (0–255 scale) increased with volumetric changes (18.4 آ±â€‰5.5, 22.6 آ±â€‰5.1, 26.1 آ±â€‰7.5, and 42.9 آ±â€‰19.5 for volumetric changes of 1, 2, 3, and 4 mL) in a pattern similar to pressure (−6.8 آ±â€‰1.7, −6.8 آ±â€‰1.4, −9.4 آ±â€‰0.7, and −16.9 آ±â€‰6.8 cm H2O for 1, 2, 3, and 4 mL), reflecting changes in lung compliance. Measured rat lung tissue compliance was comparable to reported values from ex vivo lungs (0.178 آ±â€‰0.067, 0.378 آ±â€‰0.051, 0.427 آ±â€‰0.062, and 0.350 آ±â€‰0.160 mL/cm H20 for 1, 2, 3, and 4 mL), supporting proof of concept for the experimental method. Changes in echo intensity reflected changes in lung compliance in this ex vivo model, thus, supporting our hypothesis that the stiffnessrelated changes in echo intensity originally seen in tendon can be similarly detected in lung tissue. The presented ultrasoundbased methods allowed measurement of local lung tissue compliance in a controlled environment, however, the methods could be expanded to facilitate both ex vivo and in vivo studies.
    • Download: (361.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Ultrasound Assessment of Ex Vivo Lung Tissue Properties Using a Fluid Filled Negative Pressure Bath

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/154041
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorDuenwald
    contributor authorBates, Melissa L.
    contributor authorCortes, Sonia Y.
    contributor authorEldridge, Marlowe W.
    contributor authorVanderby, Ray
    date accessioned2017-05-09T01:05:32Z
    date available2017-05-09T01:05:32Z
    date issued2014
    identifier issn0148-0731
    identifier otherbio_136_07_074504.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/154041
    description abstractA relationship between tendon stress and strain and ultrasonic echo intensity has previously been defined in tendons, demonstrating a correlation between tissue stiffness and echo intensity. An analogous relationship between volumedependent pressure changes and echo intensity changes in inflating lungs would indicate a correlation between lung compliance and echo intensity. Lung compliance is an important metric to diagnose pathologies which affect lung tissue mechanics, such as emphysema and cystic fibrosis. The goal of this study is to demonstrate a correlation between ultrasound echo intensity and lung tissue mechanics in an ex vivo model using a fluidfilled negative pressure bath design which provides a controlled environment for ultrasonic and mechanical measurements. Lungs from 4 male SpragueDawley rats were removed and mechanically tested via inflation and deflation in a negative pressure chamber filled with hetastarch. Specific volumes (1, 2, 3, and 4 mL) were removed from the chamber using a syringe to create negative pressure, which resulted in lung inflation. A pressure transducer recorded the pressure around the lungs. From these data, lung compliance was calculated. Ultrasound images were captured through the chamber wall to determine echo intensity (grayscale brightness in the ultrasound image), which was then related to mechanical parameters. Ultrasound images of the lung were successfully captured through the chamber wall with sufficient resolution to deduce echo intensity changes in the lung tissue. Echo intensity (0–255 scale) increased with volumetric changes (18.4 آ±â€‰5.5, 22.6 آ±â€‰5.1, 26.1 آ±â€‰7.5, and 42.9 آ±â€‰19.5 for volumetric changes of 1, 2, 3, and 4 mL) in a pattern similar to pressure (−6.8 آ±â€‰1.7, −6.8 آ±â€‰1.4, −9.4 آ±â€‰0.7, and −16.9 آ±â€‰6.8 cm H2O for 1, 2, 3, and 4 mL), reflecting changes in lung compliance. Measured rat lung tissue compliance was comparable to reported values from ex vivo lungs (0.178 آ±â€‰0.067, 0.378 آ±â€‰0.051, 0.427 آ±â€‰0.062, and 0.350 آ±â€‰0.160 mL/cm H20 for 1, 2, 3, and 4 mL), supporting proof of concept for the experimental method. Changes in echo intensity reflected changes in lung compliance in this ex vivo model, thus, supporting our hypothesis that the stiffnessrelated changes in echo intensity originally seen in tendon can be similarly detected in lung tissue. The presented ultrasoundbased methods allowed measurement of local lung tissue compliance in a controlled environment, however, the methods could be expanded to facilitate both ex vivo and in vivo studies.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleUltrasound Assessment of Ex Vivo Lung Tissue Properties Using a Fluid Filled Negative Pressure Bath
    typeJournal Paper
    journal volume136
    journal issue7
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4027611
    journal fristpage74504
    journal lastpage74504
    identifier eissn1528-8951
    treeJournal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian