    Nucleus Implantation: The Biomechanics of Augmentation Versus Replacement With Varying Degrees of Nucleotomy

    Source: Journal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 005::page 51001
    Author:
    Cannella, Marco
    ,
    Isaacs, Jessica L.
    ,
    Allen, Shanee
    ,
    Orana, Argjenta
    ,
    Vresilovic, Edward
    ,
    Marcolongo, Michele
    DOI: 10.1115/1.4027056
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Nucleus pulposus replacement and augmentation has been proposed to restore disk mechanics in early stages of degeneration with the option of providing a minimally invasive procedure for pain relief to patients with an earlier stage of degeneration. The goal of this paper is to examine compressive stability of the intervertebral disk after either partial nucleus replacement or nuclear augmentation in the absence of denucleation. Thirteen human cadaver lumbar anterior column units were used to study the effects of denucleation and augmentation on the compressive mechanical behavior of the human intervertebral disk. Testing was performed in axial compression after incremental steps of partial denucleation and subsequent implantation of a synthetic hydrogel nucleus replacement. In a separate set of experiments, the disks were not denucleated but augmented with the same synthetic hydrogel nucleus replacement. Neutral zone, range of motion, and stiffness were measured. The results showed that compressive stabilization of the disk can be reestablished with nucleus replacement even for partial denucleation. Augmentation of the disk resulted in an increase in disk height and intradiskal pressure that were linearly related to the volume of polymer implanted. Intervertebral disk instability, evidenced by increased neutral zone and ranges of motion, associated with degeneration can be restored by volume filling of the nucleus pulposus using the hydrogel device presented here.
    • Download: (1.522Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Nucleus Implantation: The Biomechanics of Augmentation Versus Replacement With Varying Degrees of Nucleotomy

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/153997
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorCannella, Marco
    contributor authorIsaacs, Jessica L.
    contributor authorAllen, Shanee
    contributor authorOrana, Argjenta
    contributor authorVresilovic, Edward
    contributor authorMarcolongo, Michele
    date accessioned2017-05-09T01:05:24Z
    date available2017-05-09T01:05:24Z
    date issued2014
    identifier issn0148-0731
    identifier otherbio_136_05_051001.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/153997
    description abstractNucleus pulposus replacement and augmentation has been proposed to restore disk mechanics in early stages of degeneration with the option of providing a minimally invasive procedure for pain relief to patients with an earlier stage of degeneration. The goal of this paper is to examine compressive stability of the intervertebral disk after either partial nucleus replacement or nuclear augmentation in the absence of denucleation. Thirteen human cadaver lumbar anterior column units were used to study the effects of denucleation and augmentation on the compressive mechanical behavior of the human intervertebral disk. Testing was performed in axial compression after incremental steps of partial denucleation and subsequent implantation of a synthetic hydrogel nucleus replacement. In a separate set of experiments, the disks were not denucleated but augmented with the same synthetic hydrogel nucleus replacement. Neutral zone, range of motion, and stiffness were measured. The results showed that compressive stabilization of the disk can be reestablished with nucleus replacement even for partial denucleation. Augmentation of the disk resulted in an increase in disk height and intradiskal pressure that were linearly related to the volume of polymer implanted. Intervertebral disk instability, evidenced by increased neutral zone and ranges of motion, associated with degeneration can be restored by volume filling of the nucleus pulposus using the hydrogel device presented here.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleNucleus Implantation: The Biomechanics of Augmentation Versus Replacement With Varying Degrees of Nucleotomy
    typeJournal Paper
    journal volume136
    journal issue5
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4027056
    journal fristpage51001
    journal lastpage51001
    identifier eissn1528-8951
    treeJournal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian