    Cerebral Blood Flow in a Healthy Circle of Willis and Two Intracranial Aneurysms: Computational Fluid Dynamics Versus Four Dimensional Phase Contrast Magnetic Resonance Imaging

    Source: Journal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 004::page 41003
    Author:
    Berg, Philipp
    ,
    Stucht, Daniel
    ,
    Janiga, Gأ،bor
    ,
    Beuing, Oliver
    ,
    Speck, Oliver
    ,
    Thأ©venin, Dominique
    DOI: 10.1115/1.4026108
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Computational fluid dynamics (CFD) opens up multiple opportunities to investigate the hemodynamics of the human vascular system. However, due to numerous assumptions the acceptance of CFD among physicians is still limited in practice and validation through comparison is mandatory. Timedependent quantitative phasecontrast magnetic resonance imaging PCMRI measurements in a healthy volunteer and two intracranial aneurysms were carried out at 3 and 7 Tesla. Based on the acquired images, threedimensional (3D) models of the aneurysms were reconstructed and used for the numerical simulations. Flow information from the MR measurements were applied as boundary conditions. The fourdimensional (4D) velocity fields obtained by CFD and MRI were qualitatively as well as quantitatively compared including cut planes and vector analyses. For all cases a high similarity of the velocity patterns was observed. Additionally, the quantitative analysis revealed a good agreement between CFD and MRI. Deviations were caused by minor differences between the reconstructed vessel models and the actual lumen. The comparisons between diastole and systole indicate that relative differences between MRI and CFD are intensified with increasing velocity. The findings of this study lead to the conclusion that CFD and MRI agree well in predicting intracranial velocities when realistic geometries and boundary conditions are provided. Due to the considerably higher temporal and spatial resolution of CFD compared to MRI, complex flow patterns can be further investigated in order to evaluate their role with respect to aneurysm formation or rupture. Nevertheless, special care is required regarding the vessel reconstruction since the geometry has a major impact on the subsequent numerical results.
    • Download: (3.342Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Cerebral Blood Flow in a Healthy Circle of Willis and Two Intracranial Aneurysms: Computational Fluid Dynamics Versus Four Dimensional Phase Contrast Magnetic Resonance Imaging

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/153988
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorBerg, Philipp
    contributor authorStucht, Daniel
    contributor authorJaniga, Gأ،bor
    contributor authorBeuing, Oliver
    contributor authorSpeck, Oliver
    contributor authorThأ©venin, Dominique
    date accessioned2017-05-09T01:05:22Z
    date available2017-05-09T01:05:22Z
    date issued2014
    identifier issn0148-0731
    identifier otherbio_136_04_041003.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/153988
    description abstractComputational fluid dynamics (CFD) opens up multiple opportunities to investigate the hemodynamics of the human vascular system. However, due to numerous assumptions the acceptance of CFD among physicians is still limited in practice and validation through comparison is mandatory. Timedependent quantitative phasecontrast magnetic resonance imaging PCMRI measurements in a healthy volunteer and two intracranial aneurysms were carried out at 3 and 7 Tesla. Based on the acquired images, threedimensional (3D) models of the aneurysms were reconstructed and used for the numerical simulations. Flow information from the MR measurements were applied as boundary conditions. The fourdimensional (4D) velocity fields obtained by CFD and MRI were qualitatively as well as quantitatively compared including cut planes and vector analyses. For all cases a high similarity of the velocity patterns was observed. Additionally, the quantitative analysis revealed a good agreement between CFD and MRI. Deviations were caused by minor differences between the reconstructed vessel models and the actual lumen. The comparisons between diastole and systole indicate that relative differences between MRI and CFD are intensified with increasing velocity. The findings of this study lead to the conclusion that CFD and MRI agree well in predicting intracranial velocities when realistic geometries and boundary conditions are provided. Due to the considerably higher temporal and spatial resolution of CFD compared to MRI, complex flow patterns can be further investigated in order to evaluate their role with respect to aneurysm formation or rupture. Nevertheless, special care is required regarding the vessel reconstruction since the geometry has a major impact on the subsequent numerical results.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleCerebral Blood Flow in a Healthy Circle of Willis and Two Intracranial Aneurysms: Computational Fluid Dynamics Versus Four Dimensional Phase Contrast Magnetic Resonance Imaging
    typeJournal Paper
    journal volume136
    journal issue4
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4026108
    journal fristpage41003
    journal lastpage41003
    identifier eissn1528-8951
    treeJournal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 004
    contenttypeFulltext