    Diagnostic Uncertainties During Assessment of Serial Coronary Stenoses: An In Vitro Study

    Source: Journal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 002::page 21026
    Author:
    D’Souza, Gavin A.
    ,
    Peelukhana, Srikara V.
    ,
    Banerjee, Rupak K.
    DOI: 10.1115/1.4026317
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Currently, the diagnosis of coronary stenosis is primarily based on the wellestablished functional diagnostic parameter, fractional flow reserve (FFR: ratio of pressures distal and proximal to a stenosis). The threshold of FFR has a “grayâ€‌ zone of 0.75–0.80, below which further clinical intervention is recommended. An alternate diagnostic parameter, pressure drop coefficient (CDP: ratio of transstenotic pressure drop to the proximal dynamic pressure), developed based on fundamental fluid dynamics principles, has been suggested by our group. Additional serial stenosis, present downstream in a single vessel, reduces the hyperemic flow, Qثœh, and pressure drop, خ”pثœ, across an upstream stenosis. Such hemodynamic variations may alter the values of FFR and CDP of the upstream stenosis. Thus, in the presence of serial stenoses, there is a need to evaluate the possibility of misinterpretation of FFR and test the efficacy of CDP of individual stenoses. Invitro experiments simulating physiologic conditions, along with human data, were used to evaluate nine combinations of serial stenoses. Different cases of upstream stenosis (mild: 64% area stenosis (AS) or 40% diameter stenosis (DS); intermediate: 80% AS or 55% DS; and severe: 90% AS or 68% DS) were tested under varying degrees of downstream stenosis (mild, intermediate, and severe). The pressure dropflow rate characteristics of the serial stenoses combinations were evaluated for determining the effect of the downstream stenosis on the upstream stenosis. In general, Qثœh and خ”pثœ across the upstream stenosis decreased when the downstream stenosis severity was increased. The FFR of the upstream mild, intermediate, and severe stenosis increased by a maximum of 3%, 13%, and 19%, respectively, when the downstream stenosis severity increased from mild to severe. The FFR of a standalone intermediate stenosis under a clinical setting is reported to be ∼0.72. In the presence of a downstream stenosis, the FFR values of the upstream intermediate stenosis were either within (0.77 for 80%–64% AS and 0.79 for 80%–80% AS) or above (0.88 for 80%–90% AS) the “grayâ€‌ zone (0.75–0.80). This artificial increase in the FFR value within or above the “grayâ€‌ zone for an upstream intermediate stenosis when in series with a clinically relevant downstream stenosis could lead to misinterpretation of functional stenosis severity. In contrast, a distinct range of CDP values was observed for each case of upstream stenosis (mild: 8–10; intermediate: 47–54; and severe: 130–155). The nonoverlapping range of CDP could better delineate the effect of the downstream stenosis from the upstream stenosis and allow for the accurate diagnosis of the functional severity of the upstream stenosis.
    • Download: (1.750Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Diagnostic Uncertainties During Assessment of Serial Coronary Stenoses: An In Vitro Study

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/153966
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorD’Souza, Gavin A.
    contributor authorPeelukhana, Srikara V.
    contributor authorBanerjee, Rupak K.
    date accessioned2017-05-09T01:05:18Z
    date available2017-05-09T01:05:18Z
    date issued2014
    identifier issn0148-0731
    identifier otherbio_136_02_021026.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/153966
    description abstractCurrently, the diagnosis of coronary stenosis is primarily based on the wellestablished functional diagnostic parameter, fractional flow reserve (FFR: ratio of pressures distal and proximal to a stenosis). The threshold of FFR has a “grayâ€‌ zone of 0.75–0.80, below which further clinical intervention is recommended. An alternate diagnostic parameter, pressure drop coefficient (CDP: ratio of transstenotic pressure drop to the proximal dynamic pressure), developed based on fundamental fluid dynamics principles, has been suggested by our group. Additional serial stenosis, present downstream in a single vessel, reduces the hyperemic flow, Qثœh, and pressure drop, خ”pثœ, across an upstream stenosis. Such hemodynamic variations may alter the values of FFR and CDP of the upstream stenosis. Thus, in the presence of serial stenoses, there is a need to evaluate the possibility of misinterpretation of FFR and test the efficacy of CDP of individual stenoses. Invitro experiments simulating physiologic conditions, along with human data, were used to evaluate nine combinations of serial stenoses. Different cases of upstream stenosis (mild: 64% area stenosis (AS) or 40% diameter stenosis (DS); intermediate: 80% AS or 55% DS; and severe: 90% AS or 68% DS) were tested under varying degrees of downstream stenosis (mild, intermediate, and severe). The pressure dropflow rate characteristics of the serial stenoses combinations were evaluated for determining the effect of the downstream stenosis on the upstream stenosis. In general, Qثœh and خ”pثœ across the upstream stenosis decreased when the downstream stenosis severity was increased. The FFR of the upstream mild, intermediate, and severe stenosis increased by a maximum of 3%, 13%, and 19%, respectively, when the downstream stenosis severity increased from mild to severe. The FFR of a standalone intermediate stenosis under a clinical setting is reported to be ∼0.72. In the presence of a downstream stenosis, the FFR values of the upstream intermediate stenosis were either within (0.77 for 80%–64% AS and 0.79 for 80%–80% AS) or above (0.88 for 80%–90% AS) the “grayâ€‌ zone (0.75–0.80). This artificial increase in the FFR value within or above the “grayâ€‌ zone for an upstream intermediate stenosis when in series with a clinically relevant downstream stenosis could lead to misinterpretation of functional stenosis severity. In contrast, a distinct range of CDP values was observed for each case of upstream stenosis (mild: 8–10; intermediate: 47–54; and severe: 130–155). The nonoverlapping range of CDP could better delineate the effect of the downstream stenosis from the upstream stenosis and allow for the accurate diagnosis of the functional severity of the upstream stenosis.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDiagnostic Uncertainties During Assessment of Serial Coronary Stenoses: An In Vitro Study
    typeJournal Paper
    journal volume136
    journal issue2
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4026317
    journal fristpage21026
    journal lastpage21026
    identifier eissn1528-8951
    treeJournal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian