    Heat Transfer and Pressure Drop Measurements in High Solidity Pin Fin Cooling Arrays With Incremental Replenishment

    Source: Journal of Turbomachinery:;2013:;volume( 135 ):;issue: 004::page 41011
    Author:
    Busche, Mitch L.
    ,
    Moualeu, Leolein P.
    ,
    Chowdhury, Nafiz
    ,
    Tang, Clement
    ,
    Ames, Forrest E.
    DOI: 10.1115/1.4007581
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Leading edge heat loads on turbine airfoils can be reduced by increasing the diameter of the leading edge. The lower external heat transfer and more generous curvature may allow for cooling this region internally. Large diameter leading edge regions are expected to exhibit a relatively broad region with nearly constant heat transfer. However, the ability of internal passages to cool a surface diminishes with distance as cooling air picks up thermal energy within the passage. Two novel internal cooling geometries have been designed and tested, which incrementally replenish cooling air by using impingement holes distributed along the array. These cooling methods have been compared to a baseline high solidity passage in terms of both array heat transfer and pressure drop. Heat transfer rates and pressure drop have been determined on a row by row basis to provide a means to assess their ability to sustain adequate cooling levels across the entire leading edge region. The authors believe turbine airfoil designs integrating large diameter leading edge regions with properly designed internal passages have the potential to eliminate showerhead cooling arrays in many industrial gas turbine applications. This change is especially beneficial in environments where fuel or air impurities have the potential to clog leading edge showerhead cooling arrays. Heat transfer and pressure drop measurements were acquired in a bench scale test rig. Reynolds numbers ranged from approximately 5000 to 60,000 for the constant height channel arrays based on the pin diameter and the local maximum average velocity across a row. The high solidity pin fin arrays have an axial spacing (X/D) of 1.074 and a cross channel spacing (S/D) of 1.625. The constant section pin fin arrays have channel height to diameter ratios of 0.5. Each array has eight rows of pins with six pins per row in a staggered arrangement. Heat transfer testing was conducted using a constant temperature boundary condition.
    • Download: (2.165Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Heat Transfer and Pressure Drop Measurements in High Solidity Pin Fin Cooling Arrays With Incremental Replenishment

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/153465
    Collections
    • Journal of Turbomachinery

    Show full item record

    contributor authorBusche, Mitch L.
    contributor authorMoualeu, Leolein P.
    contributor authorChowdhury, Nafiz
    contributor authorTang, Clement
    contributor authorAmes, Forrest E.
    date accessioned2017-05-09T01:03:41Z
    date available2017-05-09T01:03:41Z
    date issued2013
    identifier issn0889-504X
    identifier otherturb_135_4_041011.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/153465
    description abstractLeading edge heat loads on turbine airfoils can be reduced by increasing the diameter of the leading edge. The lower external heat transfer and more generous curvature may allow for cooling this region internally. Large diameter leading edge regions are expected to exhibit a relatively broad region with nearly constant heat transfer. However, the ability of internal passages to cool a surface diminishes with distance as cooling air picks up thermal energy within the passage. Two novel internal cooling geometries have been designed and tested, which incrementally replenish cooling air by using impingement holes distributed along the array. These cooling methods have been compared to a baseline high solidity passage in terms of both array heat transfer and pressure drop. Heat transfer rates and pressure drop have been determined on a row by row basis to provide a means to assess their ability to sustain adequate cooling levels across the entire leading edge region. The authors believe turbine airfoil designs integrating large diameter leading edge regions with properly designed internal passages have the potential to eliminate showerhead cooling arrays in many industrial gas turbine applications. This change is especially beneficial in environments where fuel or air impurities have the potential to clog leading edge showerhead cooling arrays. Heat transfer and pressure drop measurements were acquired in a bench scale test rig. Reynolds numbers ranged from approximately 5000 to 60,000 for the constant height channel arrays based on the pin diameter and the local maximum average velocity across a row. The high solidity pin fin arrays have an axial spacing (X/D) of 1.074 and a cross channel spacing (S/D) of 1.625. The constant section pin fin arrays have channel height to diameter ratios of 0.5. Each array has eight rows of pins with six pins per row in a staggered arrangement. Heat transfer testing was conducted using a constant temperature boundary condition.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleHeat Transfer and Pressure Drop Measurements in High Solidity Pin Fin Cooling Arrays With Incremental Replenishment
    typeJournal Paper
    journal volume135
    journal issue4
    journal titleJournal of Turbomachinery
    identifier doi10.1115/1.4007581
    journal fristpage41011
    journal lastpage41011
    identifier eissn1528-8900
    treeJournal of Turbomachinery:;2013:;volume( 135 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian