YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Novel Method to Evaluate Angular Stiffness of Prosthetic Feet From Linear Compression Tests

    Source: Journal of Biomechanical Engineering:;2013:;volume( 135 ):;issue: 010::page 104502
    Author:
    Adamczyk, Peter G
    ,
    Roland, Michelle
    ,
    Hahn, Michael E.
    DOI: 10.1115/1.4025104
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Lower limb amputee gait during stance phase is related to the angular stiffness of the prosthetic foot, which describes the dependence of ankle torque on angular progression of the shank. However, there is little data on angular stiffness of prosthetic feet, and no method to directly measure it has been described. The objective of this study was to derive and evaluate a method to estimate the angular stiffness of prosthetic feet using a simple linear compression test. Linear vertical compression tests were performed on nine configurations of an experimental multicomponent foot (with known component stiffness properties and geometry), which allowed for parametric adjustment of hindfoot and forefoot stiffness properties and geometries. Each configuration was loaded under displacement control at distinct pylon test angles. Angular stiffness was calculated as a function of the pylon angle, normal force, and center of pressure (COP) rate of change with respect to linear displacement. Population root mean square error (RMSE) between the measured and predicted angular stiffness values for each configuration of the multicomponent foot was calculated to be 4.1 Nm/deg, dominated by a bias of the estimated values above the predicted values of 3.8 آ±â€‰1.6 Nm/deg. The bestfit line to estimated values was approximately parallel to the prediction, with R2 = 0.95. This method should be accessible for a variety of laboratories to estimate angular stiffness of experimental and commercially available prosthetic feet with minimal equipment.
    • Download: (516.5Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Novel Method to Evaluate Angular Stiffness of Prosthetic Feet From Linear Compression Tests

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/151110
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorAdamczyk, Peter G
    contributor authorRoland, Michelle
    contributor authorHahn, Michael E.
    date accessioned2017-05-09T00:56:50Z
    date available2017-05-09T00:56:50Z
    date issued2013
    identifier issn0148-0731
    identifier otherbio_135_10_104502.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/151110
    description abstractLower limb amputee gait during stance phase is related to the angular stiffness of the prosthetic foot, which describes the dependence of ankle torque on angular progression of the shank. However, there is little data on angular stiffness of prosthetic feet, and no method to directly measure it has been described. The objective of this study was to derive and evaluate a method to estimate the angular stiffness of prosthetic feet using a simple linear compression test. Linear vertical compression tests were performed on nine configurations of an experimental multicomponent foot (with known component stiffness properties and geometry), which allowed for parametric adjustment of hindfoot and forefoot stiffness properties and geometries. Each configuration was loaded under displacement control at distinct pylon test angles. Angular stiffness was calculated as a function of the pylon angle, normal force, and center of pressure (COP) rate of change with respect to linear displacement. Population root mean square error (RMSE) between the measured and predicted angular stiffness values for each configuration of the multicomponent foot was calculated to be 4.1 Nm/deg, dominated by a bias of the estimated values above the predicted values of 3.8 آ±â€‰1.6 Nm/deg. The bestfit line to estimated values was approximately parallel to the prediction, with R2 = 0.95. This method should be accessible for a variety of laboratories to estimate angular stiffness of experimental and commercially available prosthetic feet with minimal equipment.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleNovel Method to Evaluate Angular Stiffness of Prosthetic Feet From Linear Compression Tests
    typeJournal Paper
    journal volume135
    journal issue10
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4025104
    journal fristpage104502
    journal lastpage104502
    identifier eissn1528-8951
    treeJournal of Biomechanical Engineering:;2013:;volume( 135 ):;issue: 010
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian