YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    The Effect of the Variation in ACL Constitutive Model on Joint Kinematics and Biomechanics Under Different Loads: A Finite Element Study

    Source: Journal of Biomechanical Engineering:;2013:;volume( 135 ):;issue: 004::page 41002
    Author:
    Wan, Chao
    ,
    Hao, Zhixiu
    ,
    Wen, Shizhu
    DOI: 10.1115/1.4023696
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The biomechanics and function of the anterior cruciate ligament (ACL) have been widely studied using both experimental and simulation methods. It is known that a constitutive model of joint tissue is a critical factor in the numerical simulation. Some different ligament constitutive models have been presented to describe the ACL material behavior. However, the effect of the variation in the ligament constitutive model on joint kinematics and biomechanics has still not been studied. In this paper, a threedimensional finite element model of an intact tibiofemoral joint was reconstructed. Three ACL constitutive models were compared under different joint loads (such as anterior tibial force, varus tibial torque, and valgus tibial torque) to investigate the effect of the change of the ACL constitutive model. The three constitutive models corresponded to an isotropic hyperelasticity model, a transversely isotropic hyperelasticity model with neoHookean ground substance description, and a transversely isotropic hyperelastic model with nonlinear ground substance description. Although the material properties of these constitutive equations were fitted on the same uniaxial tension stressstrain curve, the change of the ACL material constitutive model was found to induce altered joint kinematics and biomechanics. The effect of different ACL constitutive equations on joint kinematics depended on both deformation direction and load type. The variation in the ACL constitutive models would influence the joint kinematic results greatly in both the anterior and internal directions under anterior tibial force as well as some other deformations such as the anterior and medial tibial translations under valgus tibial torque, and the medial tibial translation and internal rotation under varus torque. It was revealed that the transversely isotropic hyperelastic model with nonlinear ground substance description (FE model III) was the best representation of the realistic ACL property by a linear regression between the simulated and the experiment deformation results. But the comparison of the predicted and experiment force of ligaments showed that all the three ACL constitutive models represented similar force results. The stress value and distribution of ACL were also altered by the change in the constitutive equation. In brief, although different ACL constitutive models have been fitted using the same uniaxial tension curve and have the similar longitudinal material property, the ACL constitutive equation should still be carefully chosen to investigate joint kinematics and biomechanics due to the different transverse material behavior.
    • Download: (2.055Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      The Effect of the Variation in ACL Constitutive Model on Joint Kinematics and Biomechanics Under Different Loads: A Finite Element Study

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/151017
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorWan, Chao
    contributor authorHao, Zhixiu
    contributor authorWen, Shizhu
    date accessioned2017-05-09T00:56:35Z
    date available2017-05-09T00:56:35Z
    date issued2013
    identifier issn0148-0731
    identifier otherbio_135_4_041002.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/151017
    description abstractThe biomechanics and function of the anterior cruciate ligament (ACL) have been widely studied using both experimental and simulation methods. It is known that a constitutive model of joint tissue is a critical factor in the numerical simulation. Some different ligament constitutive models have been presented to describe the ACL material behavior. However, the effect of the variation in the ligament constitutive model on joint kinematics and biomechanics has still not been studied. In this paper, a threedimensional finite element model of an intact tibiofemoral joint was reconstructed. Three ACL constitutive models were compared under different joint loads (such as anterior tibial force, varus tibial torque, and valgus tibial torque) to investigate the effect of the change of the ACL constitutive model. The three constitutive models corresponded to an isotropic hyperelasticity model, a transversely isotropic hyperelasticity model with neoHookean ground substance description, and a transversely isotropic hyperelastic model with nonlinear ground substance description. Although the material properties of these constitutive equations were fitted on the same uniaxial tension stressstrain curve, the change of the ACL material constitutive model was found to induce altered joint kinematics and biomechanics. The effect of different ACL constitutive equations on joint kinematics depended on both deformation direction and load type. The variation in the ACL constitutive models would influence the joint kinematic results greatly in both the anterior and internal directions under anterior tibial force as well as some other deformations such as the anterior and medial tibial translations under valgus tibial torque, and the medial tibial translation and internal rotation under varus torque. It was revealed that the transversely isotropic hyperelastic model with nonlinear ground substance description (FE model III) was the best representation of the realistic ACL property by a linear regression between the simulated and the experiment deformation results. But the comparison of the predicted and experiment force of ligaments showed that all the three ACL constitutive models represented similar force results. The stress value and distribution of ACL were also altered by the change in the constitutive equation. In brief, although different ACL constitutive models have been fitted using the same uniaxial tension curve and have the similar longitudinal material property, the ACL constitutive equation should still be carefully chosen to investigate joint kinematics and biomechanics due to the different transverse material behavior.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleThe Effect of the Variation in ACL Constitutive Model on Joint Kinematics and Biomechanics Under Different Loads: A Finite Element Study
    typeJournal Paper
    journal volume135
    journal issue4
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4023696
    journal fristpage41002
    journal lastpage41002
    identifier eissn1528-8951
    treeJournal of Biomechanical Engineering:;2013:;volume( 135 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian