    Transient Calorimetric Measurement Method for Total Hemispherical Emissivity

    Source: Journal of Heat Transfer:;2012:;volume( 134 ):;issue: 011::page 111601
    Author:
    Tairan Fu
    ,
    Peng Tan
    DOI: 10.1115/1.4006896
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The transient calorimetric technique was used to measure the total hemispherical emissivity of conductive materials. The emissivity was measured in a small central region of a thin strip heated electrically in a vacuum chamber. The axial heat transfer along the sample and the heat losses from the wires were considered in the transient heat transfer calculations. An appropriate time interval for the hot sample cooling rate is needed to improve the emissivity solution accuracy. Two ways were used to analyze the data, based on the known specific heat and the assumed functions of the emissivity and the specific heat. Comparisons with steady-state data showed that their results are very similar with a maximum difference of only 13% (944 K). Therefore, the transient method based on the function assumption is a good choice for measurements when there are inaccurate or insufficient specific heat data at the desired temperatures. Since ferromagnetic materials have Curie points at higher temperatures, this study also investigated the applicability of the transient calorimetric technique for high temperature emissivity measurements. For higher temperatures above the Curie point, the steady-state method is more accurate than the transient method. These analyses provide a comprehensive understanding of the transient method for measuring the total hemispherical emissivity.
    keyword(s): Specific heat , Temperature , Cooling , Emissivity , Functions AND Steady state ,
    • Download: (768.1Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Transient Calorimetric Measurement Method for Total Hemispherical Emissivity

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/149315
    Collections
    • Journal of Heat Transfer

    Show full item record

    contributor authorTairan Fu
    contributor authorPeng Tan
    date accessioned2017-05-09T00:51:54Z
    date available2017-05-09T00:51:54Z
    date copyrightNovember, 2012
    date issued2012
    identifier issn0022-1481
    identifier otherJHTRAO-926057#111601_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/149315
    description abstractThe transient calorimetric technique was used to measure the total hemispherical emissivity of conductive materials. The emissivity was measured in a small central region of a thin strip heated electrically in a vacuum chamber. The axial heat transfer along the sample and the heat losses from the wires were considered in the transient heat transfer calculations. An appropriate time interval for the hot sample cooling rate is needed to improve the emissivity solution accuracy. Two ways were used to analyze the data, based on the known specific heat and the assumed functions of the emissivity and the specific heat. Comparisons with steady-state data showed that their results are very similar with a maximum difference of only 13% (944 K). Therefore, the transient method based on the function assumption is a good choice for measurements when there are inaccurate or insufficient specific heat data at the desired temperatures. Since ferromagnetic materials have Curie points at higher temperatures, this study also investigated the applicability of the transient calorimetric technique for high temperature emissivity measurements. For higher temperatures above the Curie point, the steady-state method is more accurate than the transient method. These analyses provide a comprehensive understanding of the transient method for measuring the total hemispherical emissivity.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleTransient Calorimetric Measurement Method for Total Hemispherical Emissivity
    typeJournal Paper
    journal volume134
    journal issue11
    journal titleJournal of Heat Transfer
    identifier doi10.1115/1.4006896
    journal fristpage111601
    identifier eissn1528-8943
    keywordsSpecific heat
    keywordsTemperature
    keywordsCooling
    keywordsEmissivity
    keywordsFunctions AND Steady state
    treeJournal of Heat Transfer:;2012:;volume( 134 ):;issue: 011
    contenttypeFulltext