YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Comparison of the In Vitro Hemodynamic Performance of New Flow Diverters for Bypass of Brain Aneurysms

    Source: Journal of Biomechanical Engineering:;2012:;volume( 134 ):;issue: 008::page 84505
    Author:
    Asher L. Trager
    ,
    Chander Sadasivan
    ,
    Baruch B. Lieber
    DOI: 10.1115/1.4006454
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: One possible treatment for cerebral aneurysms is a porous tubular structure, similar to a stent, called a flow diverter. A flow diverter can be placed across the neck of a cerebral aneurysm to induce the cessation of flow and initiate the formation of an intra-aneurysmal thrombus. This excludes the aneurysm from the parent artery and returns the flow of blood to normal. Previous flow diverting devices have been analyzed to determine optimal characteristics, such as braiding angle and wire diameter. From this information, a new optimized device was designed to achieve equivalent hemodynamic performance to the previous best device, but with better longitudinal flexibility to preserve physiological arterial configuration. The new device was tested in vitro in an elastomeric replica of the rabbit elastase induced aneurysm model and is now in the process of being tested in vivo. Particle image velocimetry was utilized to determine the velocity field in the plane of symmetry of the model under pulsatile flow conditions. Device hemodynamic performance indices such as the hydrodynamic circulation were evaluated from the velocity fields. Comparison of these indices with the previous best device and a control shows that the significant design changes of the device did not change its hemodynamic attributes (p > 0.05).
    keyword(s): Flow (Dynamics) , Hemodynamics , Aneurysms AND Brain ,
    • Download: (1.255Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Comparison of the In Vitro Hemodynamic Performance of New Flow Diverters for Bypass of Brain Aneurysms

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/148229
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorAsher L. Trager
    contributor authorChander Sadasivan
    contributor authorBaruch B. Lieber
    date accessioned2017-05-09T00:48:26Z
    date available2017-05-09T00:48:26Z
    date copyrightAugust, 2012
    date issued2012
    identifier issn0148-0731
    identifier otherJBENDY-29000#084505_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/148229
    description abstractOne possible treatment for cerebral aneurysms is a porous tubular structure, similar to a stent, called a flow diverter. A flow diverter can be placed across the neck of a cerebral aneurysm to induce the cessation of flow and initiate the formation of an intra-aneurysmal thrombus. This excludes the aneurysm from the parent artery and returns the flow of blood to normal. Previous flow diverting devices have been analyzed to determine optimal characteristics, such as braiding angle and wire diameter. From this information, a new optimized device was designed to achieve equivalent hemodynamic performance to the previous best device, but with better longitudinal flexibility to preserve physiological arterial configuration. The new device was tested in vitro in an elastomeric replica of the rabbit elastase induced aneurysm model and is now in the process of being tested in vivo. Particle image velocimetry was utilized to determine the velocity field in the plane of symmetry of the model under pulsatile flow conditions. Device hemodynamic performance indices such as the hydrodynamic circulation were evaluated from the velocity fields. Comparison of these indices with the previous best device and a control shows that the significant design changes of the device did not change its hemodynamic attributes (p > 0.05).
    publisherThe American Society of Mechanical Engineers (ASME)
    titleComparison of the In Vitro Hemodynamic Performance of New Flow Diverters for Bypass of Brain Aneurysms
    typeJournal Paper
    journal volume134
    journal issue8
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4006454
    journal fristpage84505
    identifier eissn1528-8951
    keywordsFlow (Dynamics)
    keywordsHemodynamics
    keywordsAneurysms AND Brain
    treeJournal of Biomechanical Engineering:;2012:;volume( 134 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian