    3D Graphical Rendering of Localized Lumps and Arteries for Robotic Assisted MIS

    Source: Journal of Medical Devices:;2011:;volume( 005 ):;issue: 002::page 21002
    Author:
    Masoud Kalantari
    ,
    Mohammadreza Ramezanifard
    ,
    Jozsef Kövecses
    ,
    Javad Dargahi
    DOI: 10.1115/1.4003736
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Detection of hard inclusions within soft tissue in robotic assisted minimally invasive surgery (MIS), also referred to as laparoscopic surgery, is of great importance, both in clinical and surgical applications. In clinical applications, surgeons need to detect and precisely identify the location and size of all growths, whether cancerous or benign, that are present within surrounding tissue in order to assess the extent and nature of any future treatment plan. In surgical applications, when any solid matter is being removed, it is important to avoid accidental injury to surrounding tissues and blood vessels since, were this to occur, it could then necessitate the need to resort to open surgery. The present study is aimed at developing a three-dimensional tactile display that provides palpation capability to any surgeon performing robotic assisted MIS. The information is collected from two force sensor/pressure matrices and processed with a new algorithm and graphically rendered. Consequently, the surgeon can determine the presence, location, and the size of any hidden superficial tumor/artery by grasping the target tissue in a quasi-dynamic way. The developed algorithm is presented, and the results for various configurations of embedded tumor/arteries inside the tissue are compared with those of the finite element analysis.
    keyword(s): Sensors , Dimensions , Algorithms , Surgery , Force sensors , Pressure , Rendering AND Modeling ,
    • Download: (1.015Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      3D Graphical Rendering of Localized Lumps and Arteries for Robotic Assisted MIS

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/147264
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorMasoud Kalantari
    contributor authorMohammadreza Ramezanifard
    contributor authorJozsef Kövecses
    contributor authorJavad Dargahi
    date accessioned2017-05-09T00:46:13Z
    date available2017-05-09T00:46:13Z
    date copyrightJune, 2011
    date issued2011
    identifier issn1932-6181
    identifier otherJMDOA4-28018#021002_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/147264
    description abstractDetection of hard inclusions within soft tissue in robotic assisted minimally invasive surgery (MIS), also referred to as laparoscopic surgery, is of great importance, both in clinical and surgical applications. In clinical applications, surgeons need to detect and precisely identify the location and size of all growths, whether cancerous or benign, that are present within surrounding tissue in order to assess the extent and nature of any future treatment plan. In surgical applications, when any solid matter is being removed, it is important to avoid accidental injury to surrounding tissues and blood vessels since, were this to occur, it could then necessitate the need to resort to open surgery. The present study is aimed at developing a three-dimensional tactile display that provides palpation capability to any surgeon performing robotic assisted MIS. The information is collected from two force sensor/pressure matrices and processed with a new algorithm and graphically rendered. Consequently, the surgeon can determine the presence, location, and the size of any hidden superficial tumor/artery by grasping the target tissue in a quasi-dynamic way. The developed algorithm is presented, and the results for various configurations of embedded tumor/arteries inside the tissue are compared with those of the finite element analysis.
    publisherThe American Society of Mechanical Engineers (ASME)
    title3D Graphical Rendering of Localized Lumps and Arteries for Robotic Assisted MIS
    typeJournal Paper
    journal volume5
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4003736
    journal fristpage21002
    identifier eissn1932-619X
    keywordsSensors
    keywordsDimensions
    keywordsAlgorithms
    keywordsSurgery
    keywordsForce sensors
    keywordsPressure
    keywordsRendering AND Modeling
    treeJournal of Medical Devices:;2011:;volume( 005 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian