    Archive

    Patterning PLA Packaging Films for Implantable Medical Devices

    Source: Journal of Medical Devices:;2011:;volume( 005 ):;issue: 002::page 27522
    Author:
    Radheshyam Tewari
    ,
    Craig Friedrich
    DOI: 10.1115/1.3590627
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Microhot-embossing is a less complex and inexpensive alternative over standard photolithography for patterning poly(lactic acid) (PLA) films. However, direct patterning of discrete or through-thickness microstructures by conventional microhot-embossing is not possible due to embossing-caused residual film. Use of complex modifications in the embossing process can further prohibit its integration with other standard semiconductor fabrication processes. Plasma-based reactive ion etching (RIE) of embossing-caused PLA residual film can be a viable option potentially allowing integration of the conventional hot-embossing process with standard semiconductor fabrication processes. RIE etch-rates of PLA packaging films, hot-embossed with parylene-based thin-film cochlear implant-shaped stiffener structures, were characterized for oxygen (O2), nitrogen (N2), and argon (Ar) plasmas under two different process conditions. The etch-rates of PLA films for O2, N2, and Ar plasmas were 0.29–0.72 μm/min, 0.09–0.14 μm/min, and 0.11–0.15 μm/min, respectively. Complete removal of embossing-caused residual film has been demonstrated utilizing the etching results for O2 plasma. Also, the effect of RIE etching on resultant PLA film surface roughness has been quantified for the three plasmas.
    keyword(s): Medical devices ,
    • Download: (34.75Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Patterning PLA Packaging Films for Implantable Medical Devices

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/147240
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorRadheshyam Tewari
    contributor authorCraig Friedrich
    date accessioned2017-05-09T00:46:12Z
    date available2017-05-09T00:46:12Z
    date copyrightJune, 2011
    date issued2011
    identifier issn1932-6181
    identifier otherJMDOA4-28018#027522_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/147240
    description abstractMicrohot-embossing is a less complex and inexpensive alternative over standard photolithography for patterning poly(lactic acid) (PLA) films. However, direct patterning of discrete or through-thickness microstructures by conventional microhot-embossing is not possible due to embossing-caused residual film. Use of complex modifications in the embossing process can further prohibit its integration with other standard semiconductor fabrication processes. Plasma-based reactive ion etching (RIE) of embossing-caused PLA residual film can be a viable option potentially allowing integration of the conventional hot-embossing process with standard semiconductor fabrication processes. RIE etch-rates of PLA packaging films, hot-embossed with parylene-based thin-film cochlear implant-shaped stiffener structures, were characterized for oxygen (O2), nitrogen (N2), and argon (Ar) plasmas under two different process conditions. The etch-rates of PLA films for O2, N2, and Ar plasmas were 0.29–0.72 μm/min, 0.09–0.14 μm/min, and 0.11–0.15 μm/min, respectively. Complete removal of embossing-caused residual film has been demonstrated utilizing the etching results for O2 plasma. Also, the effect of RIE etching on resultant PLA film surface roughness has been quantified for the three plasmas.
    publisherThe American Society of Mechanical Engineers (ASME)
    titlePatterning PLA Packaging Films for Implantable Medical Devices
    typeJournal Paper
    journal volume5
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.3590627
    journal fristpage27522
    identifier eissn1932-619X
    keywordsMedical devices
    treeJournal of Medical Devices:;2011:;volume( 005 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian