YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Heat Transfer
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Heat Transfer
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Determination of the Number of Tube Rows to Obtain Closure for Volume Averaging Theory Based Model of Fin-and-Tube Heat Exchangers

    Source: Journal of Heat Transfer:;2011:;volume( 133 ):;issue: 012::page 121801
    Author:
    Feng Zhou
    ,
    Nicholas E. Hansen
    ,
    David J. Geb
    ,
    Ivan Catton
    DOI: 10.1115/1.4004478
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Modeling of fin-and-tube heat exchangers based on the volume averaging theory (VAT) requires proper closure of the VAT based governing equations. Closure can be obtained from reasonable lower scale solutions of a computational fluid dynamics (CFD) code, which means the tube row number chosen should be large enough, so that the closure can be evaluated for a representative elementary volume (REV) that is, not affected by the entrance or recirculation at the outlet of the fin gap. To determine the number of tube rows, three-dimensional numerical simulations for plate fin-and-tube heat exchangers were performed, with the Reynolds number varying from 500 to 6000 and the number of tube rows varying from 1 to 9. A clear perspective of the variations of both overall and local fiction factor and the Nusselt number as the tube row number increases are presented. These variation trends are explained from the view point of the field synergy principle (FSP). Our investigation shows that 4 + 1 + 1 tube rows is the minimum number to get reasonable lower scale solutions. A computational domain including 5 + 2 + 2 tube rows is recommended, so that the closure formulas for drag resistance coefficient and heat transfer coefficient could be evaluated for the sixth and seventh elementary volumes to close the VAT based model.
    keyword(s): Flow (Dynamics) , Temperature , Heat transfer , Computational fluid dynamics , Heat exchangers , Equations , Intersections , Reynolds number , Simulation AND Modeling ,
    • Download: (3.608Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Determination of the Number of Tube Rows to Obtain Closure for Volume Averaging Theory Based Model of Fin-and-Tube Heat Exchangers

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/146535
    Collections
    • Journal of Heat Transfer

    Show full item record

    contributor authorFeng Zhou
    contributor authorNicholas E. Hansen
    contributor authorDavid J. Geb
    contributor authorIvan Catton
    date accessioned2017-05-09T00:44:45Z
    date available2017-05-09T00:44:45Z
    date copyrightDecember, 2011
    date issued2011
    identifier issn0022-1481
    identifier otherJHTRAO-27928#121801_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/146535
    description abstractModeling of fin-and-tube heat exchangers based on the volume averaging theory (VAT) requires proper closure of the VAT based governing equations. Closure can be obtained from reasonable lower scale solutions of a computational fluid dynamics (CFD) code, which means the tube row number chosen should be large enough, so that the closure can be evaluated for a representative elementary volume (REV) that is, not affected by the entrance or recirculation at the outlet of the fin gap. To determine the number of tube rows, three-dimensional numerical simulations for plate fin-and-tube heat exchangers were performed, with the Reynolds number varying from 500 to 6000 and the number of tube rows varying from 1 to 9. A clear perspective of the variations of both overall and local fiction factor and the Nusselt number as the tube row number increases are presented. These variation trends are explained from the view point of the field synergy principle (FSP). Our investigation shows that 4 + 1 + 1 tube rows is the minimum number to get reasonable lower scale solutions. A computational domain including 5 + 2 + 2 tube rows is recommended, so that the closure formulas for drag resistance coefficient and heat transfer coefficient could be evaluated for the sixth and seventh elementary volumes to close the VAT based model.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDetermination of the Number of Tube Rows to Obtain Closure for Volume Averaging Theory Based Model of Fin-and-Tube Heat Exchangers
    typeJournal Paper
    journal volume133
    journal issue12
    journal titleJournal of Heat Transfer
    identifier doi10.1115/1.4004478
    journal fristpage121801
    identifier eissn1528-8943
    keywordsFlow (Dynamics)
    keywordsTemperature
    keywordsHeat transfer
    keywordsComputational fluid dynamics
    keywordsHeat exchangers
    keywordsEquations
    keywordsIntersections
    keywordsReynolds number
    keywordsSimulation AND Modeling
    treeJournal of Heat Transfer:;2011:;volume( 133 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian