    Simulation of a Chain of Collapsible Contracting Lymphangions With Progressive Valve Closure

    Source: Journal of Biomechanical Engineering:;2011:;volume( 133 ):;issue: 001::page 11008
    Author:
    C. D. Bertram
    ,
    J. E. Moore
    ,
    C. Macaskill
    DOI: 10.1115/1.4002799
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The aim of this investigation was to achieve the first step toward a comprehensive model of the lymphatic system. A numerical model has been constructed of a lymphatic vessel, consisting of a short series chain of contractile segments (lymphangions) and of intersegmental valves. The changing diameter of a segment governs the difference between the flows through inlet and outlet valves and is itself governed by a balance between transmural pressure and passive and active wall properties. The compliance of segments is maximal at intermediate diameters and decreases when the segments are subject to greatly positive or negative transmural pressure. Fluid flow is the result of time-varying active contraction causing diameter to reduce and is limited by segmental viscous and valvular resistance. The valves effect a smooth transition from low forward-flow resistance to high backflow resistance. Contraction occurs sequentially in successive lymphangions in the forward-flow direction. The behavior of chains of one to five lymphangions was investigated by means of pump function curves, with variation of valve opening parameters, maximum contractility, lymphangion size gradation, number of lymphangions, and phase delay between adjacent lymphangion contractions. The model was reasonably robust numerically, with mean flow-rate generally reducing as adverse pressure was increased. Sequential contraction was found to be much more efficient than synchronized contraction. At the highest adverse pressures, pumping failed by one of two mechanisms, depending on parameter settings: either mean leakback flow exceeded forward pumping or contraction failed to open the lymphangion outlet valve. Maximum pressure and maximum flow-rate were both sensitive to the contractile state; maximum pressure was also determined by the number of lymphangions in series. Maximum flow-rate was highly sensitive to the transmural pressure experienced by the most upstream lymphangions, suggesting that many feeding lymphatics would be needed to supply one downstream lymphangion chain pumping at optimal transmural pressure.
    keyword(s): Chain , Pumps , Valves , Pressure , Flow (Dynamics) , Electrical resistance AND Vessels ,
    • Download: (1.192Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Simulation of a Chain of Collapsible Contracting Lymphangions With Progressive Valve Closure

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/145504
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorC. D. Bertram
    contributor authorJ. E. Moore
    contributor authorC. Macaskill
    date accessioned2017-05-09T00:42:37Z
    date available2017-05-09T00:42:37Z
    date copyrightJanuary, 2011
    date issued2011
    identifier issn0148-0731
    identifier otherJBENDY-27188#011008_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/145504
    description abstractThe aim of this investigation was to achieve the first step toward a comprehensive model of the lymphatic system. A numerical model has been constructed of a lymphatic vessel, consisting of a short series chain of contractile segments (lymphangions) and of intersegmental valves. The changing diameter of a segment governs the difference between the flows through inlet and outlet valves and is itself governed by a balance between transmural pressure and passive and active wall properties. The compliance of segments is maximal at intermediate diameters and decreases when the segments are subject to greatly positive or negative transmural pressure. Fluid flow is the result of time-varying active contraction causing diameter to reduce and is limited by segmental viscous and valvular resistance. The valves effect a smooth transition from low forward-flow resistance to high backflow resistance. Contraction occurs sequentially in successive lymphangions in the forward-flow direction. The behavior of chains of one to five lymphangions was investigated by means of pump function curves, with variation of valve opening parameters, maximum contractility, lymphangion size gradation, number of lymphangions, and phase delay between adjacent lymphangion contractions. The model was reasonably robust numerically, with mean flow-rate generally reducing as adverse pressure was increased. Sequential contraction was found to be much more efficient than synchronized contraction. At the highest adverse pressures, pumping failed by one of two mechanisms, depending on parameter settings: either mean leakback flow exceeded forward pumping or contraction failed to open the lymphangion outlet valve. Maximum pressure and maximum flow-rate were both sensitive to the contractile state; maximum pressure was also determined by the number of lymphangions in series. Maximum flow-rate was highly sensitive to the transmural pressure experienced by the most upstream lymphangions, suggesting that many feeding lymphatics would be needed to supply one downstream lymphangion chain pumping at optimal transmural pressure.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleSimulation of a Chain of Collapsible Contracting Lymphangions With Progressive Valve Closure
    typeJournal Paper
    journal volume133
    journal issue1
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4002799
    journal fristpage11008
    identifier eissn1528-8951
    keywordsChain
    keywordsPumps
    keywordsValves
    keywordsPressure
    keywordsFlow (Dynamics)
    keywordsElectrical resistance AND Vessels
    treeJournal of Biomechanical Engineering:;2011:;volume( 133 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian