YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Medical Devices
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Medical Devices
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Irregular Bone Defect Detection and Device on Dental Implants

    Source: Journal of Medical Devices:;2010:;volume( 004 ):;issue: 002::page 27521
    Author:
    H.-B. Zhuang
    ,
    Min-Chun Pan
    DOI: 10.1115/1.3443175
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Dental implants are generally used in edentulous patients. The key issue of this dental surgery is the effective osseointegration of implants with spongy bone and cortical bone and then they become a part of loading structure. Current osseointegration detection devices only offer overall evaluation without the information of location and orientation of bone defects. This study is to develop detection techniques to measure the quantity as well as to locate the orientation of imperfection around bone-implant interface based on resonance frequency analysis (RFA). A noncontact measurement technique is performed with acoustic excitation through a loud-speaker and displacement response via a capacity-type pick-up. In the first and second series experiments, RFA is applied to estimate the orientation and quantity of irregular bone defects on various in-vitro faulty models. The variation in RF not only locates the orientation and depth of defects but also reflects the change of boundary conditions surrounding the defective models. According to these results, the detection technique to locate irregular osseointegration is established. Furthermore, the detection device to this end is proposed as well. The proposed examining approach and device are promising and able to assist dentists in dental implant surgery.
    • Download: (30.00Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Irregular Bone Defect Detection and Device on Dental Implants

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/144435
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorH.-B. Zhuang
    contributor authorMin-Chun Pan
    date accessioned2017-05-09T00:40:02Z
    date available2017-05-09T00:40:02Z
    date copyrightJune, 2010
    date issued2010
    identifier issn1932-6181
    identifier otherJMDOA4-28010#027521_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/144435
    description abstractDental implants are generally used in edentulous patients. The key issue of this dental surgery is the effective osseointegration of implants with spongy bone and cortical bone and then they become a part of loading structure. Current osseointegration detection devices only offer overall evaluation without the information of location and orientation of bone defects. This study is to develop detection techniques to measure the quantity as well as to locate the orientation of imperfection around bone-implant interface based on resonance frequency analysis (RFA). A noncontact measurement technique is performed with acoustic excitation through a loud-speaker and displacement response via a capacity-type pick-up. In the first and second series experiments, RFA is applied to estimate the orientation and quantity of irregular bone defects on various in-vitro faulty models. The variation in RF not only locates the orientation and depth of defects but also reflects the change of boundary conditions surrounding the defective models. According to these results, the detection technique to locate irregular osseointegration is established. Furthermore, the detection device to this end is proposed as well. The proposed examining approach and device are promising and able to assist dentists in dental implant surgery.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleIrregular Bone Defect Detection and Device on Dental Implants
    typeJournal Paper
    journal volume4
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.3443175
    journal fristpage27521
    identifier eissn1932-619X
    treeJournal of Medical Devices:;2010:;volume( 004 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian