    PneumoniaCheck: A Device for Sampling Lower Airway Aerosols

    Source: Journal of Medical Devices:;2010:;volume( 004 ):;issue: 004::page 41005
    Author:
    Tamera L. Scholz
    ,
    Larry J. Anderson
    ,
    David N. Ku
    ,
    Prem A. Midha
    DOI: 10.1115/1.4002760
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The pathogens causing pneumonia are difficult to identify because a high quality specimen from the lower lung is difficult to obtain. A new specimen collection device is designed to collect aerosol specimens selectively from the lower lung generated during deep coughing. The PneumoniaCheck device utilizes a separation reservoir and Venturi valve to segregate contents from the upper and lower airways. The device also includes several specially designed features to exclude oral contaminants from the sample and a filter to collect the aerosolized pathogens. Verification testing of PneumoniaCheck demonstrates effective separation of upper airway gas from the lower airway gas (p<0.0001) and exclusion of both liquid and viscous oral material (p<0.0001) from the collection chamber. The filters can collect 99.9997% of virus and bacteria sized particles from the sampled lower lung aerosols. The selective collection of specimens from the lower airway may aid in the diagnosis of specific pathogens causing pneumonia.
    keyword(s): Flow (Dynamics) , Separation (Technology) , Aerosols , Reservoirs , Sampling (Acoustical engineering) , Ethanol , Filters , Oxygen , Venturi tubes , Lung AND Valves ,
    • Download: (267.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      PneumoniaCheck: A Device for Sampling Lower Airway Aerosols

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/144374
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorTamera L. Scholz
    contributor authorLarry J. Anderson
    contributor authorDavid N. Ku
    contributor authorPrem A. Midha
    date accessioned2017-05-09T00:39:57Z
    date available2017-05-09T00:39:57Z
    date copyrightDecember, 2010
    date issued2010
    identifier issn1932-6181
    identifier otherJMDOA4-28014#041005_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/144374
    description abstractThe pathogens causing pneumonia are difficult to identify because a high quality specimen from the lower lung is difficult to obtain. A new specimen collection device is designed to collect aerosol specimens selectively from the lower lung generated during deep coughing. The PneumoniaCheck device utilizes a separation reservoir and Venturi valve to segregate contents from the upper and lower airways. The device also includes several specially designed features to exclude oral contaminants from the sample and a filter to collect the aerosolized pathogens. Verification testing of PneumoniaCheck demonstrates effective separation of upper airway gas from the lower airway gas (p<0.0001) and exclusion of both liquid and viscous oral material (p<0.0001) from the collection chamber. The filters can collect 99.9997% of virus and bacteria sized particles from the sampled lower lung aerosols. The selective collection of specimens from the lower airway may aid in the diagnosis of specific pathogens causing pneumonia.
    publisherThe American Society of Mechanical Engineers (ASME)
    titlePneumoniaCheck: A Device for Sampling Lower Airway Aerosols
    typeJournal Paper
    journal volume4
    journal issue4
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4002760
    journal fristpage41005
    identifier eissn1932-619X
    keywordsFlow (Dynamics)
    keywordsSeparation (Technology)
    keywordsAerosols
    keywordsReservoirs
    keywordsSampling (Acoustical engineering)
    keywordsEthanol
    keywordsFilters
    keywordsOxygen
    keywordsVenturi tubes
    keywordsLung AND Valves
    treeJournal of Medical Devices:;2010:;volume( 004 ):;issue: 004
    contenttypeFulltext