description abstractThe concept of the cyclic periodical mixing combustion process (, and , 2004, “Lean Blowout Limit and NOx-Production of a Premixed Sub-ppm-NOx Burner With Periodic Flue Gas Recirculation,” Proceedings of the ASME Turbo Expo 2004, Paper No. GT2004-53410; , and , 2006, “Lean Blowout Limit and NOx-Production of a Premixed Sub-ppm-NOx Burner With Periodic Recirculation of Combustion Products,” ASME J. Eng. Gas Turbines Power, 128(2), pp. 247–254) for the extension of the lean blowout limit had been implemented in an atmospheric experimental combustor for testing with both external perfect (, , and , 2006, “Operation Characteristics of a Premixed Sub-ppm NOx Burner With Periodical Recirculation of Combustion Products,” Proceedings of the ASME Turbo Expo 2006, Paper No. GT2006-90072) and technical (, , , and , 2007, “Development of a Fuel-Air Premixer for a Sub-ppm NOx Burner,” Proceedings of the ASME Turbo Expo 2007, Paper No. GT2007-27779) premixing of reactants. It had been tested with natural gas and has now been tested with a mixture of 70%vol of hydrogen and 30%vol of natural gas (98% CH4) as fuel. With natural gas the NOx emissions are unaffected by the limited technical premixing quality, as long as the air preheat is in the design range of the premixers (, , , and , 2007, “Development of a Fuel-Air Premixer for a Sub-ppm NOx Burner,” Proceedings of the ASME Turbo Expo 2007, Paper No. GT2007-27779). Then, for adiabatic flame temperatures of up to 1630 K NOx emissions are below 1 ppm(v) with CO emissions below 8 ppm(v) in the whole operation range of the test combustor (15% O2, dry). With the “70%volH2−30%volCH4” mixture the NOx emissions increase by nearly one order of magnitude. Then, NOx emissions below 7 ppm(v) (15% O2, dry) are achieved for adiabatic flame temperatures of up to 1600 K. They approach the 1 ppm(v) level only for flame temperatures below 1450 K. CO emissions are below 4 ppm(v). The reason for the increase in the NOx emissions is the higher reactivity of the mixture, which leads to earlier ignition in zones of still elevated unmixedness of reactants near the premixer-injector exits. This effect was investigated by chemical reactor network simulations analyzing a pressure effect and an additional chemical effect of hydrogen combustion on NOx formation.
publisherThe American Society of Mechanical Engineers (ASME)
titleEmission Characteristics of a Premixed Cyclic-Periodical-Mixing Combustor Operated With Hydrogen-Natural Gas Fuel Mixtures
typeJournal Paper
journal volume132
journal issue2
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.3124789
journal fristpage21505
identifier eissn0742-4795
keywordsCombustion
keywordsFuels
keywordsCombustion chambers
keywordsNatural gas
keywordsHydrogen
keywordsIgnition
keywordsMixtures
keywordsEmissions AND Temperature
treeJournal of Engineering for Gas Turbines and Power:;2010:;volume( 132 ):;issue: 002