Show simple item record

contributor authorJ. Jeffrey Moore
contributor authorRainer Kurz
contributor authorAugusto Garcia-Hernandez
contributor authorKlaus Brun
date accessioned2017-05-09T00:37:41Z
date available2017-05-09T00:37:41Z
date copyrightJune, 2010
date issued2010
identifier issn1528-8919
identifier otherJETPEZ-27116#062401_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/143186
description abstractThe transient behavior of compressor stations, particularly under rapidly changing conditions, is of vital interest to operators. Predicting transient behavior is an important factor in avoiding damage during events such as emergency shutdowns. A limited number of “accidental” data sets from compressor manufacturers and users are available in the public literature domain. A variety of simulations and modeling approaches have been presented over the last few years at industry conferences. The available experimental data is not of sufficient quality and resolution to properly compare predictions with analytical results or simulations available in current software packages. Necessary information about the compressor, driver, valves, and geometry of the system is often missing. Currently utilized software has not been adequately validated with full-scale realistic benchmark data, as this data is not available in the public domain. Modeling procedures and results of surge control system simulations seldom contain validation data achieved through actual testing. This type of transient test data for a dynamic surge condition is often difficult to obtain. The primary objective of this work is to develop experimental transient compressor surge data on a full-scale test facility, which would facilitate the verification and comparison of existing and future transient surge models. Results of the testing and model comparisons will be documented. Relevant, dimensionless parameters will be presented and validated utilizing the test data. Conclusions from the testing and recommendations for the transient analysis software will be provided.
publisherThe American Society of Mechanical Engineers (ASME)
titleExperimental Evaluation of the Transient Behavior of a Compressor Station During Emergency Shutdowns
typeJournal Paper
journal volume132
journal issue6
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.4000093
journal fristpage62401
identifier eissn0742-4795
keywordsFlow (Dynamics)
keywordsCompressors
keywordsValves
keywordsSurges
keywordsModeling
keywordsPressure AND Pipes
treeJournal of Engineering for Gas Turbines and Power:;2010:;volume( 132 ):;issue: 006