YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    The Biomechanics of Erections: Two- Versus One-Compartment Pressurized Vessel Modeling of the Penis

    Source: Journal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 012::page 121004
    Author:
    Ahmed M. Mohamed
    ,
    Arthur G. Erdman
    ,
    Gerald W. Timm
    DOI: 10.1115/1.4002794
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Previous biomechanical models of the penis simulated penile erections utilizing 2D geometry, simplified 3D geometry or made inaccurate assumptions altogether. These models designed the shaft of the penis as a one-compartment pressurized vessel fixed at one end when in reality it is a two-compartment pressurized vessel in which the compartments diverge as they enter the body and are fixed at two separate anatomic sites. This study utilizes the more anatomically correct two-compartment penile model to investigate erectile function. Simplified 2D and 3D models of the erect penis were developed using the finite element method with varying anatomical considerations for analyzing structural stresses, axial buckling, and lateral deformation. This study then validated the results by building and testing corresponding physical models. Finally, a more complex and anatomically accurate model of the penis was designed and analyzed. When subject to a lateral force of 0.5 N, the peak equivalent von Mises (EVM) stress in the two-compartment model increased by about 31.62%, while in the one-compartment model, the peak EVM stress increased by as high as 70.11%. The peak EVM stress was 149 kPa in the more complex and anatomically accurate penile model. When the perforated septum was removed, the peak EVM stress increased to 455 kPa. This study verified that there is significant difference between modeling the penis as a two- versus a one-compartment pressurized vessel. When subjected to external forces, a significant advantage was exhibited by two corporal based cavernosal bodies separated by a perforated septum as opposed to one corporal body. This is due to better structural integrity of the tunica albuginea when subjected to external forces.
    keyword(s): Deformation , Stress , Biomechanics , Modeling , Buckling , Vessels , Force AND Pressure ,
    • Download: (661.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      The Biomechanics of Erections: Two- Versus One-Compartment Pressurized Vessel Modeling of the Penis

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/142492
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorAhmed M. Mohamed
    contributor authorArthur G. Erdman
    contributor authorGerald W. Timm
    date accessioned2017-05-09T00:36:22Z
    date available2017-05-09T00:36:22Z
    date copyrightDecember, 2010
    date issued2010
    identifier issn0148-0731
    identifier otherJBENDY-27182#121004_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/142492
    description abstractPrevious biomechanical models of the penis simulated penile erections utilizing 2D geometry, simplified 3D geometry or made inaccurate assumptions altogether. These models designed the shaft of the penis as a one-compartment pressurized vessel fixed at one end when in reality it is a two-compartment pressurized vessel in which the compartments diverge as they enter the body and are fixed at two separate anatomic sites. This study utilizes the more anatomically correct two-compartment penile model to investigate erectile function. Simplified 2D and 3D models of the erect penis were developed using the finite element method with varying anatomical considerations for analyzing structural stresses, axial buckling, and lateral deformation. This study then validated the results by building and testing corresponding physical models. Finally, a more complex and anatomically accurate model of the penis was designed and analyzed. When subject to a lateral force of 0.5 N, the peak equivalent von Mises (EVM) stress in the two-compartment model increased by about 31.62%, while in the one-compartment model, the peak EVM stress increased by as high as 70.11%. The peak EVM stress was 149 kPa in the more complex and anatomically accurate penile model. When the perforated septum was removed, the peak EVM stress increased to 455 kPa. This study verified that there is significant difference between modeling the penis as a two- versus a one-compartment pressurized vessel. When subjected to external forces, a significant advantage was exhibited by two corporal based cavernosal bodies separated by a perforated septum as opposed to one corporal body. This is due to better structural integrity of the tunica albuginea when subjected to external forces.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleThe Biomechanics of Erections: Two- Versus One-Compartment Pressurized Vessel Modeling of the Penis
    typeJournal Paper
    journal volume132
    journal issue12
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4002794
    journal fristpage121004
    identifier eissn1528-8951
    keywordsDeformation
    keywordsStress
    keywordsBiomechanics
    keywordsModeling
    keywordsBuckling
    keywordsVessels
    keywordsForce AND Pressure
    treeJournal of Biomechanical Engineering:;2010:;volume( 132 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian