contributor author | Alok Dhungel | |
contributor author | Srinath V. Ekkad | |
contributor author | James Heidmann | |
contributor author | Yiping Lu | |
contributor author | Wynn Phillips | |
date accessioned | 2017-05-09T00:35:51Z | |
date available | 2017-05-09T00:35:51Z | |
date copyright | April, 2009 | |
date issued | 2009 | |
identifier issn | 0889-504X | |
identifier other | JOTUEI-28754#021007_1.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/142183 | |
description abstract | The primary focus of this paper is to study the film cooling performance for a row of cylindrical holes each supplemented with two symmetrical antivortex holes, which branch out from the main holes. The antivortex design was originally developed at NASA-Glenn Research Center by James Heidmann, coauthor of this paper. This “antivortex” design is unique in that it requires only easily machinable round holes, unlike shaped film cooling holes and other advanced concepts. The hole design is intended to counteract the detrimental vorticity associated with standard circular cross-section film cooling holes. The geometry and orientation of the antivortex holes greatly affect the cooling performance downstream, which is thoroughly investigated. By performing experiments at a single mainstream Reynolds number of 9683 based on the freestream velocity and film hole diameter at four different coolant-to-mainstream blowing ratios of 0.5, 1, 1.5, and 2 and using the transient IR thermography technique, detailed film cooling effectiveness and heat transfer coefficients are obtained simultaneously from a single test. When the antivortex holes are nearer the primary film cooling holes and are developing from the base of the primary holes, better film cooling is accomplished as compared to other antivortex hole orientations. When the antivortex holes are laid back in the upstream region, film cooling diminishes considerably. Although an enhancement in heat transfer coefficient is seen in cases with high film cooling effectiveness, the overall heat flux ratio as compared to standard cylindrical holes is much lower. Thus cases with antivortex holes placed near the main holes certainly show promising results. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Film Cooling From a Row of Holes Supplemented With Antivortex Holes | |
type | Journal Paper | |
journal volume | 131 | |
journal issue | 2 | |
journal title | Journal of Turbomachinery | |
identifier doi | 10.1115/1.2950059 | |
journal fristpage | 21007 | |
identifier eissn | 1528-8900 | |
keywords | Cooling | |
keywords | Coolants | |
keywords | Heat transfer coefficients | |
keywords | Temperature | |
keywords | Geometry | |
keywords | Flow (Dynamics) AND Thermography | |
tree | Journal of Turbomachinery:;2009:;volume( 131 ):;issue: 002 | |
contenttype | Fulltext | |