    Hydrodynamic Evaluation of a Minimally Invasive Heart Valve in an Isolated Aortic Root Using a Modified In Vitro Model

    Source: Journal of Medical Devices:;2009:;volume( 003 ):;issue: 001::page 11002
    Author:
    Qiang Wang
    ,
    Yasushi Kato
    ,
    Richard T. Schoephoerster
    ,
    Leonard Pinchuk
    ,
    Fernando Jaramillo
    DOI: 10.1115/1.3054378
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Implantation methods for commercially available heart valve prostheses require open-chest access to the heart to perform the suturing process. In order to alleviate this complicated surgical implant technique, a “stent-valve” design was developed that will provide a less cumbersome implantation method and therefore a less invasive access to the heart. The purpose of this study is to verify its hydrodynamic performance and migration characteristics to assess its feasibility for use as a replacement heart valve. Hydrodynamic evaluation of the novel stent-valve combination device was carried out using a Vivitro left heart simulator and by setting up a comparison with the same 19 mm trileaflet valve under a traditional implantation (suture) method. To assess implantation ability under normal physiological conditions, porcine aortic root tissue was mounted into the left heart simulator to replace the original glass sinus. A comparison experiment was conducted to study the change in the total compliance and resistance of the testing system using the modified Windkessel model. For the range of test conditions investigated, the stent-valve combination device produced an average pressure gradient of 41.2 mm Hg(±19.6 mm Hg), an average effective orifice area (EOA) of 1.06 cm2(±0.08 cm2), and an average regurgitation percentage of 4.5% (±3.3%), while the sutured valve produced an average pressure gradient of 48.7 mm Hg(±17.4 mm Hg), an average EOA of 0.88 cm2(±0.14 cm2), and an average regurgitation percentage of 0.8% (±0.4%). The total compliance and resistance of the system was 0.37 ml/mm Hg(±0.01 ml/mm Hg) and 1.1 mm Hg/ml/s(±0.29 mm Hg/ml/s), with the original Windkessel model, and 0.33 ml/mm Hg(±0.01 ml/mm Hg) and 1.1 mm Hg/ml/s(±0.24 mm Hg/ml/s) for the system with the aortic tissue. The stent-valve combination device has demonstrated favorable hydrodynamic performance when compared with the same trileaflet valve under the traditional suturing method, and the arterial stent makes it possible to secure the valve at its required position without migration.
    • Download: (476.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Hydrodynamic Evaluation of a Minimally Invasive Heart Valve in an Isolated Aortic Root Using a Modified In Vitro Model

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/141652
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorQiang Wang
    contributor authorYasushi Kato
    contributor authorRichard T. Schoephoerster
    contributor authorLeonard Pinchuk
    contributor authorFernando Jaramillo
    date accessioned2017-05-09T00:34:48Z
    date available2017-05-09T00:34:48Z
    date copyrightMarch, 2009
    date issued2009
    identifier issn1932-6181
    identifier otherJMDOA4-28000#011002_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/141652
    description abstractImplantation methods for commercially available heart valve prostheses require open-chest access to the heart to perform the suturing process. In order to alleviate this complicated surgical implant technique, a “stent-valve” design was developed that will provide a less cumbersome implantation method and therefore a less invasive access to the heart. The purpose of this study is to verify its hydrodynamic performance and migration characteristics to assess its feasibility for use as a replacement heart valve. Hydrodynamic evaluation of the novel stent-valve combination device was carried out using a Vivitro left heart simulator and by setting up a comparison with the same 19 mm trileaflet valve under a traditional implantation (suture) method. To assess implantation ability under normal physiological conditions, porcine aortic root tissue was mounted into the left heart simulator to replace the original glass sinus. A comparison experiment was conducted to study the change in the total compliance and resistance of the testing system using the modified Windkessel model. For the range of test conditions investigated, the stent-valve combination device produced an average pressure gradient of 41.2 mm Hg(±19.6 mm Hg), an average effective orifice area (EOA) of 1.06 cm2(±0.08 cm2), and an average regurgitation percentage of 4.5% (±3.3%), while the sutured valve produced an average pressure gradient of 48.7 mm Hg(±17.4 mm Hg), an average EOA of 0.88 cm2(±0.14 cm2), and an average regurgitation percentage of 0.8% (±0.4%). The total compliance and resistance of the system was 0.37 ml/mm Hg(±0.01 ml/mm Hg) and 1.1 mm Hg/ml/s(±0.29 mm Hg/ml/s), with the original Windkessel model, and 0.33 ml/mm Hg(±0.01 ml/mm Hg) and 1.1 mm Hg/ml/s(±0.24 mm Hg/ml/s) for the system with the aortic tissue. The stent-valve combination device has demonstrated favorable hydrodynamic performance when compared with the same trileaflet valve under the traditional suturing method, and the arterial stent makes it possible to secure the valve at its required position without migration.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleHydrodynamic Evaluation of a Minimally Invasive Heart Valve in an Isolated Aortic Root Using a Modified In Vitro Model
    typeJournal Paper
    journal volume3
    journal issue1
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.3054378
    journal fristpage11002
    identifier eissn1932-619X
    treeJournal of Medical Devices:;2009:;volume( 003 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian