    Effects of Design Parameters on the Sensitivity of a Micro-Cantilever Based Biosensor

    Source: Journal of Medical Devices:;2009:;volume( 003 ):;issue: 002::page 27521
    Author:
    S. Vidhya
    ,
    L. Mathew
    DOI: 10.1115/1.3136843
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Piezo-resistive actuation of a microcantilever induced by biomolecular binding such as DNA hybridization and antibody-antigen binding is an important principle useful in biosensing applications. As the magnitude of the forces exerted is small, increasing the sensitivity of the microcantilever becomes critical. In this paper, we are considering to achieve this by geometric variation of the cantilever. The sensitivity of the cantilever was improved so that the device can sense the presence of antigen even if the magnitude of surface-stresses over the microcantilever was very small. We consider a `T-shaped' cantilver that eliminates the disadvantages while improving the sensitivity simultaneously. Simulations for validation have been performed using Intellisuite software (a MEMS design and simulation package). The simulations reveal that the T-shaped microcantilver is almost as sensitive as a thin cantilever and has relatively very low buckling effect. Simulations also reveal that with an increase in thickness of the cantilever, there is a proportional decrease in the sensitivity. This paper presents an analytical modeling and simulation studies of a piezoresistive cantilever used as MEMS based biosensor for the detection of cardiac markers. Diagnosis of Myocardial Infarction was achieved by the nanomechanical deflection of the microcantilever due to adsorption of the Troponin I complex. The deflection of the microcantilever was measured in terms of the piezoresistive changes by implanting boron at the anchor point where there is maximum strain due to the adsorption of the analyte molecules. The biochemical interactions between the Cardiac Troponin I (cTnl) complex and the immobilized antibodies would cause change in resistance of the piezoresistor integrated at the anchor point. A ‘T’ shaped microcantilever design was proposed for the study. The distal end of the device was coated with gold. The sensitivity of the cantilever was improved so that the device can sense the presence of antigen even if the magnitude of surface-stresses over the microcantilever was very small. To obtain an application specific optimum design parameter and predict the cantilever performance. The miniaturization of the cantilever-based biosensor leads to significant advantages in the absolute device sensitivity.
    • Download: (37.79Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Effects of Design Parameters on the Sensitivity of a Micro-Cantilever Based Biosensor

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/141585
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorS. Vidhya
    contributor authorL. Mathew
    date accessioned2017-05-09T00:34:43Z
    date available2017-05-09T00:34:43Z
    date copyrightJune, 2009
    date issued2009
    identifier issn1932-6181
    identifier otherJMDOA4-28002#027521_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/141585
    description abstractPiezo-resistive actuation of a microcantilever induced by biomolecular binding such as DNA hybridization and antibody-antigen binding is an important principle useful in biosensing applications. As the magnitude of the forces exerted is small, increasing the sensitivity of the microcantilever becomes critical. In this paper, we are considering to achieve this by geometric variation of the cantilever. The sensitivity of the cantilever was improved so that the device can sense the presence of antigen even if the magnitude of surface-stresses over the microcantilever was very small. We consider a `T-shaped' cantilver that eliminates the disadvantages while improving the sensitivity simultaneously. Simulations for validation have been performed using Intellisuite software (a MEMS design and simulation package). The simulations reveal that the T-shaped microcantilver is almost as sensitive as a thin cantilever and has relatively very low buckling effect. Simulations also reveal that with an increase in thickness of the cantilever, there is a proportional decrease in the sensitivity. This paper presents an analytical modeling and simulation studies of a piezoresistive cantilever used as MEMS based biosensor for the detection of cardiac markers. Diagnosis of Myocardial Infarction was achieved by the nanomechanical deflection of the microcantilever due to adsorption of the Troponin I complex. The deflection of the microcantilever was measured in terms of the piezoresistive changes by implanting boron at the anchor point where there is maximum strain due to the adsorption of the analyte molecules. The biochemical interactions between the Cardiac Troponin I (cTnl) complex and the immobilized antibodies would cause change in resistance of the piezoresistor integrated at the anchor point. A ‘T’ shaped microcantilever design was proposed for the study. The distal end of the device was coated with gold. The sensitivity of the cantilever was improved so that the device can sense the presence of antigen even if the magnitude of surface-stresses over the microcantilever was very small. To obtain an application specific optimum design parameter and predict the cantilever performance. The miniaturization of the cantilever-based biosensor leads to significant advantages in the absolute device sensitivity.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEffects of Design Parameters on the Sensitivity of a Micro-Cantilever Based Biosensor
    typeJournal Paper
    journal volume3
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.3136843
    journal fristpage27521
    identifier eissn1932-619X
    treeJournal of Medical Devices:;2009:;volume( 003 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian