    Development of the Stiffenable Exoskeleton Device for a Colonoscopy

    Source: Journal of Medical Devices:;2009:;volume( 003 ):;issue: 002::page 27515
    Author:
    JungHun Choi
    ,
    R. H. Sturges
    DOI: 10.1115/1.3135242
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Colonoscopy provides a minimally invasive tool for examining and treating the colon without surgery, but current colonoscope designs still cause a degree of pain and mechanical trauma to the colon wall. The most common colonoscopes are long tubes inserted through the rectum with fiber optic lights, cameras, and biopsy tools on the distal end. The stiffness required to support these tools makes it difficult for the scopes to navigate the twisted path of the colon without causing mechanical trauma inside the colon wall or distorting its shape. The shaft of the colonoscope often causes looping (alpha, reverse alpha, or n), and it is very difficult to advance the distal tip of the colonoscope with looping. In order to avoid looping and minimize mechanical trauma, the author expanded on a design by Zehel et al., who proposed surrounding a flexible colonoscope with an external exoskeleton structure with controllable stiffness. The stiffenable exoskeleton device is comprised of rigid, articulating tubular units, which are stiffened or relaxed by four control cables. The stiffened or relaxed exoskeleton device guides navigation and provides stability for the colonoscope when it protrudes beyond the exoskeleton device for examination and procedures. This research determined the design requirements of such an exoskeleton device and tested requirements of such an exoskeleton device and tested its behavior in a colonoscopy training model. Moreover, the stiffenable exoskeleton device can be operated in purely a mechanical way, which is safe as a class II medical device, and no additional modification of the colonoscope is needed to use the stiffenable exoskeleton device. Colonoscopy training model is used to test the stiffenable exoskeleton device. First, the endoscopist inserted the colonoscope into the colonoscopy training model up to the end of the stiffenable exoskeleton device along the shaft of the colonoscope to the distal tip of the colonoscope, and then locked the stiffenable exoskeleton device and advanced the shaft of the colonoscope to examine the colon. When the distal tip reached the cecum, he or she unlocked the stiffenable exoskeleton device, retracted the shaft of the colonoscope and the stiffenable exoskeleton device, and checked for polyps or other colon disease. Also, the endoscopist can insert the stiffenable exoskeleton device and a colonoscope alternatively by stiffening and releasing the exoskeleton device. In that way, endoscopist can advance the colonoscope and the exoskeleton structure inch-by-inch without causing mechanical trauma in the rectum and the sigmoid colon. The endoscopist tested the stiffenable exoskeleton device using the colonoscopy training model and fulfilled its objectives. Several other diagnostic procedures involving the stomach, esophagus and the nose could also benefit due to the improvements provided by the stiffenable exoskeleton technology.
    • Download: (36.65Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Development of the Stiffenable Exoskeleton Device for a Colonoscopy

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/141572
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorJungHun Choi
    contributor authorR. H. Sturges
    date accessioned2017-05-09T00:34:42Z
    date available2017-05-09T00:34:42Z
    date copyrightJune, 2009
    date issued2009
    identifier issn1932-6181
    identifier otherJMDOA4-28002#027515_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/141572
    description abstractColonoscopy provides a minimally invasive tool for examining and treating the colon without surgery, but current colonoscope designs still cause a degree of pain and mechanical trauma to the colon wall. The most common colonoscopes are long tubes inserted through the rectum with fiber optic lights, cameras, and biopsy tools on the distal end. The stiffness required to support these tools makes it difficult for the scopes to navigate the twisted path of the colon without causing mechanical trauma inside the colon wall or distorting its shape. The shaft of the colonoscope often causes looping (alpha, reverse alpha, or n), and it is very difficult to advance the distal tip of the colonoscope with looping. In order to avoid looping and minimize mechanical trauma, the author expanded on a design by Zehel et al., who proposed surrounding a flexible colonoscope with an external exoskeleton structure with controllable stiffness. The stiffenable exoskeleton device is comprised of rigid, articulating tubular units, which are stiffened or relaxed by four control cables. The stiffened or relaxed exoskeleton device guides navigation and provides stability for the colonoscope when it protrudes beyond the exoskeleton device for examination and procedures. This research determined the design requirements of such an exoskeleton device and tested requirements of such an exoskeleton device and tested its behavior in a colonoscopy training model. Moreover, the stiffenable exoskeleton device can be operated in purely a mechanical way, which is safe as a class II medical device, and no additional modification of the colonoscope is needed to use the stiffenable exoskeleton device. Colonoscopy training model is used to test the stiffenable exoskeleton device. First, the endoscopist inserted the colonoscope into the colonoscopy training model up to the end of the stiffenable exoskeleton device along the shaft of the colonoscope to the distal tip of the colonoscope, and then locked the stiffenable exoskeleton device and advanced the shaft of the colonoscope to examine the colon. When the distal tip reached the cecum, he or she unlocked the stiffenable exoskeleton device, retracted the shaft of the colonoscope and the stiffenable exoskeleton device, and checked for polyps or other colon disease. Also, the endoscopist can insert the stiffenable exoskeleton device and a colonoscope alternatively by stiffening and releasing the exoskeleton device. In that way, endoscopist can advance the colonoscope and the exoskeleton structure inch-by-inch without causing mechanical trauma in the rectum and the sigmoid colon. The endoscopist tested the stiffenable exoskeleton device using the colonoscopy training model and fulfilled its objectives. Several other diagnostic procedures involving the stomach, esophagus and the nose could also benefit due to the improvements provided by the stiffenable exoskeleton technology.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDevelopment of the Stiffenable Exoskeleton Device for a Colonoscopy
    typeJournal Paper
    journal volume3
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.3135242
    journal fristpage27515
    identifier eissn1932-619X
    treeJournal of Medical Devices:;2009:;volume( 003 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian