Show simple item record

contributor authorYohan Kondo
contributor authorSonko Osawa
contributor authorMasaharu Komori
contributor authorOsamu Sato
contributor authorKazuyuki Sasajima
date accessioned2017-05-09T00:34:03Z
date available2017-05-09T00:34:03Z
date copyrightOctober, 2009
date issued2009
identifier issn1087-1357
identifier otherJMSEFK-28235#051016_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/141195
description abstractThe pitch accuracy of a gear is graded on the order of 0.1 μm in ISO 1328-1; therefore, it is necessary for gear measuring instruments (GMIs) to be able to measure gears with the required high accuracy. GMIs are evaluated by measuring a calibrated gear or a gearlike artifact. It is, however, difficult to obtain a measurement uncertainty of less than 0.1 μm. The reason for this difficulty is that a gear artifact has a form error and surface roughness, and that the measurement position on the gear face differs slightly from the calibrated position. In view of this situation, we propose a novel multiball artifact (MBA), which is composed of equally spaced pitch balls, a centering ball, and a datum plane. The pitch balls are assumed to act as gear teeth by calibrating the angular pitch between the centers of each pitch ball. The centering ball and the datum plane are used to set a reference axis of the virtual gear. We manufactured an MBA with the pitch balls arranged on a curvic coupling. The angular pitch deviation between the centers of each pitch ball was calibrated using a coordinate measuring machine (CMM) and adopting the multiple-orientation technique. A master gear was also calibrated for comparison. The measurement uncertainty for the cumulative angular pitch deviation was 0.45 arc sec for the MBA and 1.58 arc sec for the master gear. The MBA could be calibrated with small uncertainty compared with the master gear. After the calibration, a virtual gear of the MBA was built using the calibration value. The virtual gear was measured using the gear-measuring software on the CMM. The measurement value was equal within the range of uncertainty of calibration value. It is verified that the superiority of the MBA to the gear artifact is due to the following reasons: (1) The balls can be manufactured with an accuracy of several tens of nanometers. (2) The calibrated result for the MBA is almost independent of a probe-positioning error because the centers of each pitch ball can be measured at multiple points. (3) In setting the reference axis, the gear artifact generally uses a datum cylinder, in contrast, the MBA uses more accurate ball.
publisherThe American Society of Mechanical Engineers (ASME)
titleDevelopment of a Novel Artifact as a Reference for Gear Pitch Measuring Instruments
typeJournal Paper
journal volume131
journal issue5
journal titleJournal of Manufacturing Science and Engineering
identifier doi10.1115/1.4000104
journal fristpage51016
identifier eissn1528-8935
keywordsGears
keywordsCalibration
keywordsErrors AND Measuring instruments
treeJournal of Manufacturing Science and Engineering:;2009:;volume( 131 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record