YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Experimental Analysis of Model-Based Roentgen Stereophotogrammetric Analysis (MBRSA) on Four Typical Prosthesis Components

    Source: Journal of Biomechanical Engineering:;2009:;volume( 131 ):;issue: 004::page 41004
    Author:
    Frank Seehaus
    ,
    Bart L. Kaptein
    ,
    Henning Windhagen
    ,
    Christof Hurschler
    ,
    Judith Emmerich
    DOI: 10.1115/1.3072892
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Classical marker-based roentgen stereophotogrammetric analysis (RSA) is an accurate method of measuring in vivo implant migration. A disadvantage of the method is the necessity of placing tantalum markers on the implant, which constitutes additional manufacturing and certification effort. Model-based RSA (MBRSA) is a method by which pose-estimation of geometric surface-models of the implant is used to detect implant migration. The placement of prosthesis markers is thus no longer necessary. The accuracy of the pose-estimation algorithms used depends on the geometry of the prosthesis as well as the accuracy of the surface models used. The goal of this study was thus to evaluate the experimental accuracy and precision of the MBRSA method for four different, but typical prosthesis geometries, that are commonly implanted. Is there a relationship existing between the accuracy of MBRSA and prosthesis geometries? Four different prosthesis geometries were investigated: one femoral and one tibial total knee arthroplasty (TKA) component and two different femoral stem total hip arthroplasty (THA) components. An experimental phantom model was used to simulate two different implant migration protocols, whereby the implant was moved relative to the surrounding bone (relative prosthesis-bone motion (RM)), or, similar to the double-repeated measures performed to assess accuracy clinically, both the prosthesis and the surrounding bone model (zero relative prosthesis-bone motion (ZRM)) were moved. Motions were performed about three translational and three rotational axes, respectively. The maximum 95% confidence interval (CI) for MBRSA of all four prosthesis investigated was better than −0.034 to 0.107 mm for in-plane and −0.217 to 0.069 mm for out-of-plane translation, and from −0.038 deg to 0.162 deg for in-plane and from −1.316 deg to 0.071 deg for out-of-plane rotation, with no clear differences between the ZRM and RM protocols observed. Accuracy in translation was similar between TKA and THA components, whereas rotational accuracy about the long axis of the hip stem THA components was worse than the TKA components. The data suggest that accuracy and precision of MBRSA seem to be equivalent to the classical marker-based RSA method, at least for the nonsymmetric implant geometries investigated in this study. The model-based method thus allows the accurate measurement of implant migration without requiring prosthesis markers, and thus presents new opportunities for measuring implant migration where financial or geometric considerations of marker placement have thus far been prohibitive factors.
    keyword(s): Rotation , Motion , Bone , Prostheses , Phantoms , Accuracy and precision , Tantalum , Geometry , Experimental analysis AND Arthroplasty ,
    • Download: (1.235Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Experimental Analysis of Model-Based Roentgen Stereophotogrammetric Analysis (MBRSA) on Four Typical Prosthesis Components

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/139971
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorFrank Seehaus
    contributor authorBart L. Kaptein
    contributor authorHenning Windhagen
    contributor authorChristof Hurschler
    contributor authorJudith Emmerich
    date accessioned2017-05-09T00:31:45Z
    date available2017-05-09T00:31:45Z
    date copyrightApril, 2009
    date issued2009
    identifier issn0148-0731
    identifier otherJBENDY-26924#041004_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/139971
    description abstractClassical marker-based roentgen stereophotogrammetric analysis (RSA) is an accurate method of measuring in vivo implant migration. A disadvantage of the method is the necessity of placing tantalum markers on the implant, which constitutes additional manufacturing and certification effort. Model-based RSA (MBRSA) is a method by which pose-estimation of geometric surface-models of the implant is used to detect implant migration. The placement of prosthesis markers is thus no longer necessary. The accuracy of the pose-estimation algorithms used depends on the geometry of the prosthesis as well as the accuracy of the surface models used. The goal of this study was thus to evaluate the experimental accuracy and precision of the MBRSA method for four different, but typical prosthesis geometries, that are commonly implanted. Is there a relationship existing between the accuracy of MBRSA and prosthesis geometries? Four different prosthesis geometries were investigated: one femoral and one tibial total knee arthroplasty (TKA) component and two different femoral stem total hip arthroplasty (THA) components. An experimental phantom model was used to simulate two different implant migration protocols, whereby the implant was moved relative to the surrounding bone (relative prosthesis-bone motion (RM)), or, similar to the double-repeated measures performed to assess accuracy clinically, both the prosthesis and the surrounding bone model (zero relative prosthesis-bone motion (ZRM)) were moved. Motions were performed about three translational and three rotational axes, respectively. The maximum 95% confidence interval (CI) for MBRSA of all four prosthesis investigated was better than −0.034 to 0.107 mm for in-plane and −0.217 to 0.069 mm for out-of-plane translation, and from −0.038 deg to 0.162 deg for in-plane and from −1.316 deg to 0.071 deg for out-of-plane rotation, with no clear differences between the ZRM and RM protocols observed. Accuracy in translation was similar between TKA and THA components, whereas rotational accuracy about the long axis of the hip stem THA components was worse than the TKA components. The data suggest that accuracy and precision of MBRSA seem to be equivalent to the classical marker-based RSA method, at least for the nonsymmetric implant geometries investigated in this study. The model-based method thus allows the accurate measurement of implant migration without requiring prosthesis markers, and thus presents new opportunities for measuring implant migration where financial or geometric considerations of marker placement have thus far been prohibitive factors.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleExperimental Analysis of Model-Based Roentgen Stereophotogrammetric Analysis (MBRSA) on Four Typical Prosthesis Components
    typeJournal Paper
    journal volume131
    journal issue4
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.3072892
    journal fristpage41004
    identifier eissn1528-8951
    keywordsRotation
    keywordsMotion
    keywordsBone
    keywordsProstheses
    keywordsPhantoms
    keywordsAccuracy and precision
    keywordsTantalum
    keywordsGeometry
    keywordsExperimental analysis AND Arthroplasty
    treeJournal of Biomechanical Engineering:;2009:;volume( 131 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian