    Effect of Mechanical Loading on Electrical Conductivity in Human Intervertebral Disk

    Source: Journal of Biomechanical Engineering:;2009:;volume( 131 ):;issue: 005::page 54505
    Author:
    Alicia R. Jackson
    ,
    Francesco Travascio
    ,
    Wei Yong Gu
    DOI: 10.1115/1.3116152
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The intervertebral disk (IVD), characterized as a charged, hydrated soft tissue, is the largest avascular structure in the body. Mechanical loading to the disk results in electromechanical transduction phenomenon as well as altered transport properties. Electrical conductivity is a material property of tissue depending on ion concentrations and diffusivities, which are in turn functions of tissue composition and structure. The aim of this study was to investigate the effect of mechanical loading on electrical behavior in human IVD tissues. We hypothesized that electrical conductivity in human IVD is strain-dependent, due to change in tissue composition caused by compression, and inhomogeneous, due to tissue structure and composition. We also hypothesized that conductivity in human annulus fibrosus (AF) is anisotropic, due to the layered structure of the tissue. Three lumbar IVDs were harvested from three human spines. From each disk, four AF specimens were prepared in each of the three principal directions (axial, circumferential, and radial), and four axial nucleus pulposus (NP) specimens were prepared. Conductivity was determined using a four-wire sense-current method and a custom-designed apparatus by measuring the resistance across the sample. Resistance measurements were taken at three levels of compression (0%, 10%, and 20%). Scanning electron microscopy (SEM) images of the human AF tissue were obtained in order to correlate tissue structure with conductivity results. Increasing compressive strain significantly decreased conductivity for all groups (p<0.05, analysis of variance (ANOVA)). Additionally, specimen orientation significantly affected electrical conductivity in the AF tissue, with conductivity in the radial direction being significantly lower than that in the axial or circumferential directions at all levels of compressive strain (p<0.05, ANOVA). Finally, conductivity in the NP tissue was significantly higher than that in the AF tissue (p<0.05, ANOVA). SEM images of the AF tissues showed evidence of microtubes orientated in the axial and circumferential directions, but not in the radial direction. This may suggest a relationship between tissue morphology and the anisotropic behavior of conductivity in the AF. The results of this investigation demonstrate that electrical conductivity in human IVD is strain-dependent and inhomogeneous, and that conductivity in the human AF tissue is anisotropic (i.e., direction-dependent). This anisotropic behavior is correlated with tissue structure shown in SEM images. This study provides important information regarding the effects of mechanical loading on solute transport and electrical behavior in IVD tissues.
    keyword(s): Compression , Conductivity , Water , Intervertebral discs , Electrical conductivity , Biological tissues AND Scanning electron microscopy ,
    • Download: (406.1Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Effect of Mechanical Loading on Electrical Conductivity in Human Intervertebral Disk

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/139965
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorAlicia R. Jackson
    contributor authorFrancesco Travascio
    contributor authorWei Yong Gu
    date accessioned2017-05-09T00:31:44Z
    date available2017-05-09T00:31:44Z
    date copyrightMay, 2009
    date issued2009
    identifier issn0148-0731
    identifier otherJBENDY-26947#054505_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/139965
    description abstractThe intervertebral disk (IVD), characterized as a charged, hydrated soft tissue, is the largest avascular structure in the body. Mechanical loading to the disk results in electromechanical transduction phenomenon as well as altered transport properties. Electrical conductivity is a material property of tissue depending on ion concentrations and diffusivities, which are in turn functions of tissue composition and structure. The aim of this study was to investigate the effect of mechanical loading on electrical behavior in human IVD tissues. We hypothesized that electrical conductivity in human IVD is strain-dependent, due to change in tissue composition caused by compression, and inhomogeneous, due to tissue structure and composition. We also hypothesized that conductivity in human annulus fibrosus (AF) is anisotropic, due to the layered structure of the tissue. Three lumbar IVDs were harvested from three human spines. From each disk, four AF specimens were prepared in each of the three principal directions (axial, circumferential, and radial), and four axial nucleus pulposus (NP) specimens were prepared. Conductivity was determined using a four-wire sense-current method and a custom-designed apparatus by measuring the resistance across the sample. Resistance measurements were taken at three levels of compression (0%, 10%, and 20%). Scanning electron microscopy (SEM) images of the human AF tissue were obtained in order to correlate tissue structure with conductivity results. Increasing compressive strain significantly decreased conductivity for all groups (p<0.05, analysis of variance (ANOVA)). Additionally, specimen orientation significantly affected electrical conductivity in the AF tissue, with conductivity in the radial direction being significantly lower than that in the axial or circumferential directions at all levels of compressive strain (p<0.05, ANOVA). Finally, conductivity in the NP tissue was significantly higher than that in the AF tissue (p<0.05, ANOVA). SEM images of the AF tissues showed evidence of microtubes orientated in the axial and circumferential directions, but not in the radial direction. This may suggest a relationship between tissue morphology and the anisotropic behavior of conductivity in the AF. The results of this investigation demonstrate that electrical conductivity in human IVD is strain-dependent and inhomogeneous, and that conductivity in the human AF tissue is anisotropic (i.e., direction-dependent). This anisotropic behavior is correlated with tissue structure shown in SEM images. This study provides important information regarding the effects of mechanical loading on solute transport and electrical behavior in IVD tissues.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEffect of Mechanical Loading on Electrical Conductivity in Human Intervertebral Disk
    typeJournal Paper
    journal volume131
    journal issue5
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.3116152
    journal fristpage54505
    identifier eissn1528-8951
    keywordsCompression
    keywordsConductivity
    keywordsWater
    keywordsIntervertebral discs
    keywordsElectrical conductivity
    keywordsBiological tissues AND Scanning electron microscopy
    treeJournal of Biomechanical Engineering:;2009:;volume( 131 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian