YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Parametric Finite Element Analysis of Physical Stimuli Resulting From Mechanical Stimulation of Tissue Engineered Cartilage

    Source: Journal of Biomechanical Engineering:;2009:;volume( 131 ):;issue: 006::page 61014
    Author:
    Omotunde M. Babalola
    ,
    Lawrence J. Bonassar
    DOI: 10.1115/1.3128672
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: While mechanical stimulation of cells seeded within scaffolds is widely thought to be beneficial, the amount of benefit observed is highly variable between experimental systems. Although studies have investigated specific experimental loading protocols thought to be advantageous for cartilage growth, less is known about the physical stimuli (e.g., pressures, velocities, and local strains) cells experience during these experiments. This study used results of a literature survey, which looked for patterns in the efficacy of mechanical stimulation of chondrocyte seeded scaffolds, to inform the modeling of spatial patterns of physical stimuli present in mechanically stimulated constructs. The literature survey revealed a large variation in conditions used in mechanical loading studies, with a peak to peak strain of 10% (i.e., the maximum amount of deformation experienced by the scaffold) at 1 Hz on agarose scaffolds being the most frequently studied parameters and scaffold. This loading frequency was then used as the basis for simulation in the finite element analyses. 2D axisymmetric finite element models of 2×4 mm2 scaffolds with 360 modulus/permeability combinations were constructed using COMSOL MULTIPHYSICS software. A time dependent coupled pore pressure/effective stress analysis was used to model fluid/solid interactions in the scaffolds upon loading. Loading was simulated using an impermeable frictionless loader on the top boundary with fluid and solid displacement confined to the radial axis. As expected, all scaffold materials exhibited classic poro-elastic behavior having pressurized cores with low fluid flow and edges with high radial fluid velocities. Under the simulation parameters of this study, PEG scaffolds had the highest pressure and radial fluid velocity but also the lowest shear stress and radial strain. Chitosan and KLD-12 simulated scaffold materials had the lowest radial strains and fluid velocities, with collagen scaffolds having the lowest pressures. Parametric analysis showed maximum peak pressures within the scaffold to be more dependent on scaffold modulus than on permeability and velocities to depend on both scaffold properties similarly. The dependence of radial strain on permeability or modulus was more complex; maximum strains occurred at lower permeabilities and moduli, and the lowest strain occurred at the stiffest most permeable scaffold. Shear stresses within all scaffolds were negligible. These results give insight into the large variations in metabolic response seen in studies involving mechanical stimulation of cell-seeded constructs, where the same loading conditions produce very different results due to the differences in material properties.
    keyword(s): Fluids , Permeability , Stress , Biological tissues , Finite element analysis , Finite element model , Cartilage , Shear (Mechanics) , Materials properties , Chondrocytes , Agar , Pressure AND Fluid dynamics ,
    • Download: (775.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Parametric Finite Element Analysis of Physical Stimuli Resulting From Mechanical Stimulation of Tissue Engineered Cartilage

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/139938
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorOmotunde M. Babalola
    contributor authorLawrence J. Bonassar
    date accessioned2017-05-09T00:31:41Z
    date available2017-05-09T00:31:41Z
    date copyrightJune, 2009
    date issued2009
    identifier issn0148-0731
    identifier otherJBENDY-26966#061014_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/139938
    description abstractWhile mechanical stimulation of cells seeded within scaffolds is widely thought to be beneficial, the amount of benefit observed is highly variable between experimental systems. Although studies have investigated specific experimental loading protocols thought to be advantageous for cartilage growth, less is known about the physical stimuli (e.g., pressures, velocities, and local strains) cells experience during these experiments. This study used results of a literature survey, which looked for patterns in the efficacy of mechanical stimulation of chondrocyte seeded scaffolds, to inform the modeling of spatial patterns of physical stimuli present in mechanically stimulated constructs. The literature survey revealed a large variation in conditions used in mechanical loading studies, with a peak to peak strain of 10% (i.e., the maximum amount of deformation experienced by the scaffold) at 1 Hz on agarose scaffolds being the most frequently studied parameters and scaffold. This loading frequency was then used as the basis for simulation in the finite element analyses. 2D axisymmetric finite element models of 2×4 mm2 scaffolds with 360 modulus/permeability combinations were constructed using COMSOL MULTIPHYSICS software. A time dependent coupled pore pressure/effective stress analysis was used to model fluid/solid interactions in the scaffolds upon loading. Loading was simulated using an impermeable frictionless loader on the top boundary with fluid and solid displacement confined to the radial axis. As expected, all scaffold materials exhibited classic poro-elastic behavior having pressurized cores with low fluid flow and edges with high radial fluid velocities. Under the simulation parameters of this study, PEG scaffolds had the highest pressure and radial fluid velocity but also the lowest shear stress and radial strain. Chitosan and KLD-12 simulated scaffold materials had the lowest radial strains and fluid velocities, with collagen scaffolds having the lowest pressures. Parametric analysis showed maximum peak pressures within the scaffold to be more dependent on scaffold modulus than on permeability and velocities to depend on both scaffold properties similarly. The dependence of radial strain on permeability or modulus was more complex; maximum strains occurred at lower permeabilities and moduli, and the lowest strain occurred at the stiffest most permeable scaffold. Shear stresses within all scaffolds were negligible. These results give insight into the large variations in metabolic response seen in studies involving mechanical stimulation of cell-seeded constructs, where the same loading conditions produce very different results due to the differences in material properties.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleParametric Finite Element Analysis of Physical Stimuli Resulting From Mechanical Stimulation of Tissue Engineered Cartilage
    typeJournal Paper
    journal volume131
    journal issue6
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.3128672
    journal fristpage61014
    identifier eissn1528-8951
    keywordsFluids
    keywordsPermeability
    keywordsStress
    keywordsBiological tissues
    keywordsFinite element analysis
    keywordsFinite element model
    keywordsCartilage
    keywordsShear (Mechanics)
    keywordsMaterials properties
    keywordsChondrocytes
    keywordsAgar
    keywordsPressure AND Fluid dynamics
    treeJournal of Biomechanical Engineering:;2009:;volume( 131 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian