    Measuring Luxation of Dental Implants In Vitro

    Source: Journal of Medical Devices:;2008:;volume( 002 ):;issue: 001::page 14501
    Author:
    Horea T. Ilieş
    ,
    Dennis Flanagan
    ,
    Matthew Raby
    ,
    Richard Stevenson
    DOI: 10.1115/1.2889057
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Loading of dental implants immediately after placement is an important attribute for the patients receiving the implants, but may induce a failure in the osseointegration of the implant. Even though the loading required to induce such failures is currently unknown, it is estimated that the osseointegration may fail if an implant is luxated in bone by more than 50μm. Therefore, the ability to measure this loading can provide the practicing dentist with critical information in estimating the functional life of a newly placed implant. This paper discusses the design and fabrication of a cost-effective test setup for measuring the amount of horizontal force required to displace a nonosseointegrated implant, and presents the results of our pilot in vitro load measurements for dental implants mounted in a bovine mandible. Although the sample size of our measurements is not statistically significant, the initial data show that the amount of horizontal force required to displace a 4.3×13mm implant by 50μm is in the order of 150N, and therefore the implant may fail to osseointegrate for biting forces that are as low as 440N, which is about half of the typical biting force of an adult in the molar area. One implication of our study is that implants having smaller diameters may move and fail to osseointegrate for even lower biting forces. Furthermore, our work represents the first steps in developing appropriate metrics to correlate the measured biting force generated by a patient with his or her candidacy for immediate functional implant loading.
    keyword(s): Bone , Design , Testing , Force , Failure , Displacement , Stress AND Measurement ,
    • Download: (263.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Measuring Luxation of Dental Implants In Vitro

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/139095
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorHorea T. Ilieş
    contributor authorDennis Flanagan
    contributor authorMatthew Raby
    contributor authorRichard Stevenson
    date accessioned2017-05-09T00:30:03Z
    date available2017-05-09T00:30:03Z
    date copyrightMarch, 2008
    date issued2008
    identifier issn1932-6181
    identifier otherJMDOA4-27988#014501_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/139095
    description abstractLoading of dental implants immediately after placement is an important attribute for the patients receiving the implants, but may induce a failure in the osseointegration of the implant. Even though the loading required to induce such failures is currently unknown, it is estimated that the osseointegration may fail if an implant is luxated in bone by more than 50μm. Therefore, the ability to measure this loading can provide the practicing dentist with critical information in estimating the functional life of a newly placed implant. This paper discusses the design and fabrication of a cost-effective test setup for measuring the amount of horizontal force required to displace a nonosseointegrated implant, and presents the results of our pilot in vitro load measurements for dental implants mounted in a bovine mandible. Although the sample size of our measurements is not statistically significant, the initial data show that the amount of horizontal force required to displace a 4.3×13mm implant by 50μm is in the order of 150N, and therefore the implant may fail to osseointegrate for biting forces that are as low as 440N, which is about half of the typical biting force of an adult in the molar area. One implication of our study is that implants having smaller diameters may move and fail to osseointegrate for even lower biting forces. Furthermore, our work represents the first steps in developing appropriate metrics to correlate the measured biting force generated by a patient with his or her candidacy for immediate functional implant loading.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleMeasuring Luxation of Dental Implants In Vitro
    typeJournal Paper
    journal volume2
    journal issue1
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.2889057
    journal fristpage14501
    identifier eissn1932-619X
    keywordsBone
    keywordsDesign
    keywordsTesting
    keywordsForce
    keywordsFailure
    keywordsDisplacement
    keywordsStress AND Measurement
    treeJournal of Medical Devices:;2008:;volume( 002 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian