contributor author | Horea T. Ilieş | |
contributor author | Dennis Flanagan | |
contributor author | Matthew Raby | |
contributor author | Richard Stevenson | |
date accessioned | 2017-05-09T00:30:03Z | |
date available | 2017-05-09T00:30:03Z | |
date copyright | March, 2008 | |
date issued | 2008 | |
identifier issn | 1932-6181 | |
identifier other | JMDOA4-27988#014501_1.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/139095 | |
description abstract | Loading of dental implants immediately after placement is an important attribute for the patients receiving the implants, but may induce a failure in the osseointegration of the implant. Even though the loading required to induce such failures is currently unknown, it is estimated that the osseointegration may fail if an implant is luxated in bone by more than 50μm. Therefore, the ability to measure this loading can provide the practicing dentist with critical information in estimating the functional life of a newly placed implant. This paper discusses the design and fabrication of a cost-effective test setup for measuring the amount of horizontal force required to displace a nonosseointegrated implant, and presents the results of our pilot in vitro load measurements for dental implants mounted in a bovine mandible. Although the sample size of our measurements is not statistically significant, the initial data show that the amount of horizontal force required to displace a 4.3×13mm implant by 50μm is in the order of 150N, and therefore the implant may fail to osseointegrate for biting forces that are as low as 440N, which is about half of the typical biting force of an adult in the molar area. One implication of our study is that implants having smaller diameters may move and fail to osseointegrate for even lower biting forces. Furthermore, our work represents the first steps in developing appropriate metrics to correlate the measured biting force generated by a patient with his or her candidacy for immediate functional implant loading. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Measuring Luxation of Dental Implants In Vitro | |
type | Journal Paper | |
journal volume | 2 | |
journal issue | 1 | |
journal title | Journal of Medical Devices | |
identifier doi | 10.1115/1.2889057 | |
journal fristpage | 14501 | |
identifier eissn | 1932-619X | |
keywords | Bone | |
keywords | Design | |
keywords | Testing | |
keywords | Force | |
keywords | Failure | |
keywords | Displacement | |
keywords | Stress AND Measurement | |
tree | Journal of Medical Devices:;2008:;volume( 002 ):;issue: 001 | |
contenttype | Fulltext | |