    A Calibration Procedure for a Bone Loading System

    Source: Journal of Medical Devices:;2008:;volume( 002 ):;issue: 001::page 11006
    Author:
    Sylvana García-Rodríguez
    ,
    Everett L. Smith
    ,
    Heidi-Lynn Ploeg
    DOI: 10.1115/1.2889059
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Trabecular bone tissue is a three-dimensional structure that is difficult to duplicate with in vitro cell cultures or animal models. In an attempt to better understand the underlying mechanisms of tissue response to load, a system to load isolated bone preparations was developed. This ex vivo bone culture and loading system, given the name of ZETOS, compressively loads trabecular bone (10mm diameter, 5.0mm height) to evaluate its morphological and physiological responses while keeping cells viable. Compliance of the system may change with time, thus requiring recalibration. The purpose of this research was to develop and validate a recalibration protocol for the ZETOS system. Ten reference bodies (RBs) were designed and machined out of aluminum 7075-T6, with a structural rigidity range representative of trabecular bone (0.628–28.3N∕μm, or apparent elastic modulus of 40MPa–1.80GPa). Finite element analysis (FEA) was used to calculate the rigidity of each RB and was validated with physical testing in a universal testing machine. Results from FEA were then used to calibrate the system and relate force, piezoelectric actuator expansion, and specimen compressive deformation through a surface generated by spline interpolation, thus creating a calibration table. Calibration of ZETOS was verified by testing the RBs as well as three custom-made, metal springs and comparing measured rigidity to that calculated by FEA. Mean percent difference of FEA results with respect to those from physical testing was 3.28%. The mean percent difference of RB rigidity found with ZETOS with respect to rigidity found with FEA was 1.12% and for the metal springs, the mean percent difference was 1.74%. The calibration procedure for the ZETOS bone loading system has been successfully applied and verified. The use of RBs and FEA allows users to easily and periodically evaluate and recalibrate the system. Accuracy in studies of human bone mechanotransduction in a controlled environment can therefore be achieved. The recalibration procedure is relevant for other ZETOS users and may serve as the basis for calibration of other testing systems for small specimens of compliant materials.
    keyword(s): Bone , Finite element analysis , Testing , Calibration , Stiffness , Stress , Force , Deformation AND Design ,
    • Download: (210.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Calibration Procedure for a Bone Loading System

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/139093
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorSylvana García-Rodríguez
    contributor authorEverett L. Smith
    contributor authorHeidi-Lynn Ploeg
    date accessioned2017-05-09T00:30:03Z
    date available2017-05-09T00:30:03Z
    date copyrightMarch, 2008
    date issued2008
    identifier issn1932-6181
    identifier otherJMDOA4-27988#011006_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/139093
    description abstractTrabecular bone tissue is a three-dimensional structure that is difficult to duplicate with in vitro cell cultures or animal models. In an attempt to better understand the underlying mechanisms of tissue response to load, a system to load isolated bone preparations was developed. This ex vivo bone culture and loading system, given the name of ZETOS, compressively loads trabecular bone (10mm diameter, 5.0mm height) to evaluate its morphological and physiological responses while keeping cells viable. Compliance of the system may change with time, thus requiring recalibration. The purpose of this research was to develop and validate a recalibration protocol for the ZETOS system. Ten reference bodies (RBs) were designed and machined out of aluminum 7075-T6, with a structural rigidity range representative of trabecular bone (0.628–28.3N∕μm, or apparent elastic modulus of 40MPa–1.80GPa). Finite element analysis (FEA) was used to calculate the rigidity of each RB and was validated with physical testing in a universal testing machine. Results from FEA were then used to calibrate the system and relate force, piezoelectric actuator expansion, and specimen compressive deformation through a surface generated by spline interpolation, thus creating a calibration table. Calibration of ZETOS was verified by testing the RBs as well as three custom-made, metal springs and comparing measured rigidity to that calculated by FEA. Mean percent difference of FEA results with respect to those from physical testing was 3.28%. The mean percent difference of RB rigidity found with ZETOS with respect to rigidity found with FEA was 1.12% and for the metal springs, the mean percent difference was 1.74%. The calibration procedure for the ZETOS bone loading system has been successfully applied and verified. The use of RBs and FEA allows users to easily and periodically evaluate and recalibrate the system. Accuracy in studies of human bone mechanotransduction in a controlled environment can therefore be achieved. The recalibration procedure is relevant for other ZETOS users and may serve as the basis for calibration of other testing systems for small specimens of compliant materials.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Calibration Procedure for a Bone Loading System
    typeJournal Paper
    journal volume2
    journal issue1
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.2889059
    journal fristpage11006
    identifier eissn1932-619X
    keywordsBone
    keywordsFinite element analysis
    keywordsTesting
    keywordsCalibration
    keywordsStiffness
    keywordsStress
    keywordsForce
    keywordsDeformation AND Design
    treeJournal of Medical Devices:;2008:;volume( 002 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian