    The Effect of Stent Design on the Restenosis Rate

    Source: Journal of Medical Devices:;2008:;volume( 002 ):;issue: 002::page 27526
    Author:
    Aswini K. Muttyam
    ,
    Linxia Gu
    DOI: 10.1115/1.2934540
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Within 6months from the initial procedure, restenosis is observed in 40% of the cases treated with coronary stenting. Exact reasons for restenosis are yet to be explored. Stenting is a mechanical process which causes large stress in the arterial wall. This may lead to the activation of stent related stenosis. The primary objective of this study is to investigate the relation between the stresses developed in the arterial wall and the restenosis rate. A three-dimensional model based on finite element method has been built which includes the stent, the plaque and the artery. The simulated result shows high stress concentrations at the contact areas of the stent and the plaque. The over flaring of the end struts causing arterial trauma may lead to restenosis.
    • Download: (25.69Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      The Effect of Stent Design on the Restenosis Rate

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/139032
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorAswini K. Muttyam
    contributor authorLinxia Gu
    date accessioned2017-05-09T00:29:57Z
    date available2017-05-09T00:29:57Z
    date copyrightJune, 2008
    date issued2008
    identifier issn1932-6181
    identifier otherJMDOA4-27991#027526_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/139032
    description abstractWithin 6months from the initial procedure, restenosis is observed in 40% of the cases treated with coronary stenting. Exact reasons for restenosis are yet to be explored. Stenting is a mechanical process which causes large stress in the arterial wall. This may lead to the activation of stent related stenosis. The primary objective of this study is to investigate the relation between the stresses developed in the arterial wall and the restenosis rate. A three-dimensional model based on finite element method has been built which includes the stent, the plaque and the artery. The simulated result shows high stress concentrations at the contact areas of the stent and the plaque. The over flaring of the end struts causing arterial trauma may lead to restenosis.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleThe Effect of Stent Design on the Restenosis Rate
    typeJournal Paper
    journal volume2
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.2934540
    journal fristpage27526
    identifier eissn1932-619X
    treeJournal of Medical Devices:;2008:;volume( 002 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian