    Patient-Specific Compliant Vessel Manufacturing Using Dip-Spin Coating of Rapid Prototyped Molds

    Source: Journal of Manufacturing Science and Engineering:;2008:;volume( 130 ):;issue: 005::page 51008
    Author:
    Karina Arcaute
    ,
    Ryan B. Wicker
    DOI: 10.1115/1.2898839
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A procedure for manufacturing cardiovascular system models using patient-specific data, rapid prototyping, and a multistep dip-spin coating process is presented here. Improvements to a previously developed process permitted the fabrication of flexible complex vascular replicas. The primary improvement included the development of a two-axis rotation mechanism that enabled a pseudorandom rotation of the coated mold in space, providing uniform coats. Other improvements included the use of a low viscosity (1500–2000cP) silicone solution that allowed for complete coverage of the mold, and developing a procedure for fixing defects. The dip-spin coating procedure was shown to be effective for the manufacture of compliant cardiovascular membranes, such as an arterial bypass graft with an internal flow passage and an abdominal aorta with nonuniform radial geometry, tapered diameters, bifurcations, and small branches. Results from a design of experiments comparing two dipping setups demonstrated that horizontally dipping the model produced coatings with more uniform thicknesses along the length of the model when compared to vertical dipping. For a 250-mm-long model, the difference in thickness between the top and bottom of the membrane was 0.42±0.069mm and 0.09±0.077mm for vertical and horizontal dippings, respectively. Mold diameter also affected the thickness of the membrane, with membrane thickness increasing as mold diameter decreased. Thickness data comparing locations at approximately the same height of the mold but with different diameters showed thicknesses of 2.54±0.198mm and 1.95±0.140mm for 7.85mm and 15.20mm diameters, respectively. Moreover, the differences in thickness between these locations were 0.60±0.128mm and 0.58±0.231mm for vertical and horizontal dippings, respectively; thus, membrane thickness variations occurred with mold diameter irrespective of the dipping setup. Depending on the prescribed tolerance for membrane thickness, the vertical dipping setup may be recommended for use because (1) it was easier to use since only the mold was immersed in the coating solution and no special protection of the dipping mechanism was required and (2) it produced fewer defects in the coatings since the solution always dripped from downfacing surfaces of the mold. Using this dip-spin coating procedure, patient-specific cardiovascular membranes can be manufactured and used in the development of medical devices, research requiring accurate anatomical models, and education and training.
    keyword(s): Coating processes , Coatings , Manufacturing , Particle spin , Silicones , Thickness , Vessels , Aorta , Bifurcation , Cardiovascular system , Computers , Membranes , Mechanisms , Viscosity AND Product quality ,
    • Download: (1.537Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Patient-Specific Compliant Vessel Manufacturing Using Dip-Spin Coating of Rapid Prototyped Molds

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/138665
    Collections
    • Journal of Manufacturing Science and Engineering

    Show full item record

    contributor authorKarina Arcaute
    contributor authorRyan B. Wicker
    date accessioned2017-05-09T00:29:20Z
    date available2017-05-09T00:29:20Z
    date copyrightOctober, 2008
    date issued2008
    identifier issn1087-1357
    identifier otherJMSEFK-28030#051008_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/138665
    description abstractA procedure for manufacturing cardiovascular system models using patient-specific data, rapid prototyping, and a multistep dip-spin coating process is presented here. Improvements to a previously developed process permitted the fabrication of flexible complex vascular replicas. The primary improvement included the development of a two-axis rotation mechanism that enabled a pseudorandom rotation of the coated mold in space, providing uniform coats. Other improvements included the use of a low viscosity (1500–2000cP) silicone solution that allowed for complete coverage of the mold, and developing a procedure for fixing defects. The dip-spin coating procedure was shown to be effective for the manufacture of compliant cardiovascular membranes, such as an arterial bypass graft with an internal flow passage and an abdominal aorta with nonuniform radial geometry, tapered diameters, bifurcations, and small branches. Results from a design of experiments comparing two dipping setups demonstrated that horizontally dipping the model produced coatings with more uniform thicknesses along the length of the model when compared to vertical dipping. For a 250-mm-long model, the difference in thickness between the top and bottom of the membrane was 0.42±0.069mm and 0.09±0.077mm for vertical and horizontal dippings, respectively. Mold diameter also affected the thickness of the membrane, with membrane thickness increasing as mold diameter decreased. Thickness data comparing locations at approximately the same height of the mold but with different diameters showed thicknesses of 2.54±0.198mm and 1.95±0.140mm for 7.85mm and 15.20mm diameters, respectively. Moreover, the differences in thickness between these locations were 0.60±0.128mm and 0.58±0.231mm for vertical and horizontal dippings, respectively; thus, membrane thickness variations occurred with mold diameter irrespective of the dipping setup. Depending on the prescribed tolerance for membrane thickness, the vertical dipping setup may be recommended for use because (1) it was easier to use since only the mold was immersed in the coating solution and no special protection of the dipping mechanism was required and (2) it produced fewer defects in the coatings since the solution always dripped from downfacing surfaces of the mold. Using this dip-spin coating procedure, patient-specific cardiovascular membranes can be manufactured and used in the development of medical devices, research requiring accurate anatomical models, and education and training.
    publisherThe American Society of Mechanical Engineers (ASME)
    titlePatient-Specific Compliant Vessel Manufacturing Using Dip-Spin Coating of Rapid Prototyped Molds
    typeJournal Paper
    journal volume130
    journal issue5
    journal titleJournal of Manufacturing Science and Engineering
    identifier doi10.1115/1.2898839
    journal fristpage51008
    identifier eissn1528-8935
    keywordsCoating processes
    keywordsCoatings
    keywordsManufacturing
    keywordsParticle spin
    keywordsSilicones
    keywordsThickness
    keywordsVessels
    keywordsAorta
    keywordsBifurcation
    keywordsCardiovascular system
    keywordsComputers
    keywordsMembranes
    keywordsMechanisms
    keywordsViscosity AND Product quality
    treeJournal of Manufacturing Science and Engineering:;2008:;volume( 130 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian