    Development of a Testing Methodology to Quantify Bone Load Transfer Patterns for Multiple Stemmed Implants in a Single Bone With an Application in the Distal Ulna

    Source: Journal of Biomechanical Engineering:;2008:;volume( 130 ):;issue: 002::page 24502
    Author:
    Rebecca L. Austman
    ,
    Graham J. King
    ,
    Karen D. Gordon
    ,
    Cynthia E. Dunning
    ,
    Cheryl E. Quenneville
    ,
    Brendon J. Beaton
    DOI: 10.1115/1.2899572
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Optimal parameters for many orthopaedic implants, such as stem length and material, are unknown. Geometry and mechanical properties of bone can vary greatly amongst cadaveric specimens, requiring a large number of specimens to test design variations. This study aimed to develop an experimental methodology to measure bone strains as a function of multiple implant stem designs in a single specimen, and evaluate its efficacy in the distal ulna. Eight fresh-frozen cadaveric ulnae were each instrumented with 12 uniaxial strain gauges on the medial and lateral surfaces of the bone. The proximal portion of each ulna was cemented in a custom-designed jig that allowed a medially directed force to be applied to the distal articular surface. An implant with a finely threaded stem was cemented into the canal by an experienced upper extremity orthopaedic surgeon. Six loads (5–30N) were applied sequentially to the lateral surface of the prosthetic head using a materials testing machine. Testing was repeated after breaking the stem-cement bond, and after removing and reinserting the stem several times into the threaded cement mantle. Near the end of the testing period, the initial stem was reinserted and data were collected to determine if there was any change in bone properties or testing setup over time. Finally, a smooth stem was inserted for comparison to the threaded stem. Strain varied linearly with load (R2≥0.99) for all testing scenarios. Bending strains were not affected by breaking the stem-cement bond (P=0.7), testing durations up to 18h(P=0.7), nor the presence of threads when compared to a smooth stem (P>0.4). Furthermore, for all gauges, there was no interaction between the effect of the threads and level of applied load (P>0.1). This methodology should prove to be useful to compare stem designs of varying lengths and materials in the same bone, allowing for a direct comparison between implant designs for the ulna and other bones subjected primarily to bending loads. Furthermore, it will minimize the need for large numbers of specimens to test multiple implant designs. The ultimate goal of using this protocol is to optimize implant stem properties, such as length and material, with respect to load transfer.
    keyword(s): Stress , Cements (Adhesives) , Bone , Testing , Canals , Gages AND Design ,
    • Download: (450.5Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Development of a Testing Methodology to Quantify Bone Load Transfer Patterns for Multiple Stemmed Implants in a Single Bone With an Application in the Distal Ulna

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/137503
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorRebecca L. Austman
    contributor authorGraham J. King
    contributor authorKaren D. Gordon
    contributor authorCynthia E. Dunning
    contributor authorCheryl E. Quenneville
    contributor authorBrendon J. Beaton
    date accessioned2017-05-09T00:27:04Z
    date available2017-05-09T00:27:04Z
    date copyrightApril, 2008
    date issued2008
    identifier issn0148-0731
    identifier otherJBENDY-26799#024502_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/137503
    description abstractOptimal parameters for many orthopaedic implants, such as stem length and material, are unknown. Geometry and mechanical properties of bone can vary greatly amongst cadaveric specimens, requiring a large number of specimens to test design variations. This study aimed to develop an experimental methodology to measure bone strains as a function of multiple implant stem designs in a single specimen, and evaluate its efficacy in the distal ulna. Eight fresh-frozen cadaveric ulnae were each instrumented with 12 uniaxial strain gauges on the medial and lateral surfaces of the bone. The proximal portion of each ulna was cemented in a custom-designed jig that allowed a medially directed force to be applied to the distal articular surface. An implant with a finely threaded stem was cemented into the canal by an experienced upper extremity orthopaedic surgeon. Six loads (5–30N) were applied sequentially to the lateral surface of the prosthetic head using a materials testing machine. Testing was repeated after breaking the stem-cement bond, and after removing and reinserting the stem several times into the threaded cement mantle. Near the end of the testing period, the initial stem was reinserted and data were collected to determine if there was any change in bone properties or testing setup over time. Finally, a smooth stem was inserted for comparison to the threaded stem. Strain varied linearly with load (R2≥0.99) for all testing scenarios. Bending strains were not affected by breaking the stem-cement bond (P=0.7), testing durations up to 18h(P=0.7), nor the presence of threads when compared to a smooth stem (P>0.4). Furthermore, for all gauges, there was no interaction between the effect of the threads and level of applied load (P>0.1). This methodology should prove to be useful to compare stem designs of varying lengths and materials in the same bone, allowing for a direct comparison between implant designs for the ulna and other bones subjected primarily to bending loads. Furthermore, it will minimize the need for large numbers of specimens to test multiple implant designs. The ultimate goal of using this protocol is to optimize implant stem properties, such as length and material, with respect to load transfer.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDevelopment of a Testing Methodology to Quantify Bone Load Transfer Patterns for Multiple Stemmed Implants in a Single Bone With an Application in the Distal Ulna
    typeJournal Paper
    journal volume130
    journal issue2
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.2899572
    journal fristpage24502
    identifier eissn1528-8951
    keywordsStress
    keywordsCements (Adhesives)
    keywordsBone
    keywordsTesting
    keywordsCanals
    keywordsGages AND Design
    treeJournal of Biomechanical Engineering:;2008:;volume( 130 ):;issue: 002
    contenttypeFulltext