    A Theoretical and Experimental Investigation of Lateral Deformations in a Unilateral External Fixator

    Source: Journal of Medical Devices:;2007:;volume( 001 ):;issue: 002::page 165
    Author:
    Kerem Ün
    ,
    İbrahim D. Akçalı
    ,
    Mahir Gülşen
    DOI: 10.1115/1.2735972
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The objective of this work is to set up, validate, and analyze a theoretical model of an external fixator for its deformation characteristics in order to draw reliable conclusions relevant to the design and effective clinical implementation of such medical devices. External fixators are mechanical devices widely used in the treatment of fractured bones and correction of limb deformities. Lateral deformation at the fracture site is known to delay bone healing, and investigation of lateral deformation characteristics of such devices experiencing forces acting perpendicular to the bone axis is important from the standpoint of their design as well as their clinical effectiveness. A mathematical model of a three-dimensional (3D) unilateral fixator with multipin fragment attachments has been developed using Castigliano’s method. The relative lateral deformations of the fragment ends at the fracture site induced by loads applied perpendicular to bone axes are calculated with the model. The model has been subjected to experimental verification for a uniplanar unilateral external fixator under comparable conditions with the theory. It has been found out that the effects of fixator size, shape, and geometry on the level of relative lateral displacement of the fracture site are similar in both the theoretical and experimental models. Stiffness is a maximum if the force is applied in the same plane as the proximal pin plane. Placing the distal pin group at a 90deg position relative to the proximal pin plane has been observed to increase the stiffness about 10%. In loading directions perpendicular to proximal the pin plane, stiffness is minimum. The angle difference between the load direction and the resulting displacement direction follows a sinusoidal pattern with an amplitude of 10deg for loading angles in the 0–180deg range. Selecting the distance of proximal pins to the fracture site smaller than the distance of distal pins to the fracture site has been found to decrease relative lateral deformation. The model and the experiment have simultaneously demonstrated that lower values of effective pin lengths and higher values of pin connector lengths lead to higher stiffness. Increasing the number of pins also contributes to the higher values of fixator stiffness.
    keyword(s): Force , Deformation , Pins (Engineering) , Bone , Fracture (Process) , Displacement , Stiffness AND Theoretical analysis ,
    • Download: (210.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Theoretical and Experimental Investigation of Lateral Deformations in a Unilateral External Fixator

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/136586
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorKerem Ün
    contributor authorİbrahim D. Akçalı
    contributor authorMahir Gülşen
    date accessioned2017-05-09T00:25:18Z
    date available2017-05-09T00:25:18Z
    date copyrightJune, 2007
    date issued2007
    identifier issn1932-6181
    identifier otherJMDOA4-27984#165_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/136586
    description abstractThe objective of this work is to set up, validate, and analyze a theoretical model of an external fixator for its deformation characteristics in order to draw reliable conclusions relevant to the design and effective clinical implementation of such medical devices. External fixators are mechanical devices widely used in the treatment of fractured bones and correction of limb deformities. Lateral deformation at the fracture site is known to delay bone healing, and investigation of lateral deformation characteristics of such devices experiencing forces acting perpendicular to the bone axis is important from the standpoint of their design as well as their clinical effectiveness. A mathematical model of a three-dimensional (3D) unilateral fixator with multipin fragment attachments has been developed using Castigliano’s method. The relative lateral deformations of the fragment ends at the fracture site induced by loads applied perpendicular to bone axes are calculated with the model. The model has been subjected to experimental verification for a uniplanar unilateral external fixator under comparable conditions with the theory. It has been found out that the effects of fixator size, shape, and geometry on the level of relative lateral displacement of the fracture site are similar in both the theoretical and experimental models. Stiffness is a maximum if the force is applied in the same plane as the proximal pin plane. Placing the distal pin group at a 90deg position relative to the proximal pin plane has been observed to increase the stiffness about 10%. In loading directions perpendicular to proximal the pin plane, stiffness is minimum. The angle difference between the load direction and the resulting displacement direction follows a sinusoidal pattern with an amplitude of 10deg for loading angles in the 0–180deg range. Selecting the distance of proximal pins to the fracture site smaller than the distance of distal pins to the fracture site has been found to decrease relative lateral deformation. The model and the experiment have simultaneously demonstrated that lower values of effective pin lengths and higher values of pin connector lengths lead to higher stiffness. Increasing the number of pins also contributes to the higher values of fixator stiffness.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Theoretical and Experimental Investigation of Lateral Deformations in a Unilateral External Fixator
    typeJournal Paper
    journal volume1
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.2735972
    journal fristpage165
    journal lastpage172
    identifier eissn1932-619X
    keywordsForce
    keywordsDeformation
    keywordsPins (Engineering)
    keywordsBone
    keywordsFracture (Process)
    keywordsDisplacement
    keywordsStiffness AND Theoretical analysis
    treeJournal of Medical Devices:;2007:;volume( 001 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian