    Wear in the Prosthetic Shoulder: Association With Design Parameters

    Source: Journal of Biomechanical Engineering:;2007:;volume( 129 ):;issue: 002::page 223
    Author:
    Andrew R. Hopkins
    ,
    Ulrich N. Hansen
    ,
    Andrew A. Amis
    ,
    Lucy Knight
    ,
    Ofer Levy
    ,
    Stephen A. Copeland
    ,
    Mark Taylor
    DOI: 10.1115/1.2486060
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Total replacement of the glenohumeral joint provides an effective means for treating a variety of pathologies of the shoulder. However, several studies indicate that the procedure has not yet been entirely optimized. Loosening of the glenoid component remains the most likely cause of implant failure, and generally this is believed to stem from either mechanical failure of the fixation in response to high tensile stresses, or through osteolysis of the surrounding bone stock in response to particulate wear debris. Many computational studies have considered the potential for the former, although only few have attempted to tackle the latter. Using finite-element analysis an investigation, taking into account contact pressures as well as glenohumeral kinematics, has thus been conducted, to assess the potential for polyethylene wear within the artificial shoulder. The relationships between three different aspects of glenohumeral design and the potential for wear have been considered, these being conformity, polyethylene thickness, and fixation type. The results of the current study indicate that the use of conforming designs are likely to produce slightly elevated amounts of wear debris particles when compared with less conforming joints, but that the latter would be more likely to cause material failure of the polyethylene. The volume of wear debris predicted was highly influenced by the rate of loading, however qualitatively it was found that wear predictions were not influenced by the use of different polyethylene thicknesses nor fixation type while the depth of wearing was. With the thinnest polyethylene designs (2mm) the maximum depth of the wear scar was seen to be upwards of 20% higher with a metal-backed fixation as opposed to a cemented design. In all-polyethylene designs peak polymethyl methacrylate tensile stresses were seen to reduce with increasing polyethylene thickness. Irrespective of the rate of loading of the shoulder joint, the current study indicates that it is possible to optimize glenoid component design against abrasive wear through the use of high conformity designs, possessing a polyethylene thickness of at least 6mm.
    keyword(s): Wear , Design , Thickness , Metals AND Artificial limbs ,
    • Download: (854.9Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Wear in the Prosthetic Shoulder: Association With Design Parameters

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/135284
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorAndrew R. Hopkins
    contributor authorUlrich N. Hansen
    contributor authorAndrew A. Amis
    contributor authorLucy Knight
    contributor authorOfer Levy
    contributor authorStephen A. Copeland
    contributor authorMark Taylor
    date accessioned2017-05-09T00:22:51Z
    date available2017-05-09T00:22:51Z
    date copyrightApril, 2007
    date issued2007
    identifier issn0148-0731
    identifier otherJBENDY-26680#223_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/135284
    description abstractTotal replacement of the glenohumeral joint provides an effective means for treating a variety of pathologies of the shoulder. However, several studies indicate that the procedure has not yet been entirely optimized. Loosening of the glenoid component remains the most likely cause of implant failure, and generally this is believed to stem from either mechanical failure of the fixation in response to high tensile stresses, or through osteolysis of the surrounding bone stock in response to particulate wear debris. Many computational studies have considered the potential for the former, although only few have attempted to tackle the latter. Using finite-element analysis an investigation, taking into account contact pressures as well as glenohumeral kinematics, has thus been conducted, to assess the potential for polyethylene wear within the artificial shoulder. The relationships between three different aspects of glenohumeral design and the potential for wear have been considered, these being conformity, polyethylene thickness, and fixation type. The results of the current study indicate that the use of conforming designs are likely to produce slightly elevated amounts of wear debris particles when compared with less conforming joints, but that the latter would be more likely to cause material failure of the polyethylene. The volume of wear debris predicted was highly influenced by the rate of loading, however qualitatively it was found that wear predictions were not influenced by the use of different polyethylene thicknesses nor fixation type while the depth of wearing was. With the thinnest polyethylene designs (2mm) the maximum depth of the wear scar was seen to be upwards of 20% higher with a metal-backed fixation as opposed to a cemented design. In all-polyethylene designs peak polymethyl methacrylate tensile stresses were seen to reduce with increasing polyethylene thickness. Irrespective of the rate of loading of the shoulder joint, the current study indicates that it is possible to optimize glenoid component design against abrasive wear through the use of high conformity designs, possessing a polyethylene thickness of at least 6mm.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleWear in the Prosthetic Shoulder: Association With Design Parameters
    typeJournal Paper
    journal volume129
    journal issue2
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.2486060
    journal fristpage223
    journal lastpage230
    identifier eissn1528-8951
    keywordsWear
    keywordsDesign
    keywordsThickness
    keywordsMetals AND Artificial limbs
    treeJournal of Biomechanical Engineering:;2007:;volume( 129 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian