YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Cyclic Mechanical Compression Increases Mineralization of Cell-Seeded Polymer Scaffolds In Vivo

    Source: Journal of Biomechanical Engineering:;2007:;volume( 129 ):;issue: 004::page 531
    Author:
    Angel O. Duty
    ,
    Robert E. Guldberg
    ,
    Megan E. Oest
    DOI: 10.1115/1.2746375
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Despite considerable documentation of the ability of normal bone to adapt to its mechanical environment, very little is known about the response of bone grafts or their substitutes to mechanical loading even though many bone defects are located in load-bearing sites. The goal of this research was to quantify the effects of controlled in vivo mechanical stimulation on the mineralization of a tissue-engineered bone replacement and identify the tissue level stresses and strains associated with the applied loading. A novel subcutaneous implant system was designed capable of intermittent cyclic compression of tissue-engineered constructs in vivo. Mesenchymal stem cell-seeded polymeric scaffolds with 8 weeks of in vitro preculture were placed within the loading system and implanted subcutaneously in male Fisher rats. Constructs were subjected to 2 weeks of loading (3 treatments per week for 30min each, 13.3N at 1Hz) and harvested after 6 weeks of in vivo growth for histological examination and quantification of mineral content. Mineralization significantly increased by approximately threefold in the loaded constructs. The finite element method was used to predict tissue level stresses and strains within the construct resulting from the applied in vivo load. The largest principal strains in the polymer were distributed about a modal value of −0.24% with strains in the interstitial space being about five times greater. Von Mises stresses in the polymer were distributed about a modal value of 1.6MPa, while stresses in the interstitial tissue were about three orders of magnitude smaller. This research demonstrates the ability of controlled in vivo mechanical stimulation to enhance mineralized matrix production on a polymeric scaffold seeded with osteogenic cells and suggests that interactions with the local mechanical environment should be considered in the design of constructs for functional bone repair.
    keyword(s): Stress , Biological tissues , Bone , Finite element analysis , Polymers , Compression , Design AND Maintenance ,
    • Download: (741.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Cyclic Mechanical Compression Increases Mineralization of Cell-Seeded Polymer Scaffolds In Vivo

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/135235
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorAngel O. Duty
    contributor authorRobert E. Guldberg
    contributor authorMegan E. Oest
    date accessioned2017-05-09T00:22:45Z
    date available2017-05-09T00:22:45Z
    date copyrightAugust, 2007
    date issued2007
    identifier issn0148-0731
    identifier otherJBENDY-26731#531_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/135235
    description abstractDespite considerable documentation of the ability of normal bone to adapt to its mechanical environment, very little is known about the response of bone grafts or their substitutes to mechanical loading even though many bone defects are located in load-bearing sites. The goal of this research was to quantify the effects of controlled in vivo mechanical stimulation on the mineralization of a tissue-engineered bone replacement and identify the tissue level stresses and strains associated with the applied loading. A novel subcutaneous implant system was designed capable of intermittent cyclic compression of tissue-engineered constructs in vivo. Mesenchymal stem cell-seeded polymeric scaffolds with 8 weeks of in vitro preculture were placed within the loading system and implanted subcutaneously in male Fisher rats. Constructs were subjected to 2 weeks of loading (3 treatments per week for 30min each, 13.3N at 1Hz) and harvested after 6 weeks of in vivo growth for histological examination and quantification of mineral content. Mineralization significantly increased by approximately threefold in the loaded constructs. The finite element method was used to predict tissue level stresses and strains within the construct resulting from the applied in vivo load. The largest principal strains in the polymer were distributed about a modal value of −0.24% with strains in the interstitial space being about five times greater. Von Mises stresses in the polymer were distributed about a modal value of 1.6MPa, while stresses in the interstitial tissue were about three orders of magnitude smaller. This research demonstrates the ability of controlled in vivo mechanical stimulation to enhance mineralized matrix production on a polymeric scaffold seeded with osteogenic cells and suggests that interactions with the local mechanical environment should be considered in the design of constructs for functional bone repair.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleCyclic Mechanical Compression Increases Mineralization of Cell-Seeded Polymer Scaffolds In Vivo
    typeJournal Paper
    journal volume129
    journal issue4
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.2746375
    journal fristpage531
    journal lastpage539
    identifier eissn1528-8951
    keywordsStress
    keywordsBiological tissues
    keywordsBone
    keywordsFinite element analysis
    keywordsPolymers
    keywordsCompression
    keywordsDesign AND Maintenance
    treeJournal of Biomechanical Engineering:;2007:;volume( 129 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian