    Clamp Load Loss due to Fastener Elongation Beyond its Elastic Limit

    Source: Journal of Pressure Vessel Technology:;2006:;volume( 128 ):;issue: 003::page 379
    Author:
    Sayed A. Nassar
    ,
    Payam H. Matin
    DOI: 10.1115/1.2217971
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The amount of clamp load due to an externally applied separating force is determined for a boiled assembly in which the fastener is elongated past its proportional limit, while the clamped joint remained within its elastic range. After the initial tightening of the fastener, the joint is subsequently subjected to a tensile separating force, which further increases the fastener tensile stress into the nonlinear range. Such separating force will simultaneously reduce the clamping force in the bolted joint. Upon the removal of the separating service load, the bolted joint system reaches a new equilibrium point between the fastener tension and the joint clamping force. At the new equilibrium point, the fastener tension is reduced from its value at initial assembly, due to the plastic elongation of the fastener. The reduction in fastener tension translates into a partial—yet permanent—loss of the clamping load that may lead to joint leakage, loosening, or fatigue failure. A nonlinear model is established in order to describe the fastener behavior past the proportional limit of its material, and to determine the clamp load loss due to the permanent set in the fastener after the separating force has been removed. Two fastener materials with significantly different rates of strain hardening are used for modeling the behavior of the bolted joint system. The effect of three nondimensional variables on the amount of clamp load loss is investigated. The first variable is the stiffness ratio of the joint and the fastener. The second is the ratio of initial fastener tension to the fastener elastic limit, and the third variable is the ratio of the separating force to the force that causes joint separation to start. Analytical results are presented for a range of stiffness ratios that simulates both soft and hard joint applications. Experimental verification of the analytical results is presented.
    keyword(s): Force , Stress , Fasteners , Clamps (Tools) , Elongation , Tension AND Stiffness ,
    • Download: (1.203Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Clamp Load Loss due to Fastener Elongation Beyond its Elastic Limit

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/134502
    Collections
    • Journal of Pressure Vessel Technology

    Show full item record

    contributor authorSayed A. Nassar
    contributor authorPayam H. Matin
    date accessioned2017-05-09T00:21:21Z
    date available2017-05-09T00:21:21Z
    date copyrightAugust, 2006
    date issued2006
    identifier issn0094-9930
    identifier otherJPVTAS-28470#379_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/134502
    description abstractThe amount of clamp load due to an externally applied separating force is determined for a boiled assembly in which the fastener is elongated past its proportional limit, while the clamped joint remained within its elastic range. After the initial tightening of the fastener, the joint is subsequently subjected to a tensile separating force, which further increases the fastener tensile stress into the nonlinear range. Such separating force will simultaneously reduce the clamping force in the bolted joint. Upon the removal of the separating service load, the bolted joint system reaches a new equilibrium point between the fastener tension and the joint clamping force. At the new equilibrium point, the fastener tension is reduced from its value at initial assembly, due to the plastic elongation of the fastener. The reduction in fastener tension translates into a partial—yet permanent—loss of the clamping load that may lead to joint leakage, loosening, or fatigue failure. A nonlinear model is established in order to describe the fastener behavior past the proportional limit of its material, and to determine the clamp load loss due to the permanent set in the fastener after the separating force has been removed. Two fastener materials with significantly different rates of strain hardening are used for modeling the behavior of the bolted joint system. The effect of three nondimensional variables on the amount of clamp load loss is investigated. The first variable is the stiffness ratio of the joint and the fastener. The second is the ratio of initial fastener tension to the fastener elastic limit, and the third variable is the ratio of the separating force to the force that causes joint separation to start. Analytical results are presented for a range of stiffness ratios that simulates both soft and hard joint applications. Experimental verification of the analytical results is presented.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleClamp Load Loss due to Fastener Elongation Beyond its Elastic Limit
    typeJournal Paper
    journal volume128
    journal issue3
    journal titleJournal of Pressure Vessel Technology
    identifier doi10.1115/1.2217971
    journal fristpage379
    journal lastpage387
    identifier eissn1528-8978
    keywordsForce
    keywordsStress
    keywordsFasteners
    keywordsClamps (Tools)
    keywordsElongation
    keywordsTension AND Stiffness
    treeJournal of Pressure Vessel Technology:;2006:;volume( 128 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian