    Analytic Wavelet-Based Ultrasonic Pulse Differentiation for Injection Mold Cavity Pressure Measurement

    Source: Journal of Manufacturing Science and Engineering:;2006:;volume( 128 ):;issue: 001::page 370
    Author:
    Li Zhang
    ,
    Charles B. Theurer
    ,
    Robert X. Gao
    ,
    David O. Kazmer
    DOI: 10.1115/1.2123048
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A new signal-processing technique based on analytic wavelet transform has been developed for detecting and differentiating temporally overlapped ultrasonic pulse trains that carry spatially distributed pressure information across an injection mold cavity. Compared to conventional wavelets that have a constant relative bandwidth at all the scales, the analytic wavelets investigated in this paper feature variable relative bandwidth, making it possible to simultaneously match the frequency characteristics of the ultrasonic pulse trains transmitted from the mold-embedded pressure sensors. As a result, more accurate detection and differentiation of the temporal and spectral information embedded within the ultrasonic pulse trains could be achieved. Theoretical framework for the analytic wavelet transform was established, and a multichannel ultrasonic pulse detector based on the complex Morlet wavelet was designed and experimentally investigated. The results have confirmed the effectiveness of the new signal-processing technique for on-line pressure sensing for injection molding process monitoring.
    keyword(s): Sensors , Cavities , Trains , Wavelets , Wavelet transforms AND Signals ,
    • Download: (251.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Analytic Wavelet-Based Ultrasonic Pulse Differentiation for Injection Mold Cavity Pressure Measurement

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/134192
    Collections
    • Journal of Manufacturing Science and Engineering

    Show full item record

    contributor authorLi Zhang
    contributor authorCharles B. Theurer
    contributor authorRobert X. Gao
    contributor authorDavid O. Kazmer
    date accessioned2017-05-09T00:20:46Z
    date available2017-05-09T00:20:46Z
    date copyrightFebruary, 2006
    date issued2006
    identifier issn1087-1357
    identifier otherJMSEFK-27914#370_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/134192
    description abstractA new signal-processing technique based on analytic wavelet transform has been developed for detecting and differentiating temporally overlapped ultrasonic pulse trains that carry spatially distributed pressure information across an injection mold cavity. Compared to conventional wavelets that have a constant relative bandwidth at all the scales, the analytic wavelets investigated in this paper feature variable relative bandwidth, making it possible to simultaneously match the frequency characteristics of the ultrasonic pulse trains transmitted from the mold-embedded pressure sensors. As a result, more accurate detection and differentiation of the temporal and spectral information embedded within the ultrasonic pulse trains could be achieved. Theoretical framework for the analytic wavelet transform was established, and a multichannel ultrasonic pulse detector based on the complex Morlet wavelet was designed and experimentally investigated. The results have confirmed the effectiveness of the new signal-processing technique for on-line pressure sensing for injection molding process monitoring.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAnalytic Wavelet-Based Ultrasonic Pulse Differentiation for Injection Mold Cavity Pressure Measurement
    typeJournal Paper
    journal volume128
    journal issue1
    journal titleJournal of Manufacturing Science and Engineering
    identifier doi10.1115/1.2123048
    journal fristpage370
    journal lastpage374
    identifier eissn1528-8935
    keywordsSensors
    keywordsCavities
    keywordsTrains
    keywordsWavelets
    keywordsWavelet transforms AND Signals
    treeJournal of Manufacturing Science and Engineering:;2006:;volume( 128 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian