YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Fuel Cell Science and Technology
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Fuel Cell Science and Technology
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    To Achieve the Best Performance Through Optimization of Gas Delivery and Current Collection in Solid Oxide Fuel Cells

    Source: Journal of Fuel Cell Science and Technology:;2006:;volume( 003 ):;issue: 002::page 188
    Author:
    P. W. Li
    ,
    S. P. Chen
    ,
    M. K. Chyu
    DOI: 10.1115/1.2174068
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Aimed at improving the maximum available power density in a planar-type solid oxide fuel cell, an analytical model is proposed in this work to find the optimum size of a current collector that collects the current from a specific active area of the electrode-electrolyte layer. Distributed three-dimensional current collectors in gas delivery field are designated to allow a larger area of the electrode-electrolyte layer to be active for electrochemical reaction compared to conventional designs that gas channels are separated by current collectors. It has been found that the optimal operating temperature of a planar-type solid oxide fuel cell might be around 850°C, if the sizes of the distributed current collectors and their control areas are optimized. Decreasing the size of both the current collector and its control area is advantageous in achieving a higher power density. Studies also show that the optimal sizes of the current collector and the current collection area investigated at 850°C and zero concentration polarization are applicable to situations of different operating temperatures, and different concentration polarizations. The optimization results of the sizes of current collectors and their control areas are relatively sensitive to the contact resistance between the current collectors and the electrodes of the fuel cell. Results of great significance are provided in the analysis, which will help designers to account for the variation of contact resistance in optimization designing of a bipolar plate of fuel cells.
    keyword(s): Density , Optimization , Solid oxide fuel cells , Operating temperature , Fuel cells AND Electrodes ,
    • Download: (385.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      To Achieve the Best Performance Through Optimization of Gas Delivery and Current Collection in Solid Oxide Fuel Cells

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/134076
    Collections
    • Journal of Fuel Cell Science and Technology

    Show full item record

    contributor authorP. W. Li
    contributor authorS. P. Chen
    contributor authorM. K. Chyu
    date accessioned2017-05-09T00:20:35Z
    date available2017-05-09T00:20:35Z
    date copyrightMay, 2006
    date issued2006
    identifier issn2381-6872
    identifier otherJFCSAU-28925#188_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/134076
    description abstractAimed at improving the maximum available power density in a planar-type solid oxide fuel cell, an analytical model is proposed in this work to find the optimum size of a current collector that collects the current from a specific active area of the electrode-electrolyte layer. Distributed three-dimensional current collectors in gas delivery field are designated to allow a larger area of the electrode-electrolyte layer to be active for electrochemical reaction compared to conventional designs that gas channels are separated by current collectors. It has been found that the optimal operating temperature of a planar-type solid oxide fuel cell might be around 850°C, if the sizes of the distributed current collectors and their control areas are optimized. Decreasing the size of both the current collector and its control area is advantageous in achieving a higher power density. Studies also show that the optimal sizes of the current collector and the current collection area investigated at 850°C and zero concentration polarization are applicable to situations of different operating temperatures, and different concentration polarizations. The optimization results of the sizes of current collectors and their control areas are relatively sensitive to the contact resistance between the current collectors and the electrodes of the fuel cell. Results of great significance are provided in the analysis, which will help designers to account for the variation of contact resistance in optimization designing of a bipolar plate of fuel cells.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleTo Achieve the Best Performance Through Optimization of Gas Delivery and Current Collection in Solid Oxide Fuel Cells
    typeJournal Paper
    journal volume3
    journal issue2
    journal titleJournal of Fuel Cell Science and Technology
    identifier doi10.1115/1.2174068
    journal fristpage188
    journal lastpage194
    identifier eissn2381-6910
    keywordsDensity
    keywordsOptimization
    keywordsSolid oxide fuel cells
    keywordsOperating temperature
    keywordsFuel cells AND Electrodes
    treeJournal of Fuel Cell Science and Technology:;2006:;volume( 003 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian