    Sensitivity Analysis of Entrance Design Parameters of a Backward-Inclined Centrifugal Fan Using DOE Method and CFD Calculations

    Source: Journal of Fluids Engineering:;2006:;volume( 128 ):;issue: 003::page 446
    Author:
    A. Behzadmehr
    ,
    Y. Mercadier
    ,
    N. Galanis
    DOI: 10.1115/1.2173293
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Centrifugal fans with an electric motor included in the hub are commonly used in HVAC (heating, ventilation, and air conditioning) systems. A design of experiments (DOE) has been performed to study the effect of the entrance conditions of a backward-inclined centrifugal fan on its efficiency. The parameters involved are the base radius of the motor hub, the radius of the fan entry section, the deceleration factor throughout the entry zone (from the entry of the fan to the entry of the blade), and the solidity factor. Numerical simulation coupled with the DOE has been used for the sensitivity analysis of the entrance parameters. Initially, a complete factorial plan (24) was performed to screen the most influent parameters and interactions. This has shown that the motor’s cap radius, as well as its interactions with other parameters, is not significant. A second DOE, using composite central design (CCD which has a second order of accuracy) has then been performed on the remaining parameters (radius of the fan entry section, deceleration factor, and the solidity factor). The effects of these parameters and their interactions on the fan efficiency are now presented. A linear regression with three parameters has been performed to establish the efficiency distribution map. The methodology employed is validated by comparing the predicted results from the DOE and those from the numerical simulation of the corresponding fan.
    keyword(s): Design , Sensitivity analysis , Computer simulation , Blades , Computational fluid dynamics AND Geometry ,
    • Download: (330.9Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Sensitivity Analysis of Entrance Design Parameters of a Backward-Inclined Centrifugal Fan Using DOE Method and CFD Calculations

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/133933
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorA. Behzadmehr
    contributor authorY. Mercadier
    contributor authorN. Galanis
    date accessioned2017-05-09T00:20:20Z
    date available2017-05-09T00:20:20Z
    date copyrightMay, 2006
    date issued2006
    identifier issn0098-2202
    identifier otherJFEGA4-27217#446_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/133933
    description abstractCentrifugal fans with an electric motor included in the hub are commonly used in HVAC (heating, ventilation, and air conditioning) systems. A design of experiments (DOE) has been performed to study the effect of the entrance conditions of a backward-inclined centrifugal fan on its efficiency. The parameters involved are the base radius of the motor hub, the radius of the fan entry section, the deceleration factor throughout the entry zone (from the entry of the fan to the entry of the blade), and the solidity factor. Numerical simulation coupled with the DOE has been used for the sensitivity analysis of the entrance parameters. Initially, a complete factorial plan (24) was performed to screen the most influent parameters and interactions. This has shown that the motor’s cap radius, as well as its interactions with other parameters, is not significant. A second DOE, using composite central design (CCD which has a second order of accuracy) has then been performed on the remaining parameters (radius of the fan entry section, deceleration factor, and the solidity factor). The effects of these parameters and their interactions on the fan efficiency are now presented. A linear regression with three parameters has been performed to establish the efficiency distribution map. The methodology employed is validated by comparing the predicted results from the DOE and those from the numerical simulation of the corresponding fan.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleSensitivity Analysis of Entrance Design Parameters of a Backward-Inclined Centrifugal Fan Using DOE Method and CFD Calculations
    typeJournal Paper
    journal volume128
    journal issue3
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.2173293
    journal fristpage446
    journal lastpage453
    identifier eissn1528-901X
    keywordsDesign
    keywordsSensitivity analysis
    keywordsComputer simulation
    keywordsBlades
    keywordsComputational fluid dynamics AND Geometry
    treeJournal of Fluids Engineering:;2006:;volume( 128 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian