    Cooling the Tip of a Turbine Blade Using Pressure Side Holes—Part I: Adiabatic Effectiveness Measurements

    Source: Journal of Turbomachinery:;2005:;volume( 127 ):;issue: 002::page 270
    Author:
    J. R. Christophel
    ,
    F. J. Cunha
    ,
    K. A. Thole
    DOI: 10.1115/1.1812320
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Durability of turbine blade tips has been and continues to be challenging, particularly since increasing turbine inlet temperatures is the driver for improving turbine engine performance. As a result, cooling methods along the blade tip are crucial. Film-cooling is one typically used cooling method whereby coolant is supplied through holes placed along the pressure side of a blade. The subject of this paper is to evaluate the adiabatic effectiveness levels that occur on the blade tip through blowing coolant from holes placed near the tip of a blade along the pressure side. A range of blowing ratios was studied whereby coolant was injected from holes placed along the pressure side tip of a large-scale blade model. Also present were dirt purge holes on the blade tip, which is part of a commonly used blade design to expel any large particles present in the coolant stream. Experiments were conducted in a linear cascade with a scaled-up turbine blade whereby the Reynolds number of the engine was matched. This paper, which is Part 1 of a two part series, compares adiabatic effectiveness levels measured along a blade tip, while Part 2 combines measured heat transfer coefficients with the adiabatic effectiveness levels to assess the overall cooling benefit of pressure side blowing near a blade tip. The results show much better cooling can be achieved for a small tip gap compared with a large tip gap with different flow phenomena occurring for each tip gap setting.
    keyword(s): Pressure , Flow (Dynamics) , Cooling , Coolants , Blades , Turbine blades , Temperature AND Measurement ,
    • Download: (312.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Cooling the Tip of a Turbine Blade Using Pressure Side Holes—Part I: Adiabatic Effectiveness Measurements

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/132815
    Collections
    • Journal of Turbomachinery

    Show full item record

    contributor authorJ. R. Christophel
    contributor authorF. J. Cunha
    contributor authorK. A. Thole
    date accessioned2017-05-09T00:18:12Z
    date available2017-05-09T00:18:12Z
    date copyrightApril, 2005
    date issued2005
    identifier issn0889-504X
    identifier otherJOTUEI-28719#270_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/132815
    description abstractDurability of turbine blade tips has been and continues to be challenging, particularly since increasing turbine inlet temperatures is the driver for improving turbine engine performance. As a result, cooling methods along the blade tip are crucial. Film-cooling is one typically used cooling method whereby coolant is supplied through holes placed along the pressure side of a blade. The subject of this paper is to evaluate the adiabatic effectiveness levels that occur on the blade tip through blowing coolant from holes placed near the tip of a blade along the pressure side. A range of blowing ratios was studied whereby coolant was injected from holes placed along the pressure side tip of a large-scale blade model. Also present were dirt purge holes on the blade tip, which is part of a commonly used blade design to expel any large particles present in the coolant stream. Experiments were conducted in a linear cascade with a scaled-up turbine blade whereby the Reynolds number of the engine was matched. This paper, which is Part 1 of a two part series, compares adiabatic effectiveness levels measured along a blade tip, while Part 2 combines measured heat transfer coefficients with the adiabatic effectiveness levels to assess the overall cooling benefit of pressure side blowing near a blade tip. The results show much better cooling can be achieved for a small tip gap compared with a large tip gap with different flow phenomena occurring for each tip gap setting.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleCooling the Tip of a Turbine Blade Using Pressure Side Holes—Part I: Adiabatic Effectiveness Measurements
    typeJournal Paper
    journal volume127
    journal issue2
    journal titleJournal of Turbomachinery
    identifier doi10.1115/1.1812320
    journal fristpage270
    journal lastpage277
    identifier eissn1528-8900
    keywordsPressure
    keywordsFlow (Dynamics)
    keywordsCooling
    keywordsCoolants
    keywordsBlades
    keywordsTurbine blades
    keywordsTemperature AND Measurement
    treeJournal of Turbomachinery:;2005:;volume( 127 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian