    A Novel Ex Vivo Heart Model for the Assessment of Cardiac Pacing Systems

    Source: Journal of Biomechanical Engineering:;2005:;volume( 127 ):;issue: 006::page 894
    Author:
    Timothy G. Laske
    ,
    Paul A. Iaizzo
    ,
    Nicholas D. Skadsberg
    DOI: 10.1115/1.2049312
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Background: Advances in endocardial device design have been limited by the inability to visualize the device-tissue interface. The purpose of this study was to assess the validity of an isolated heart approach, which allows direct ex vivo intracardiac visualization, as a research tool for studying endocardial pacing systems. Method of approach: Endocardial pacing leads were implanted in the right atria and ventricles of intact swine (n=8) under fluoroscopic guidance. After collection of pacing and sensing performance parameters, the hearts were excised with the leads intact and reanimated on the isolated heart apparatus, and parameters again recorded. Results: Atrial ex vivo parameters significantly decreased compared with in vivo measurements: P-wave amplitudes by 39%, slew rates by 61%, and pacing impedances by 42% (p<0.05 for each). Similarly, several ventricular ex vivo parameters decreased: R-wave amplitudes by 39%, slew rates by 62%, and pacing impedances by 31%. In contrast, both atrial (4.4±2.8 vs 3.3±2.8V; p=ns) and ventricular thresholds increased (1.2±0.7 vs 0.6±0.1V; p<0.05 for all). Three distinct phenomena were observed at the lead-tissue interface. Normal implants (70%) demonstrated minimal tissue distortion and resulted in elevated impedance and threshold values. Three implants (13%) resulted in severe tissue distortion and/or tissue wrapping and were associated with highly elevated pacing parameters. Tissue coring occurred in four implants (17%) where the lead would spin freely in the tissue after overtorquing of the lead. Conclusions: The utility of the isolated heart approach was demonstrated as a tool for the design and assessment of the performance of endocardial pacing systems. Specifically, the ability to visualize device-heart interactions allows new insights into the impact of product design and clinical factors on lead performance and successful implantation.
    keyword(s): Measurement , Impedance (Electricity) , Waves , Biological tissues , Design , Visualization , Physiology , Electrodes , Statistical analysis , Blood , Particle spin AND Product design ,
    • Download: (528.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Novel Ex Vivo Heart Model for the Assessment of Cardiac Pacing Systems

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/131313
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorTimothy G. Laske
    contributor authorPaul A. Iaizzo
    contributor authorNicholas D. Skadsberg
    date accessioned2017-05-09T00:15:13Z
    date available2017-05-09T00:15:13Z
    date copyrightNovember, 2005
    date issued2005
    identifier issn0148-0731
    identifier otherJBENDY-26555#894_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/131313
    description abstractBackground: Advances in endocardial device design have been limited by the inability to visualize the device-tissue interface. The purpose of this study was to assess the validity of an isolated heart approach, which allows direct ex vivo intracardiac visualization, as a research tool for studying endocardial pacing systems. Method of approach: Endocardial pacing leads were implanted in the right atria and ventricles of intact swine (n=8) under fluoroscopic guidance. After collection of pacing and sensing performance parameters, the hearts were excised with the leads intact and reanimated on the isolated heart apparatus, and parameters again recorded. Results: Atrial ex vivo parameters significantly decreased compared with in vivo measurements: P-wave amplitudes by 39%, slew rates by 61%, and pacing impedances by 42% (p<0.05 for each). Similarly, several ventricular ex vivo parameters decreased: R-wave amplitudes by 39%, slew rates by 62%, and pacing impedances by 31%. In contrast, both atrial (4.4±2.8 vs 3.3±2.8V; p=ns) and ventricular thresholds increased (1.2±0.7 vs 0.6±0.1V; p<0.05 for all). Three distinct phenomena were observed at the lead-tissue interface. Normal implants (70%) demonstrated minimal tissue distortion and resulted in elevated impedance and threshold values. Three implants (13%) resulted in severe tissue distortion and/or tissue wrapping and were associated with highly elevated pacing parameters. Tissue coring occurred in four implants (17%) where the lead would spin freely in the tissue after overtorquing of the lead. Conclusions: The utility of the isolated heart approach was demonstrated as a tool for the design and assessment of the performance of endocardial pacing systems. Specifically, the ability to visualize device-heart interactions allows new insights into the impact of product design and clinical factors on lead performance and successful implantation.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Novel Ex Vivo Heart Model for the Assessment of Cardiac Pacing Systems
    typeJournal Paper
    journal volume127
    journal issue6
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.2049312
    journal fristpage894
    journal lastpage898
    identifier eissn1528-8951
    keywordsMeasurement
    keywordsImpedance (Electricity)
    keywordsWaves
    keywordsBiological tissues
    keywordsDesign
    keywordsVisualization
    keywordsPhysiology
    keywordsElectrodes
    keywordsStatistical analysis
    keywordsBlood
    keywordsParticle spin AND Product design
    treeJournal of Biomechanical Engineering:;2005:;volume( 127 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian